Unbalance voltage level [431]This menu is available if voltage unbalance alarm is enabledin menu [430]. In this menu the maximum allowed voltageunbalance level is selected. If the difference between any twoline voltages exceeds the chosen level for the response delaytime set in menu [432], a voltage unbalance alarm will occurand the action selected in menu [430] will be executed.Overvoltage level [434]This menu is available if overvoltage alarm is enabled inmenu [433]. In this menu the voltage level for an overvoltagealarm is selected. If any line voltage exceeds the chosenlevel for the response delay time set in menu [435], an overvoltagealarm will occur and the action selected in menu[433] will be executed.4 3 1Setting4 3 4Setting10Voltage unbalance levelDefault: 10%Range: 2-25% of U n2-25 Voltage unbalance level.Response delay voltage levelunbalance alarm [432]This menu is available if voltage unbalance alarm is enabledin menu [430]. In this menu the response delay for voltageunbalance alarm is selected. If the difference between anytwo line voltages exceeds the level set in menu [431] for thechosen response delay time, a voltage unbalance alarm willoccur and the action selected in menu [430] will be executed.4 3 21Response delay voltageunbalance alarmDefault: 1 sRange: 1-90 s1-90 Response delay for voltage unbalance alarm.Overvoltage alarm [433]In this menu overvoltage alarm is enabled and a properaction is selected.4 3 3oFFOvervoltage alarm (alarm codeF9)Default: oFFRange: oFF, 1, 2, 3, 4oFFOvervoltage alarm is disabled.1 Warning2 Coast3 Stop4 Alarm BrakeSettingSetting1Default: 115%Range: 100-150% of U n100-150 Overvoltage levelOvervoltage levelResponse delay overvoltage alarm[435]This menu is available if overvoltage alarm is enabled inmenu [433]. In this menu the response delay for overvoltagealarm is selected. If any line voltage exceeds the level set inmenu [434] for the chosen response delay time, an overvoltagealarm will occur and the action selected in menu [433]will be executed.4 3 515Response delay overvoltagealarmDefault: 1 sRange: 1-90 s1-90 Response delay for overvoltage alarm.Undervoltage alarm [436]In this menu undervoltage alarm is enabled and a properaction is selected.4 3 6oF1FUndervoltage alarm (alarm codeF10)Default: oFFRange: oFF, 1, 2, 3, 4oFFUndervoltage alarm is disabled.1 Warning2 Coast3 Stop4 Alarm BrakeSettingSetting<strong>Emotron</strong> AB 01-4135-01r2 Functional description 75

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!