4.28.2 Setup Master IndicatorSet the following parameters on the master indicator:llllP290 - Choose the communication port of the master indicator the remoteindicator is connected to.P291 - Transmit any ASCII character or control code to the remote indicatoras a start character before echoing unit's display. Make sure this parametermatches P274 on the remote indicator.P292 - Transmit any ASCII character or control code to the remote indicatoras an ending character after echoing unit's display. Make sure thisparameter matches P275 on the remote indicator.P296 - Choose the remote indicator type, a 300 series or 60 series.4.28.3 Setup Remote IndicatorParameterSettingDisplayedNameFor an indicator to become a remote display P260 must be set for r-dsp. There are twostyles in which the remote indicator will display data received from the master indicator.These styles are display and custom. Choose one of the display styles at P271. Referto page 112 for details on display and custom styles.The parameters in the following table are available only when P260 is set for r-dsp orHub.Table 4.4 Remote Display Setup ParametersDescriptionP261.01 R-port Choose the port in which the remote display (slave) will communicate with themaster device.P270.00 T-out Determines whether the remote display (slave) will show a message whenconnection is lost.P271.00 Style Set to display or custom. When set to display the remote will echo the display of themaster indicator. When set to custom the remote receives a custom format from themaster indicator. In custom mode the transmit may be send continuous or ondemand.Type / choices(*=Default)1*, 2, NoneEnable / Disable*Display* / CustomP272.00 Addr Set address for remote display. Only present if P271 is set for custom. None*, 1-255P273.01 T-use Determines where transmits sent out the comm. port from the master or controlindicator that is connected to the remote or hub are redirected to. Should not be setto the same port as P261 unless transmit wire is being used to connect to a printerconnected to the remote indicator (In this case the keypad cannot be used to talk tothe master or control indicator).P274.02 Start Set the start character for the remote display. Choices are 0 - 255. Default value is2 (STX). The choice must match the start character in P291 on the master display.Avoid using values of 17 or 19 when using software flow control. The values of 17and 19 are Xon and Xoff codes and could cause conflict.P275.03 End Set the end character for the remote display. Choices are 0 - 255. Default value is 3(ETX). The choice must match the end character in P292 on the master display.Avoid using values of 17 or 19 when using software flow control. The values of 17and 19 are Xon and Xoff codes and could cause conflict.P276.01 Rptin Allow or disallow data received from the remote display's (slave) communicationport to be sent to the master.None*, Port 1, Port2Numeric Entry:0 to 255 2*Numeric Entry:0 to 255 3*Enable* / DisableModel 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong> 109

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!