AIR CONDITIONING SYSTEMSCM07WD4-B


Our Latest TechnologiesV RF systemVRF stands for Variable Refrigerant Flow.A VRF air conditioning system modulates theflow of refrigerant depending upon the capacityrequirements of the building. A VRF system<strong>com</strong>prises of condensing unit sited externallyI ntelligent Power Module (IPM)technologyand a series of multiple heating to theoccupied space.The <strong>City</strong> <strong>Multi</strong> range from Mitsubishi Electricprovides precise control of energy input,through utilization of Intelligent Power Module(IPM) technology. Employing this technology itI nverter driven technologyis possible to closely match the buildingrequirements, achieving more accurate controlAir conditioning is an ideal way ofcontrolling the temperature, movementand cleanliness of air inside anybuilding, large or small. With today'sbuildings being so well insulated andincreasingly full of electronic equipment,the need for effective climate control isgreater than ever. Not only does it coolin the summer months, but air conditioningcan also heat, doing away with theneed for separate heating systemsaltogether. More and more people todayare enjoying the benefits of <strong>com</strong>fortableUnsurpassed air conditioningfrom Mitsubishi ElectricKnown the world over, the nameMitsubishi is a trusted household nameassociated with a variety of productsand services. Founded in 1907, the<strong>com</strong>pany known today as MitsubishiElectric, quickly rose to the forefront ofAt Mitsubishi Electric we strive to continuallymeet the increasing demands of our customers,being the first in the industry to offer highlyadvanced ‘inverter driven’ systems. Usinginverter technology our systems produce justthe right amount of output to match the exactrequirement of any building. These systemswork so efficiently that they don’t wastevaluable energy by over-heating or overcooling,resulting in greatly reduced runningcosts. Alternative systems that may appearcheaper, can often cost substantially more torun, making us the most cost effective choiceall round.of the occupied space. By using incremental1Hz steps of capacity control, the amount ofpower input required is significantly reduced,resulting in greatly improved COP’s.R 410A refrigerantAs scientific evidence points to man-madechemicals for the damage caused to the ozonelayer, we only use chlorine-free refrigerantsthat are safe and have ‘zero ozone depletionpotential’. Accordingly, as our systems requireless energy to run, they have a significantlylower indirect global warming potential too. Inshort, our constant investment and productdevelopment possible, whilst protecting theenvironment at the same time.working and living environments madethe air conditioning industry - a positionpossible with air conditioning.we still enjoy today. We pride ourselveson offering some of the most energyefficient systems available on themarket.Page 1 Page 2


V RF systemOur answer to VRFMitsubishi Electric sets the boundaries of VRF technology with the <strong>City</strong> <strong>Multi</strong> range, which is available usingR410A refrigerant with zero ODP (Ozone Depletion Potential). The range has been specifically designed fortoday’s building requirements and addresses key market issues such as energy efficiency, adaptability andreliability. With user friendly control systems utilizing Internet technology and integrated cooling and ventilationindoor units, <strong>City</strong> <strong>Multi</strong> is the benchmark and market leader in VRF technology.VRF is a multi and direct expansion type air conditioning system that one outdoor unit can be connected withmultiples of indoor units. The amount of refrigerant can be changed freely according to the load in the indoor unitbecause inverter <strong>com</strong>pressor is used in the outdoor unit. Zoning in a small office is possible with a small capacityindoor unit. Energy conservation is easily handled because individual indoor unit can stop and start its operationas needed. Indoor unit has a lot of models in order to suit various interior design needs. Appliance to controlseparating heat of cooling in evaporation from heat in condensation is be<strong>com</strong>ing important in air conditioning in thebuilding.Sophisticatedyet simple technologyInverter driven <strong>com</strong>pressorReliableOutdoor unitJointHeaderDesigned and manufactured to the highest standards, the<strong>City</strong> <strong>Multi</strong> range offers one of the most reliable airconditioning systems available. Simple to install and easy tomaintain, this range provides ideal solutions you can trust toprotect your investment.PEFY-VMSIndoor unitON 27˚cON 25˚cON 25˚cOFFOFFON 23˚cON 26˚cPEFY-VMRController>All the <strong>City</strong> <strong>Multi</strong> outdoor units are made in Japan under stringent control.PFFY-VKMPage 3 Page 4


