11.07.2015 Views

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

To optimize the start, use the setting for initial torque atstart, menu [311] and end torque at start, menu [312].When the start command is given, the motor shaft shouldimmediately start to rotate to avoid unnecessary heat developmentin the motor. If required, increase the initial torqueat start.The end torque at start should be adjusted so that the timefor the motor to come up to nominal speed approximatelymatches the start time set in menu [315]. If the actual starttime is much shorter than the set start time in menu [315],the End torque at start can be decreased. If the motor doesnot reach full speed before the start time set in menu [315]has expired, the end torque at start has to be increased toavoid current peaks and jerking at the end of the ramp. Thismay be needed for high inertia loads such as planers, sawsand centrifuges.The read-out of shaft torque in percentage of T n in menu[706] may be useful for fine-tuning the start ramp.VoltageU nStartFig. 39 Menu numbers for initial voltage and start time.TimeInitial voltage at start [313]This menu is available if voltage control is chosen as startmethod in menu [310]. In this menu the initial voltage atstart is set.Initial torque at start [311]This menu is available if torque control is selected in menu[310]. In this menu the initial torque at start is set.3 1 3Setting3 1 1Initial torque at startDefault: 10%Range: 0-250% T n0-250 Initial torque at start.End torque at start [312]This menu is available if torque control is selected in menu[310]. In this menu the end torque at start is set.3 1 210SettingSetting30Initial voltage at startDefault: 30%Range: 25-90% U25-90 Sets initial voltage at start.Direct on-line, DOLIf this alternative is selected in menu [310], the motor canbe accelerated as if it was connected directly to the mains.For this type of operation:Check whether the motor can accelerate the required load(DOL start). This function can also be used with shortedthyristors.150End torque at start6-7 x I nomTimeDefault: 150%Range:25-250% T n25-250 End torque at start.Voltage controlVoltage control can be used when a linear voltage ramp isdesired. The voltage to the motor will be ramped up linearly,from initial voltage up to full mains voltage.FLCFig. 40 DOL-start.58 Functional description <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!