11.07.2015 Views

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

GSE 350IS / GSE 355IS Service Manual - Advanced Weigh ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Figure 4.6 Target Above ToleranceNOTE: (bargraph for filling and emptying modes)For modes other than check-weighing, the bars will be on only while the setpoints areon and during the "Done" at the end of a fill.The bar weights will be calculated similar to the check-weigh modes of operationstated above for filling, batching, etc., except that the percentage will be based on theactual target, rather than the low-limit value (see the equation below). The operationfor emptying (and the emptying portion of 'both') will be the same except that theweight will be going negative while the left side bars are turning off.Although the setpoint annunciators are not motion-inhibited, the setpoint relay outputswill not activate until a no-motion condition exists.4.27 Analog Output SetupParameterSettingDisplayedNameRefer to the table below for parameter to setup the analog output.DescriptionType/choices(*=Default)P171.00 AnAlg Enable analog option. Disbl*, EnablP172.00 AnPar Parameter that analog signal corresponds to. Displayed correspondsto gross while viewing the gross weight and net otherwise.Gross*, Net,Displayed104Model 350 I.S. and Model 355 I.S. <strong>Service</strong> <strong>Manual</strong>