I nverter Driven CompressorTechnology - now up to 50HPLowStartingCurrentsUsing inverter driven technologysaves energy for several reasons:Unbeatable EfficiencyHeat Interchange CircuitThe unique Heat Interchange Circuit (HIC) enhances efficiency by providing additional sub-cooling and allows theexpansion device to control more effectively the refrigerant distribution, thereby increasing the operating efficiencyand reducing the volume of refrigerant in each system.<strong>City</strong> <strong>Multi</strong> Refrigerant CircuitCompressorCondenserAccumulatorHeat exchangerHigh temperatureBypassSupercooledheat exchangerLow temperatureElectric expansion valveMedium temperatureCommon Refrigerant CircuitCompressorCondenserAccumulatorExpansionvalveThe <strong>com</strong>pressor varies its speed to match the indoor cooling or heating demand and therefore only consumes theenergy that is required.When an inverter driven system is operating at partial load, the energyefficiency of the system is significantly higher than that of astandard fixed speed, non inverter system.The fixed speed system can only operate at 100%, andpartial load conditions prevail for the majority of the time.Therefore fixed speed systems cannot match the annualefficiencies of inverter driven systems.100%Using proven single inverter driven <strong>com</strong>pressortechnology, the <strong>City</strong> <strong>Multi</strong> range is favoured by theindustry for low starting currents (only 15 amps for a16HP YHM-A outdoor unit), a smooth transition acrossthe range of <strong>com</strong>pressor frequencies and foreliminating systems.15%Heating / Cooling CapacityLinear CapacityControl15Hz>All the <strong>City</strong> <strong>Multi</strong> <strong>com</strong>pressors are inverter-driven type (4~50HP).Compressor FrequencyCooling:97HzHeating:102Hz* imageEvaporatorElectric expansionvalveEvaporatorPage 5 Page 6


I ntelligent Power Module (IPM)TechnologyThe YHM-A range from Mitsubishi Electric provides precise control of energy input, through utilization of IntelligentPower Module (IPM) technology. Employing this technology it is possible to closely match the buildingrequirements, achieving more accurate control of the occupied space. By using incremental 1Hz steps of capacitycontrol, the amount of power input required is significantly reduced, resulting in greatly improved COP’s.In addition, IPM technology ensures effective performance under partial load conditions, a condition that mostsystems will be in for the majority of the normal working life cycle. By taking account the efficiency at both partload, and peak load conditions, R410A <strong>City</strong> <strong>Multi</strong> is designed to provide unbeatable year round/seasonal efficiency.Total Energy ConservationComparison of COP (energy efficiency) – 8HP systemThe difference between YHM-A and previousMitsubishi Electric modelsTechnology is key when increased efficiency is demanded.The <strong>City</strong> <strong>Multi</strong> YHM-A range is able to deliver this in simple ways.A highly efficient R410A scroll <strong>com</strong>pressor design results in less friction losses at the motor. A simplified refrigerantcircuit (low pressure loss) including new accumulator design also adds a few more points to the efficiency scale.Enhancements to the heat interchange circuit, an inverter driven fan motor and a heat exchanger design again addvital increases to overall system efficiency and COP’s.COP5.04.5The importance of COP4.03.53.02.52.02.8729%Energy Saving4.0234%EnergySaving4.33High COP (Coefficient of Performance)is realizedCOP stands for “Co-efficient of performance”. It is a measure of the useful energy a system can deliver <strong>com</strong>paredto the energy it consumes. It is calculated by dividing the energy output by the energy input of a system. Thehigher the figure then the more efficient the system is deemed to be, with <strong>com</strong>mensurate reduced running costs.Mitsubishi Electric VRF models, the world's highest energy-efficient ACs, will undoubtedly reduce millions of tonsof CO2 emissions.0R22Our equivalent product10 years before PUHY-200YMFStandard modelHigh COP model* Average COP of cooling / heatingPage 7 Page 8


E fficient R410A refrigerantHistory of refrigerantR22, an HCFC-based refrigerant, has been a popular choice for most chillers. R22 has been targeted by theMontreal Protocol to be phased out in new equipment. Additionally, the European Union and other countriesgovernments are enforcing a ban of HCFC-based refrigerants for new installations.Because of these restrictions, R410A refrigerants is increasingly available. R410A is a blend of HFCs, which do notdeplete the ozone but may contribute to global warming.Technical aspects of refrigerantFor the EnvironmentR410A is a more efficient refrigerant as it has a higher specific heat capacity when <strong>com</strong>pared to R407C or R22.This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume ofrefrigerant within a system. This is a major factor when <strong>com</strong>plying with ISO5149, an International Organization forStandardization concerning, "safety of persons and property for the design, construction, installation and operationof refrigerating systems".Reduction of operation noiseEnhancing environmental care(measures for the RoHS Directive and the refrigerant reduction)Every unit is in <strong>com</strong>pliance with the RoHS Directive,* which stands for the restriction of hazardous substances:Lead-free soldering is used to avoid Lead Groundwater Contamination on the print board. The amount ofrefrigerant on the unit has also been reduced to enhance environmental care.* RoHS Directive: the restriction of the use of certain hazardous substances in electrical and electronic equipment that has been sold in EU since July 2006Improvement of COPImprovement of COPImprovement of reliability and easy maintenancePage 9 Page 10


