Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8.1 General settingsGeneral settings for <strong>MSF</strong> <strong>2.0</strong> contains the following menus:[100] Current[101] Automatic return menu[200] Control source[201] Control panel locked for settings[202] Enable US units8.1.1 Current [100]This read-out menu shows the actual current to the motor.1 0 0Range:0. 00.0-9999ACurrentNOTE! This is the same read-out as menu [700].8.1.2 Automatic return menu [101]When the <strong>MSF</strong> <strong>2.0</strong> is powered up, menu [100] (Currentread-out) is shown as default. When another menu has beenselected by the user (moving through the menu list with the“NEXT” or “PREV” keys) this menu will remain active.Alternatively a specific menu can be chosen as automaticreturn menu. The chosen menu will be shown automaticallyafter 60 seconds without any control panel activity.1 0 1o F FAutomatic return menuDefault: oFFRange: oFF, 1-999oFFAutomatic return menu is disabled.1-999 Automatic return menu.Read-outSetting8.1.3 Control source [200]The softstarter can be controlled either via the control panel,remote control or the serial communication interface.Remote control via terminals 11,12 and 13 is the default setting.NOTE: Depending on the setting in this menu, thesoftstarter may be configured via control panel or viaserial communication. See Table 14, page 42 for moreinformation.NOTE: If control panel (1) or remote control (2) isconfigured, the setting can only be changed via controlpanel to serial communication control (3). However, ifserial communication control (3) is configured, thesetting can be changed either via serial communicationor via control panel.2 0 0Control sourceDefault: 2 (remote control)Range: 1, 2, 31 Control panel.2 Remote control.3 Serial communication control.8.1.4 Control panel lock [201]The <strong>MSF</strong> <strong>2.0</strong> Control panel can be locked to preventparameter being set by unauthorised personnel.• Lock control panel by simultaneously pressing both keys“NEXT ” and “ENTER ” for at least 2 seconds.The message “- Loc” will be displayed for 2 seconds.• To unlock control panel, simultaneously press the sametwo keys “NEXT ” and “ENTER ” for at least 2seconds. The message “unlo” will be displayed for 2 seconds.In locked mode, all parameters and read-out menus can bedisplayed, but it is forbidden to change any parameters viathe control panel.The message “-Loc” will be displayed if someone tries to seta parameter in locked mode.The key lock status can be read out in menu [201].NOTE: If parameter [200] is configured for serialcommunication control, the softstarter may still beconfigured via serial communication, regardless of thecontrol panel lock status.2 01oDefault:Range:noYES2F FControl panel locked forsettingsnooFF, onControl panel is not lockedControl panel is lockedSettingRead-out44 Functional description <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!