whether they need a Reset signal (manual reset) or if they arereset automatically when a new start signal is given.An alarm can always be reset by giving a Reset signal, even ifthe failure that caused the alarm has not disappeared yet.Giving a Reset will cause the alarm message on the display todisappear and the alarm relay K3 to be deactivated (fordefault configuration of the relays). However, if operationhas been interrupted due to an alarm, a Restart will not bepossible until the failure has disappeared. If a new start signalis given while the failure still is active, the alarm messagewill appear flashing in the display and the alarm relay K3will be activated again (for default configuration of therelays).<strong>MSF</strong> <strong>2.0</strong> is also provided with an Auto reset function. Thisfunctionality is described in detail in section 8.5, page 52.9.4 Alarm overviewTable 17Alarm overviewF1F2AlarmcodeAlarm description Alarm action Protection system ResetPhase input failure.Thermal motor protectionWarningCoastOffWarningCoastStopAlarm BrakeMotor protection(menu [230])Motor protection(menu [220])Automatic Reset when new start signal isgiven.Separate Reset signal needed.F3 Soft start overheated Coast Separate Reset signal needed.F4F5F6F7F8F9F10Current limit start timeexpired.Locked rotor alarm.Max power alarm.Min power alarm.Voltage unbalancealarm.Overvoltage alarm.Undervoltage alarm.OffWarningCoastStopAlarm BrakeOffWarningCoastOffWarningCoastStopAlarm BrakeOffWarningCoastStopAlarm BrakeOffWarningCoastStopAlarm BrakeOffWarningCoastStopAlarm BrakeOffWarningCoastStopAlarm BrakeMotor protection(menu [231])Motor protection(menu [228])Process protection(menu [400])Process protection(menu [401])Process protection(menu [430])Process protection(menu [433])Process protection(menu [436])Automatic Reset when new start signal isgiven.Separate Reset signal needed.Separate Reset signal needed.Separate Reset signal needed.Automatic Reset when new start signal isgiven.Automatic Reset when new start signal isgiven.Automatic Reset when new start signal isgiven.98 Protection and alarm <strong>Emotron</strong> AB 01-4135-01r2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!