Due to the <strong>com</strong>pact design of outdoor unit,industry leading space saving is realized.The downsized outdoor unit can be transportedthrough a 800mm wide door.8-12HP outdoor unitsmm (in.)Example of 6-people lift.mm (in.)1400 (55-1/8)Compact Designof New Outdoor UnitIndustry leading weight saving is realized.The manageability of the outdoor unit has beenimproved due to drastic reduction in unit weight,leading to easy transportation, installation, andreduction in withstand load.10HP outdoor unitAs of September, 2006 (based on internal survey)Approx. 33kgreduction in weightIndustryLeaderHeight1650 1710(64-31/32) (67-3/8)Width920(36-7/32)Depth760(29-29/32)Effective Use of SpaceThe new models have a smaller foot print and servicespace requirement than the R22 models.18HP1740(68-17/32)1510760(59-14/32)950 (37-13/32)450(17-23/32)840(33-1/16)1510(59-14/32)450(17-23/32)1990 (78-11/32)1250 (49-7/32)3.46m 2 1.89m 2Conventional CITY MULTI (YGM series)The unit can easily be transported even into slender buildings.60300(11-26/32)(29-29/32)450(17-23/32)11(14/32") (14/32)10(13/32)800 (31-1/2)1510(59-14/32)Easy totransport10(13/32)1250 (49-7/32)850 (33-15/32)300(11-26/32)760(29-29/32)450(17-23/32)8-12HP systems 14-18HP systems1.43m 2 1.89m 2300(11-26/32)760(29-29/32)450(17-23/32)mm (in.)45%reductionmm (in.)Approx. 233kgApprox. 200kg8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HPWeight(kg) 185 200 215 245 245 245 400 415 445 460 49030HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HPWeight(kg) 490 490 490 490 660 675 705 735 735 735 735The narrow space between buildingsmakes it difficult to use a crane.<strong>City</strong> <strong>Multi</strong>makes it easy.Page 11 Page 12


F eatures and BenefitsNewImprovedFiguresLow Noise LevelsNew Fan Design<strong>City</strong> <strong>Multi</strong> VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantiallylower noise levels over multiple designs. Continuing the development in the areas of blade shape and weight,Mitsubishi Electric have managed to achieve even higher performance and lower noise levels. To reduce noiselevels further and <strong>com</strong>ply with inner city residential noise regulations, all outdoor units include Night Set-backmode. This function works by lowering the fan speed and <strong>com</strong>pressor frequency proportionally with reduction indemand.The Strength of <strong>City</strong> <strong>Multi</strong>New inverter drivenoutdoor fan motorThe <strong>com</strong>pressor <strong>com</strong>partment issealed by metal panels to attaina low noise level in all directions.Increased Pipe LengthsTotal system pipe lengths of up to 1000m(3280ft) andfurthest pipe lengths of 165m(541ft) make the <strong>City</strong><strong>Multi</strong> Y series system one of the most flexible VRFsystems in the marketTop-bottom differential50m[164ft]Outdoor unitFurthest piping length190m[623ft] (equivalent length)(actual length 165m[541ft])LowNoiseLow NoiseNewly designed refrigerantcircuit (low pressure loss)Highly efficient R410AScroll <strong>com</strong>pressorIndoor unitbetween indoor unitstop-bottom differential15m[49ft]Y SeriesPage 13 Page 14


