Observation Fault indication Cause SolutionF9(Overvoltage)F10(Undervoltage)Mains supply overvoltage.Check mains supply.Mains supply undervoltage.Check mains supply.The motor does notrun.F11(Start limitation)F13(Open thyristor)F14(Motor terminal open)Number of starts per hourexceeded, min time betweenstarts not kept.Perhaps a damaged thyristor.Open motor contact, cable ormotor winding.Wait and start again.Perhaps the number of starts perhour could be increased in menu[225] or the min time between startscould be decreased (menu [226]).Initiate a reset and a restart. If thesame alarm appears immediately,contact your local <strong>MSF</strong> sales outlet.If the fault is not found, reset thealarm and inspect the alarm list. Ifalarm F12 is found, a thyristor isprobably shorted.Initiate a restart. If alarm F14appears immediately, contact yourlocal <strong>MSF</strong> sales outlet.F15(Serial communication contactbroken)Serial communication contact broken.Initiate a reset and try to establishcontact. Check contacts, cables andoption board.Verify- Serial communication unit address[270].- Baudrate menu [271].- Parity menu [272].If the fault is not found, run themotor from the control panel ifurgent set parameter [200] to 1. Seealso manual for serial communication.F16(Phase reversal)Incorrect phase sequence onmain supply.Switch L2 and L3 input phases.F17 (External alarm)External alarm signal input openCheck the digital input configured forExternal alarm. Check the configurationof the digital inputs (menus[510] to [513]).- - - -Start command comes perhapsfrom incorrect control source. (I.e.start from control panel whenremote control is selected).Give start command from correctcontrol source as configured in menu[200].The motor is runningbut an alarm isgiven.F1(Phase input failure)F4(Current limit start timeexpired)Failure in one phase.Perhaps fuse is defective.Current limit parameters are perhapsnot matched to the load andmotor.Check fuses and mains supply.Select a different alarm action forSingle phase input failure in menu[230] if stop is desired at singlephase loss.Increase the start time (menu [315])and/or the current limit at start(menu [314]). Select a differentaction for Current limit start timeexpired alarm in menu [231], if stopis desired at current limit time-out.102 Troubleshooting <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!