GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...
GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...
GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ParameterSettingDisplayedNameDescriptionP173.-- AnlFS Full scale value at which P172 selection yields an output of 10 volts. Ifset to 0, uses P110 setting.Numeric Entry:0* to± 1,000,000P174.-- AnOff Offset value which yields a 0 volt output. Numeric Entry:0* to± 1,000,000P175.10 AnRng Range Value (1-10) which specifies the max value of analog output -entered in terms of voltage. NOTE: This does not change the analogspan. A 0-10,000 lb. output set to 8 will stop increasing its analogsignal at 8,000 lbs.P176.01 AnRst Reset state - Specifies analog signal level when Model 350 I.S. andModel 355 I.S. enters Setup Mode.Type/choices(*=Default)Numeric entry:0 to10*10 V (Max Output)0 V (Min Output)No Change*P177.00 AType Specifies output type: voltage or current. 0 -10 volts*,0 -20mA,4 -20mAThe actual output signal is calculated as follows:If the result is greater than the Max Range Value (P175), then the analog signal islimited to the Max Range Value.4.27.1 Analog Output CalibrationParameterSettingDisplayedNameDescriptionType/Choices (*=default)P61200 10oFF Value required to precisely output 0V in Numeric Entry: 0 to 15,000 (2,923*)0 - 10V output mode (i.e. offset).P61201 10Gn Value required to precisely output 10V in Numeric Entry: 50,000 to 65,535 (61,027*)0 - 10V output mode (i.e. gain).P61202 0oFF Value required to precisely output 0 mANot adjustable: (0*)in 0 - 20 mA output mode (i.e. offset).P61203 0Gn Value required to precisely output 20 mA Numeric Entry: 50,000 to 65,535 (54,555*)in 0 - 20mA output mode (i.e. gain).P61204 4oFF Value required to precisely output 0 mA Numeric Entry: 0 to 15,000 (10,910*)in 4 - 20 mA output mode (i.e. offset).P61205 4Gn Value required to precisely output 20 mA Numeric Entry: 50,000 to 65,535 (54,555*)in 4 - 20mA output mode (i.e. gain).P61206 Srln Analog option board serial number. Numeric Entry:(0*) - 4,294,967,295Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong> 105