Heating Operation RangeAt low ambient temperature the guaranteed operating range is now expanded to –20˚C[–4˚F] in heating and43˚C[109˚F] in cooling.-20˚C[-4˚F]Outdoor temperature(wet bulb temperature)In cooling modeIn heating mode15.5˚C[60˚F]Operating range in cooling is from an outdoortemperature of -5˚C[23˚F], while that in heating hasexpanded to an outdoor temperature of -20˚C[-4˚F]-5˚C[23˚F]Outdoor temperature(dry bulb temperature)43˚C[109˚F]-20˚C[-4˚F] -10˚C[14˚F] 0˚C[32˚F] 10˚C[50˚F] 20˚C[68˚F] 30˚C[86˚F] 40˚C[104˚F]Blue Fin TreatmentThe anti-corrosion Blue Fin treatment of the heat exchanger is especiallyeffective in urban environments where the traffic pollutions can damage thealuminum fins reducing the capacity and life expectancy of the unit. All <strong>City</strong><strong>Multi</strong> R410A outdoor units have been treated with Blue Fin.The Strengthof New <strong>City</strong> <strong>Multi</strong>Easy MaintenanceEven when one of the indoor units in the system isunder maintenance, the other indoor unit can beoperated.R410A Pipe SizingConventionalmm(in.)Under maintenanceIn operationAs R410A has a higher specific heat capacity than R22,the pipework is smaller. This means the pipe itself ischeaper, easier to install and therefore less riser space isrequired within the building.Gaspipingf28.58(f1-1/8)Liquidpipingf12.7(f1/2)Gaspipingf22.2(f7/8)Liquidpipingf9.52(f3/8)Based on 10HP modelCooling Operation Set Temperature of 14˚C[57˚F]Gyms, laboratories etc often require the ability to coollower than the standard <strong>com</strong>fort cooling setpoint. Byselecting a dip switch on the unit, a cooling operation settemperature of 14˚C[57˚F] DB is possible on PFFY-VLEM/VLRM and PEFY series. The indoor unit fan will befixed at high speed during this operation. (except PUMY)* CITY MULTI is an air conditioning system designed for rooms andareas where people work or relax, not for machine rooms.* Not applicable to all situations.* Be sure to turn off the power to the indoor unit when repairing or servicing the unit.Automatic System CheckEnsuring simple and easy maintenance, automatic system tests are possible for wiring,sensors and refrigerant amount.Page 15 Page 16


The importance of controlRemote ControllerIndividual Remote ControllerCentralized Remote ControllerThe need for control is paramount in orderto optimise the performance of anyair conditioning system and minimizeits running costs. Mitsubishi Electric offersa wide range of control options designedto meet such needs.Operating an air conditioning system withoutthe right control can prove costly. It's thereforeimportant to ensure that every system is correctlyspecified to the degree of control it requires.Mitsubishi Electric have a wide range ofcontrols available 'off-the-shelf' and individualcontrol systems can be specifically designed tomatch.Good controls will benefit any application,large or small. Air conditioning products needto react to a variety of factors: different room sizes,usage and staff levels; changes in the climate;electronic equipment and lighting ...thelist goes on. So whatever the application, optimumcontrol of air conditioning systems is essentialand will result in a constant, <strong>com</strong>fortableenvironment, which in turn is both energyand cost efficient.A degree of differenceWhen an air conditioning system is not properlycontrolled, it will not run as efficiently as itshould. For every degree that the system deviatesfrom the required temperature, energycosts can rise by up to 5%. Specify one of themany control options from Mitsubishi Electricto ensure air conditioning works as intended,whilst giving the optimum amount of control.The simpler, the betterWith the array of <strong>com</strong>prehensive control systemsavailable from Mitsubishi Electric, it be<strong>com</strong>essimple to design and install air conditioningsystems. From a simple hand-heldcontroller to a G50 system - you are in control.Remote ControllerPage 17 Page 18


