11.07.2015 Views

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Undervoltage level [437]This menu is available if undervoltage alarm is enabled inmenu [436]. In this menu the voltage level for an undervoltagealarm is selected. If any line voltage is below the chosenlevel for the response delay time set in menu [438], an undervoltagealarm will occur and the action selected in menu[436] will be executed.4 3 785Default: 85%Range: 75-100% of U n75-100 Undervoltage levelUndervoltage levelSettingResponse delay undervoltage alarm[438]This menu is available if undervoltage alarm is enabled inmenu [436]. In this menu the response delay for undervoltagealarm is selected. If any line voltage is below the level setin menu [437] for the chosen response delay time, an undervoltagealarm will occur and the action selected in menu[436] will be executed.Phase reversal alarm [440]In this menu phase reversal alarm is enabled and a properaction can be chosen. The softstarter will detect the phasesequence prior to each start attempt. If the actual phasesequence does not match the phase sequence stored duringactivation of phase reversal alarm, the action chosen in thismenu will be executed. If alternative 2 (Coast) is chosen, nostart will be performed if the wrong phase sequence isdetected.To activate phase reversal alarm, a motor has to be connectedand the mains voltage has to be switched on. Thismeans activation of phase reversal alarm can either be donein stopped state with the mains contactor switched on manuallyor during full voltage running.4 4 0oFFPhase reversal alarm (alarmcode F16)Default: oFFRange: oFF, 1, 2oFFPhase reversal alarm is disabled.1 Warning2 CoastSetting4 3 8SettingNOTE! The actual phase sequence can be viewed inmenu [439].1Response delay undervoltagealarmDefault: 1 sRange: 1-90 s1-90 Response delay for undervoltage alarmPhase sequence [439]In this menu the actual phase sequence is shown.NOTE! The actual phase sequence can only be shownwith a motor connected.4 3 9Read-outL - - -Phase sequenceRange: L123, L321L123 Phase sequence L1, L2, L3L321 Phase sequence L3, L2, L1L- - - Phase sequence can not be detected76 Functional description <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!