Emotron MSF 2.0 Softstarter

Emotron MSF 2.0 Softstarter Emotron MSF 2.0 Softstarter

11.07.2015 Views

14. Set-up menu listTable 27Parameter listMenuno.Function / ParameterRange /SettingsFactorysettingCustomer setting / Parameter set 1-41 2 3 4PageGENERAL SETTINGS100 Current 0.0 - 9999 A Read-out 44101 Automatic return menu oFF, 1 - 999 oFF 44200 Control source201Control panel locked for settings1. Control panel2. Remote control3. Serial comm. controloFF, on2 44oFF /Read-out202 Enable US-units oFF, on oFF 45MOTOR DATA210 Nominal motor voltage 200 - 700 V 400 45211 Nominal motor current 25 - 200 % of I nsoft in A I nsoft 45212 Nominal motor power25 - 400 % of P nsoft in kW orPhpnsoft 45213 Nominal motor speed 500 - 3600 rpm n nsoft 46214 Nominal motor power factor 0.50 - 1.00 0.86 46215 Nominal frequency 50, 60 Hz 50 46MOTOR PROTECTIONThermal motor protection220Thermal motor protection(alarm code F2)oFF. Disabled1. Warning2. Coast3. Stop4. Alarm brake442 46221 PTC input oFF, on oFF 47222 Internal protection class oFF, 2 - 40 s 10 47223 Used thermal capacity 0 - 150 % Read-out 47Start limitation224Start limitation (Alarm codeF11)oFF. Disabled1. Warning2. CoastoFF 48225 Number of starts per hour oFF, 1 - 99 oFF 49226 Min. time between starts oFF, 1 - 60 min oFF 49227 Time to next allowed start 0 - 60 min Read-out 49Locked rotor228Locked rotor alarm (Alarmcode F5)oFF. Disabled1. Warning2. CoastoFF 49229 Locked rotor time 1.0 - 10.0 s 5.0 49230Single phase input failure(Alarm code F1)1. Warning2. Coast2 50Emotron AB 01-4135-01r2 Set-up menu list 123

Table 27Parameter listMenuno.Function / ParameterRange /SettingsFactorysettingCustomer setting / Parameter set 1-41 2 3 4Page231Current limit start timeexpired (Alarm code F4)PARAMETER SET HANDLING240 Select parameter setoFF. Disabled1. Warning2. Coast3. Stop4. Alarm brake241 Actual parameter set 1, 2, 3, 40. External control of parametersets1-4. Selection of parametersets 1-42 501 511 /Read-outno, 1-2, 1-3, 1-4, 2-1, 2-3, 2-242 Copy parameter setno 514, 3-1, 3-2, 3-4, 4-1, 4-2, 4-3243 Reset to factory setting no, YES no 52AUTO RESET250 Auto reset attempts oFF, 1 - 10 oFF 52251Thermal motor protectionauto resetoFF, 1 - 3600 s oFF 53252 Start limitation auto reset oFF, 1 - 3600 s oFF 53253 Locked rotor alarm auto reset oFF, 1 - 3600 s oFF 53254Current limit start timeexpired auto resetoFF, 1 - 3600 s oFF 53255 Max power alarm auto reset oFF, 1 - 3600 s oFF 53256 Min power alarm auto reset oFF, 1 - 3600 s oFF 53257 External alarm auto reset oFF, 1 - 3600 s oFF 54258 Phase input failure auto reset oFF, 1 - 3600 s oFF 54Voltage unbalance alarm259oFF, 1 - 3600 s oFF 54auto reset260 Over voltage alarm auto reset oFF, 1 - 3600 s oFF 54261262Under voltage alarm autoresetSerial communication autoresetoFF, 1 - 3600 s oFF 54oFF, 1 - 3600 s oFF 54263Softstarter overheated autoresetoFF, 1 - 3600 s oFF 54SERIAL COMMUNICATION270 Serial comm. unit adress 1 - 247 1 54271 Serial comm. baudrate 2.4 - 38.4 kBaud 9.6 55272 Serial comm. parity273Serial comm. contact broken(Alarm code F15)0. No parity1. Even parityoFF. Disabled1. Warning2. Coast3. Stop4. Alarm brake0 553 5551124 Set-up menu list Emotron AB 01-4135-01r2

Table 27Parameter listMenuno.Function / ParameterRange /SettingsFactorysettingCustomer setting / Parameter set 1-41 2 3 4Page231Current limit start timeexpired (Alarm code F4)PARAMETER SET HANDLING240 Select parameter setoFF. Disabled1. Warning2. Coast3. Stop4. Alarm brake241 Actual parameter set 1, 2, 3, 40. External control of parametersets1-4. Selection of parametersets 1-42 501 511 /Read-outno, 1-2, 1-3, 1-4, 2-1, 2-3, 2-242 Copy parameter setno 514, 3-1, 3-2, 3-4, 4-1, 4-2, 4-3243 Reset to factory setting no, YES no 52AUTO RESET250 Auto reset attempts oFF, 1 - 10 oFF 52251Thermal motor protectionauto resetoFF, 1 - 3600 s oFF 53252 Start limitation auto reset oFF, 1 - 3600 s oFF 53253 Locked rotor alarm auto reset oFF, 1 - 3600 s oFF 53254Current limit start timeexpired auto resetoFF, 1 - 3600 s oFF 53255 Max power alarm auto reset oFF, 1 - 3600 s oFF 53256 Min power alarm auto reset oFF, 1 - 3600 s oFF 53257 External alarm auto reset oFF, 1 - 3600 s oFF 54258 Phase input failure auto reset oFF, 1 - 3600 s oFF 54Voltage unbalance alarm259oFF, 1 - 3600 s oFF 54auto reset260 Over voltage alarm auto reset oFF, 1 - 3600 s oFF 54261262Under voltage alarm autoresetSerial communication autoresetoFF, 1 - 3600 s oFF 54oFF, 1 - 3600 s oFF 54263<strong>Softstarter</strong> overheated autoresetoFF, 1 - 3600 s oFF 54SERIAL COMMUNICATION270 Serial comm. unit adress 1 - 247 1 54271 Serial comm. baudrate 2.4 - 38.4 kBaud 9.6 55272 Serial comm. parity273Serial comm. contact broken(Alarm code F15)0. No parity1. Even parityoFF. Disabled1. Warning2. Coast3. Stop4. Alarm brake0 553 5551124 Set-up menu list <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!