System ControllerMITSUBISHI ELECTRIC's Air-conditioner Network System (MELANS) leads air conditioner management a PCbrowser and Network era.M-NETMELANSMALANS has a large line-up, including local remote controllers, timers, grouping controllers, central controllers,and centralized integrated software, PLC and its software, as well as BMS interface hardware and software etc.The <strong>com</strong>bination of the MELANS products can fulfill the requirements of small-scaled control system, middlescaledcontrol system up to 2000 indoor units, and/or large-scaled opening system affiliated to a BMS system.Moreover, with central controller G-50A/GB-50A, PC browser and long distance remote control (monitoring andoperating) via net-work is possible and easy.I ndividual Remote ControllerAll of the local remote controllers feature liquidcrystal and LED displays and easy to operate.RemoteControllerPAR-21MAAPAR-F27MEAOUTDOOR UNITY :PUHYInterfaceLMAP02SimpleRemoteControllerPAC-SE51CRAPAC-YT51CRBWirelessRemoteControllerLON WORKS TM transmission linePAR-FL32MA PAR-FA32MAINDOOR UNITPLFY-VBMPLFY-VLMDPMFY-VBMPEFY-VMRPEFY-VMSPDFY-VMPEFY-VMLBACnet TM interface softwarePAC-YG31CDABACnet TM transmission lineMITSUBISHI ELECTRIC's CITYMULTI canbe easily connected to the buildingmanagement system through BACnet TM .EthernetC entralized Remote ControllerSystemRemoteControllerPAC-SF44SRAPEFY-VMHPCFY-VGMPKFY-VBM / VGM / VFMPFFY-VLEMPFFY-VLRMFresh Air Intake typeScheduleTimerPAC-YT34STAG-50AON/OFFRemoteControllerPAC-YT40ANRAGroupRemoteControllerPAC-SC30GRAGB-50AA ir-ConditioningControl SystemThis is a specialized air conditioningmanagement system, inwhich up to 2000 indoor unitscan be centrally controlled.Integrated centralizedcontrol software TG-2000AIntegrated Communications Controlwith Mitsubishi's Unique Transmission Network (M-NET)OperationMonitoringSchedulingRecordingOthersControl andmanagementOperationMonitoringStart / StopOperation modeTemperature settingPermit / Prohibit directionFan speedAir flow directionON/OFFError flashingError contentFilter signOperating hourOperation modeSet temperatureIndoor temperature (intake)Permit / ProhibitFan speedAir flow directionWeeklyAnnual (Designated day setting)One dayTimes of stops / Starts per dayTimes of stops / Starts per weekAuto off timerMinimum setting unit (minutes)Error historyDaily / Monthly reportsElectricity chargesSet temperature range limitAuto lockVentilation (group / interlocked)Group settingBlock settingRevision of electricity chargesStart / StopFan speedVentilation modeStatusFan speedVentilation modeVentilation(group / interlocked)Ventilation(group / interlocked)ModelNo. of units controllable(Groups (G) / units)Local remote controllerSystem controllerRemote controllerSimple Wireless SystemON/OFF Groupremote remote remote Schedule remote remotecontroller controller controller timer controller controllerCentralized controllerPAR-21MAA PAR-F27MEA PAC-SE/YT51CRA(B) PAR-FL32MAPAR-FA32MAPAC-SF44SRA PAC-YT34STA PAC-YT40ANRA PAC-SC30GRA G-50AGB-50A1G/16units 1G/16units 1G/16units 1G/16units 50/50 50G/50U 16/50 8G/16units50G/50units 50G/50unitsG-50A browser GB-50A browser✕✕✕8561✕✕✕✕ /✕✕*5*5*5*1✕✕✕✕1/1✕10 *5✕✕✕✕ /✕✕✕✕ /✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕ /✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕1/1✕✕10✕✕✕✕✕✕✕✕✕✕✕✕✕✕: Each group / Batched : Each group : Block (<strong>City</strong> <strong>Multi</strong> indoor unit only) : Batched handling (for maintenance): Batched only ✕ : Not available – : Not used : G-50A license registration possible.* 1: For group operation, cross-over wring is required between indoor unit. * 2: Installation possible at Initial setting tool.* 3: Interlock setting from local remote controller. * 4: From schedule setting * 5: When PAC-YT32PTA is connected.✕✕✕✕✕✕✕✕✕✕✕✕✕✕/// ✕/// ✕✕✕✕✕✕✕✕✕✕✕✕16112✕5✕✕✕✕✕✕✕/✕✕✕✕✕*4*4*4✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕/ ✕✕✕*3/✕✕✕✕✕✕✕✕/ *5✕✕✕/48 *5✕✕✕3/3✕/336 * 521/21✕✕/30 *5✕✕✕✕✕ /✕✕// ✕/// ✕✕10✕✕✕✕✕✕/// ✕/// ✕✕1284✕1✕✕*2✕/✕/// ✕//*2*2*2/ ✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕✕/✕✕/✕✕✕1284✕1✕✕*2✕*2/*2✕/// ✕//*2/ ✕TG-2000A2000G/2000units1284✕1✕//// ✕/// ✕Remote ControllerRemote ControllerPage 19 Page 20


