11.07.2015 Views

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Analogue/digital input valueValue on the analogue/digital input as a percentage of theinput range. This read-out depends on the configuration ofthe analogue/digital input in menu [500], e.g. if the analogue/digitalinput is configured for analogue start/stop0-10 V/0-20 mA (alternative 6), an input signal of 4 V or8 mA will be shown as 40%. However, if the analogue/digitalinput is configured for analogue start/stop 2.10 V/4-20mA (alternative 7), an input signal of 4 V or 8 mA will beshown as 25%.7 2 3Range: 0-100%Analogue/digital input valueRelay statusStatus of the relays K1 to K3 from the left to the right. L orH are displayed for relay status low (opened) or high(closed). The status described for relay K3 corresponds tothe status of terminals 31 and 32.7 2 4Range:0LLL-HHHRelay statusRead-outAnalogue Output valueValue on the analogue output as a percentage of the outputrange. This read-out depends on the configuration of theanalogue output in menu [520], e.g. if the analogue/digitalinput is configured for 0-10 V/0-20 mA (alternative 1) orfor 10-0 V/20-0 mA (alternative 3), an output signal of 4 Vor 8 mA will be shown as 40%. However, if the analogueoutput is configured for 2-10 V/4-20 mA (alternative 2) or10-2 V/20-4 mA (alternative 4), an output signal of 4 V or8 mA will be shown as 25%.7 2 5LLLRead-outRead-out8.10.3 Stored valuesOperation time. The operation time is the time duringwhich the motor connected to the softstarter is running, notthe time during which the supply power is on.If the actual value for the operation time exceeds 9999 hoursthe display will alternate between the four lower digits andthe higher digits.ExampleIf the actual operation time is 12467, 1 will be shown for1 s, then 2467 will be shown for 5 s and so on.7 30Range:0-9 999 999 hEnergy consumption7 3 1Range:Operation time0.000-2000 MWhEnergy consumptionReset energy consumptionIn this menu the stored power consumption (menu [713])can be reset to 0.Default:Range:noYES00. 0 0 07 32n oReset energy consumptionnono, YESNo actionReset power consumptionRead-outRead-outMulti Setting0Analogue Output valueRange: 0-100%<strong>Emotron</strong> AB 01-4135-01r2 Functional description 95

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!