Nominal motor speed.2 1 314Nominal motor power factor.Nominal motor frequencyNominal motor speedDefault: N nsoft in rpmRange: 500-3600 rpm500-3600 Nominal motor speed.2 1 4Nominal power factorDefault: 0.86Range: 0.50-1.000.50-1.00 Nominal motor power factor.2 1 50.508650Nominal frequencyDefault: 50 HzRange: 50 Hz, 60 Hz50, 60 Nominal frequency.SettingSettingSetting8.3 Motor protectionThe <strong>MSF</strong> <strong>2.0</strong> softstarter is equipped with different motorprotection functions. The following menus are available toconfigure these protection methods:[220]-[223] Thermal motor protection[224]-[227] Start limitation[228]-[229] Locked rotor[230] Single phase input failure[231] Current limit start time expiredFor these protection methods the following options areavailable (all options may not be available for all protectionmethods – check the description of the relevant menu fordetails):OffThe protection method is disabled.WarningThe appropriate alarm message is shown in the display andrelay K3 is activated (for default configuration of the relays).However, the motor is not stopped and operation continues.The alarm message will disappear and the relay will be resetwen the fault disappears. The alarm may also be reset manually.CoastThe appropriate alarm message is shown in the display andrelay K3 is activated (for default configuration of the relays).The motor voltage is automatically switched off. The motorfreewheels until it stops.StopThe appropriate alarm message is shown in the display andrelay K3 is activated (for default configuration of the relays).The motor is stopped according to the stop settings inmenus [320] to [325].Alarm BrakeThe appropriate alarm message is shown in the display andrelay K3 is activated (for default configuration of the relays).The brake function is activated according to the brakingmethod chosen in menu [323] and the motor is stoppedaccording to the alarm brake settings in menus [326] to[327] (braking strength and braking time).8.3.1 Thermal motor protectionWith <strong>MSF</strong> <strong>2.0</strong> an internal thermal model of the motor or anexternal signal from a PTC can be used for thermal motorprotection. It is also possible to combine both protectionmethods. Slight overload for a long time and several overloadsof short duration will be detected with both methods.Thermal motor protection [220]Thermal motor protection is activated by choosing an alarmaction in menu [220]. After that menus [221] to [223] willbe available so that the type of the protection (internal and/or PTC) can be chosen. If the operation has been interrupteddue to a thermal motor protection alarm, a manualreset and a new start signal is needed to restart the motor.The reset and the start signal can be given via control panel,remote or via serial communication depending on the controlsource chosen in menu [200]. Regardless of the chosencontrol source, it is always possible to initiate a reset via thecontrol panel.NOTE: A reset via the control panel will never start themotor.46 Functional description <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!