TIMESUN˚FAUTO OFFControl SystemsIndividual Control SystemsWired MA remote controller PAR-21MAAExample of system configurationM-NETNon-polarized2-wireMA remote controllerNon-polarized2-wireMA remote controllerVarious control systems can be offered with indoor unit remote controller.• Dot matrix liquid crystal screen displays <strong>com</strong>plete operatingstatus.• Digital display lets you set temperature in 1˚C/˚F increments.• Weekly Timer: up to 8 ON/OFF/Temperature Settings can bemade per day. The time can be set in 1-minute increments.The setting is kept in nonvolatile memory. No need to worryabout re-setting at power failure.• Equipped with a thermostat sensor in the remote controllerthat makes possible more <strong>com</strong>fortable room temperature control.• Ability to limit the set temperature (upper and lower temperaturecan be set.)• Ability to restrict setting changes (either all changes or all exceptON/OFF)• Constantly monitors for malfunctions in the system, and isequipped with a “self-diagnosis function” that lets you know byerror code immediately when a malfunction occurs.• Dimensions: 120(W) x100(H) x 19(D) mmNew display-Larger,easier-to-see charactersVarious information is displayed and conveyed clearly, enabling more accurate operation of the air conditioner.Dot Liquid Crystal Display (LCD)The dot liquid crystal display enables quick understandingof the operation state.<strong>Multi</strong>-language DisplayIn addition to English, contents can be displayed in sevenother languages.This function makes the remote controller very useful in facilitieswhere foreigners are present.● Display example [Operation mode]Dot liquid crystal display● Display example [Cool mode][English][Itarian][German][Chinese]˚FTEMP.[Spanish][French]WEEKLYSIMPLEON/OFF[Russian][Japanese]Outdoor unitGroup controlA remote controller can control up to 16indoor units at the same time.(Automatic address setting)<strong>Multi</strong> Language Display Example[Dot display table]Selecting language English Germany Spanish Russian Italy Chinese French JapaneseWaiting for start-upOperation modeCoolCooling/Heatingmode switch controlCooling/Heating mode ofthe outdoor unit can beswitched with the remotecontroller for indoor unit.RemotecontrollerRemotecontrollerDryHeatAutoAuto(Cool)Auto(Heat)FanRemotecontrollerRemotecontrollerVentilationStand by(Hot adjust)DefrostLossnayNot use buttonCheck (Error)Two-remote-controllercontrolBy connecting with two remotecontrollers, an outdoorunit can be controlled freelyeither from the one in theroom or from the one in thecontrol room. (Last settingoverride)Group control is possible byusing two remote controllers.RemotecontrollerRemotecontrollerRemotecontrollerRemote controlRemote controller wiring can be extendedup to 200m, which makes it possible for theindoor unit remote controllers to be installedat one place without being separated.RemotecontrollerInterlocking controlHeat recovery ventilator (Lossnay)can be operated and controlled withindoor unit remote controller.Test runSelf checkUnit function selectionSetting of ventilationRemote ControllerRemote ControllerPage 21 Page 22


UPControl SystemsIndividual Control SystemsWired ME remote controller PAR-F27MEAWireless remote controller PAR-FL32MA / PAR-FA32MAExample of system configuration• This remote control requires non-polar wiring to only oneindoor unit.• Group operation over multiple outdoor units is possible.Grouping can be changed without re-wiring, which makesdividing rooms for tenant easier.• Timer operation*Daily timer operation of one ON/OFF setting everyday*Auto-off timer : 0:30, 1:00, 1:30, 2:00...4:00*The setting is kept in nonvolatile memory.• Function lockAll functions or all functions except ON / OFF can be selected.• Set temperature range limit• Interlock setting and operation of LOSSNAY• Dimensions:130(W) x 120(H) x 19(D) mmPAR-FL32MAPAR-FA32MA• No need to configure addresses for group operation.• Lit LED keeps you informed of operation - blinking evengives you the error code via the number of blinks.• Can be used with the MA remote controller.*When used in group configurations, wiring between indoorunits is required.*Combining ME remote controller and/or LOSSNAY remotecontrollerin a group is not possible.• LCD temperature setting and display in 1˚C /1˚F unit.• Dimensions:58(W) x 159(H) x 19(D) mmExample of system configurationME R/CSimple remote controller PAC-YT51CRB(MA)PAC-SE51CRAME R/C• Control: START/STOP, room temperature, fan speed, andoperation mode• The only wiring required is cross-over wiring based ontwo-wire signal lines.• Room temperature sensors are built-in.• LCD temperature setting and display in 1˚C /1˚F unit.• Set temperature range limit• Can operate all types of indoor units*Since this controller has limited functions, it should always beused in conjunction with standard controller or centralizedcontroller.• Dimensions:70(W) x 120(H) x 41(D) mmSignalreceivingunitWirelessremotecontrollerNon-polarized2-wireSignalreceivingunitWirelessremotecontrollerNonpolarized2-wireSignalreceivingunitWirelessremotecontrollerNonpolarized2-wireExample of system configurationNote) PAC-SE51CRA, easy group changing type, is available.Refer to the specification sheet for details.Central controllerPower supply unitSimpleMA R/CSimpleMA R/CRemote ControllerRemote ControllerPage 23 Page 24


