Max power pre-alarm margin [405]This menu is available if max power alarm is enabled inmenu [400]. In this menu the max power pre-alarm marginis configured. The margin is selected in percent of nominalmotor power. A max power pre-alarm will occur if the actualmotor shaft power exceeds the normal load (menu [412])plus the chosen max power pre-alarm margin for a longertime period than the max power pre-alarm response delay setin menu [406]. The max power pre-alarm status is availableon one of the programmable relays K1-K3 if so configured(see description of the relays, menus [530] to [532] for moreinformation).4 0 58Max power pre-alarm marginDefault: 8%Range: 0-100% of P n0-100 Max power pre-alarm margin.SettingMax power pre-alarm response delay[406]This menu is available if max power alarm is enabled inmenu [400]. In this menu the response delay for max powerpre-alarm is configured. A max power pre-alarm will occur ifthe actual motor shaft power exceeds the normal load (menu[412]) plus the max power pre-alarm margin set in menu[405] for a longer time period than the chosen max powerpre-alarm response delay.4 0 60.5SettingMax power pre-alarm responsedelayDefault: 0.5 sRange: 0.1-90.0 s0.1-90.0 Response delay for Max power pre-alarm.Min power pre-alarm margin [407]This menu is available if min power alarm is enabled inmenu [401]. In this menu the min power pre-alarm marginis configured. The margin is selected as a percentage of nominalmotor power. A min power pre-alarm will occur if theactual motor load is below the nominal load (menu [412])minus the chosen min power pre-alarm margin for a longertime period than the min power pre-alarm response delay setin menu [408]. The min power pre-alarm status is availableon one of the programmable relays K2-K3 if so configured(see description of the relays, menus [530] to [532] for moreinformation.4 0 7Min power pre-alarm marginDefault: 8%Range: 0-100% of P n0-100 Min power pre-alarm margin.Min power pre-alarm response delay[408]This menu is available if min power alarm is enabled inmenu [401]. In this menu the response delay for min powerpre-alarm is configured. A min power pre-alarm will occur ifthe actual motor shaft power is below the normal load(menu [412]) minus the min power pre-alarm margin set inmenu [407] for a longer time period than the chosen minpower pre-alarm response delay.4 0 8Min power pre-alarm responsedelayDefault: 0.5 sRange: 0.1-90.0 s0.1-90.0 Response delay for Min power pre-alarm.Min power alarm margin [409]This menu is available if min power alarm is enabled inmenu [401]. In this menu the min power alarm margin isconfigured. The margin is selected as a percentage of nominalmotor power. A min power alarm will occur if the actualmotor shaft power is below the normal load (menu [412])minus the chosen min power alarm margin for a longer timeperiod than the min power alarm response delay set in menu[410].4 0 90.1856Min power alarm marginDefault: 16%Range: 0-100% of P n0-100 Min power alarm margin.SettingSettingSetting72 Functional description <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!