UPUPCentralizedRemote ControllerOne system controller can control up to fifty indoor units from one location. The PAC-SF44SRA also hashardwired connection available (On/Off input, fire alarm input, run output, fault output).System remote controller PAC-SF44SRAMitsubishi Electric controllers are <strong>com</strong>plimented by a weekly programmable timer, being able to control upto fifty indoor units. The PAC-YT34STA also has hardwired connection available (On/Off input, fire alarminput, run output, fault output).Schedule timer PAC-YT34STASystem ControllerProgrammable Timer• The group setting is kept in nonvolatile memory.No need to worry about re-setting at power failure.• No individual AC power supply is needed.The power can be supplied from one outdoor unit(R410A) or Power supply unit.FUNCTIONUNITSON/OFFMODE SELECTIONTEMPERATURE SETTINGFAN SPEED SETTINGSAIR FLOW DIRECTION SETTINGPERMIT/PROHIBIT FUNCTIONERROR INDICATIONVENTILATION INTERLOCKEXTERNAL INPUTEXTERNAL OUTPUT• Dimensions:130(W) x 120(H) x 19(D) mmDESCRIPTIONPAC-SF44SRAMax No.Units50 units/50 groupOperation DisplaysRun and stop operationSwitches between Cool/Dry/Auto/Fan/Heat.Operation Mode will vary depending on theindoor unit. Auto mode is available with onlyR2 and WR2 systemsSets the groups temperature control.Cool/Dry:19-30˚CHeat:17-28˚CAuto:19-28˚C4 speed – Hi-Mid2-Mid1-Low, Auto3 speed – Hi-Mid-Low, Auto2 speed – Hi-LowAir flow angles: 4-angle or 5-angle, Swing, Auto,Louver ON/OFFRun/Stop,Temperature Setting,Mode Selectionand Filter Reset functions can be prohibited.Displays a 4 digit code and the affectedunit addressAllows the group to be interlocked with a heatrecovery Lossnay unitOn/Off/Fire AlarmOn/Off/Faults• The schedule group setting is kept in nonvolatilememory. No need to worry about re-setting atpower failure.• No individual AC power supply is needed.The power can be supplied from one outdoor unit(R410A) or Power supply unit.FUNCTIONUNITSON/OFFSCHEDULEFUNCTIONContentNumberUnitCURRENT TIMEERROR INDICATIONEXTERNAL INPUTEXTERNAL OUTPUT• Dimensions:130(W) x 120(H) x 19(D) mmDESCRIPTIONPAC-YT34STAMax No.Units50 units/50 groupOperation DisplaysRun and stop operationOn/OffMode:Cool/Heat/AutoSet temperature:19˚C to 28˚COperation Prohibit: On/Off, Mode, Set temperatureWeekly timer for each group9 setting patterns + no setting16 operations per day5 minutesSet the timeDisplays a 4 digit code and the affectedunit addressOn/Off/Fire AlarmOn/Off/FaultsSystem exampleSystem exampleSystemremotecontrollerPower supplyunitPAR-21MAAPAR-21MAASystemremotecontrollerPower supplyunitPAR-F27MEALOSSNAYSchedule timerLOSSNAYLOSSNAYLOSSNAYPZ-52SFPZ-52SFPAR-21MAASimplePAC-SE51CRAR / C : Remote ComtrollerR / C : Remote ComtrollerRemote ControllerRemote ControllerPage 25 Page 26


UPCentralizedRemote ControllerJust press a switch to start. All of the units can be On/Off by pressing the main switch, and each unit inthe group can be On/Off with individual switch. The PAC-YT40ANRA also has hardwired connectionavailable (On/Off input, fire alarm input, run output, fault output).Up to 8 groups can be operated (maximum of 16 units). Just by pressing PAC-SC30GRA switches, groups canbe On/Off as a batch.Suitable for small office and residential project.ON/OFF remote controller PAC-YT40ANRAGroup remote controller PAC-SC30GRAFUNCTIONDESCRIPTIONPAC-YT40ANRAFUNCTIONDESCRIPTIONPAC-SC30GRAUNITSMax No.Units50 units/16 groupUNITSMax No.Units16 units/ 8 groupOPERATIONS DISPLAYOPERATIONS DISPLAY• The group setting is kept in nonvolatile memory.No need to worry about re-setting at powerfailure.• No individual AC power supply is needed.The power can be supplied from one outdoorunit (R410A) or Power supply unit.ON/OFFERROR INDICATIONVENTILATION OPERATION(INDEPENDENT)VENTILATION OPERATION(INTERLOCKED)EXTERNAL INPUTEXTERNAL OUTPUT• Dimensions:130(W) x 120(H) x 19(D) mmRun and stop operationLED flashes during failure.(The error code can be confirmed by removingthe cover.)Group operation of only LOSSNAY units possible.*Only ON/OFF of group.The LOSSNAY will run in interlock with theoperation of indoor unit.*The fan rate and mode cannot be changed.The LED will turn ON only during operation after interlocking.On/Off/Fire AlarmOn/Off/Faults• The group setting is kept in nonvolatile memory.No need to worry about re-setting at powerfailure.• No individual AC power supply is needed.The power can be supplied from one outdoorunit (R410A) or Power supply unit.System exampleON/OFFMODESELECTIONTEMPERATURE SETTINGFAN SPEED SETTINGSAIR FLOW DIRECTION SETTINGPERMIT/PROHIBIT FUNCTIONINDOOR RETURN AIR TEMPERATUREERROR INDICATIONVENTILATION INTERLOCK• Dimensions:130(W) x 120(H) x 19(D) mmRun and stop operationSwitches betweenCool/Dry/Auto/Fan/Heat.Operation Mode will vary depending on theindoor unit. Auto mode is available with onlyR2 and WR2 systemsSets the groups temperature control.Cool/Dry:19-30˚CHeat:17-28˚CAuto:19-28˚C4 speed – Hi-Mid2-Mid1-Low, Auto3 speed – Hi-Mid-Low, Auto2 speed – Hi-LowAir flow angles: 4-angle or 5-angle, Swing, Auto,Louver ON/OFFRun/Stop,Temperature Setting,Mode Selectionand Filter Reset functions can be prohibitedvia main system controllerMeasures the intake temperature of themaster unit within the groupDisplays a 4 digit code and the affectedunit addressAllows the group to be interlocked with a heatrecovery Lossnay unitConnect to the centralized transmission lineSystem exampleGroup remotecontrollerLOSSNAYPower supplyunitON/OFFremotecontrollerPAR-F27MEAPZ-52SFR/C:Remote ControllerConnect to the indoor/outdoor transmission linePAR-21MAAPAR-21MAAPAR-21MAAPAC-YT51CRBR/C:Remote ControllerGroup remotecontrollerPAR-21MAAPAR-21MAARemote ControllerRemote ControllerPage 27 Page 28


UPUPPOWER SUPPLY UNITMODEL PAC-SC50KUAPOWER RATINGWEIGHT2.11kgSERIAL No.MITSUBISHI ELECTRIC CORPORATIONPOWER SUPPLY UNITMODEL PAC-SC50KUAPOWER RATINGWEIGHT2.11kgSERIAL No.MITSUBISHI ELECTRIC CORPORATIONCentralizedRemote ControllerCentral controller G-50A/GB-50AUp to 50 indoor units can be monitored and operated!Furthermore, it has enabled the Monitoring and OperationVia a Web Browser on a Personal Computerconnected by using a LAN or telephone line!G-50A (with display)First in the industryWith Web ServerFunctions!GB-50A• Simple and FlexibleThis new generation controller is suitable for small to largesystems with simple to <strong>com</strong>plex functions available.• Web BrowserEnables monitoring and operation of air conditioning units usinga PC with Microsoft ® Internet Explorer.• Remote AccessAllows users to remotely monitor and operate the air conditioningunits using a PC connected to a telephone line.• Auto AlarmIn case of any malfunction, necessary information will be sentto a mobile phone and/or personal <strong>com</strong>puter by e-mail.• Easy to UpgradeVarious new functions will be introduced gradually and caneasily be down loaded into any existing G-50A/GB-50A.Example: Personal web by Macintosh PCNight setbackAuto Cool/Heat changeover• Powerful <strong>com</strong>bination with PLC MELSEC-Q series(Programmable logic controller from Mitsubishi Electric)Example of display icons (air conditioner icons)OperationStopOccurrence ofabnormalityOperation/Occurrence of a filter signIn timer operationLossnay onUnder energy-savingcontrol<strong>Multi</strong> language display with easy-understanding icons onweb browser.(English, French, German, Italian, Spanish, Russian,Chinese)System StructureRemote monitoring via aWeb browserPublic telephonelineProviderProviderRouterWeb browserEthernet* Microsoft is a trademark or trademark of Microsoft corporation.G50 Centralized ControllerFUNCTIONMAX No.OF INDOOR UNITSON/OFFMODE SELECTIONTEMPERATURE SETTINGFAN SPEED SETTINGAIR FLOW DIRECTION SETTINGTIMER OPERATIONPERMIT/PROHIBIT FUNCTIONINDOOR RETURN AIRTEMPERATUREERROR INDICATIONTEST RUN FUNCTIONVENTILATION INTERLOCKWEB SETPOINT/LIMITWEB AUTO/CHANGEOVERWEB INITIAL/SETTINGWEB LOGINEXTERNAL INPUT/OUTPUTPOWER SUPPLY UNITG50 Software OptionsG50 -Web Monitor Control and Monitor the G50 via Internet ExplorerG50 - EmailEnable E-mail activation on fault conditionsG50 - Schedule Weekly / Annual SchedulingG50 - ChargeEnergy ChargeG-50AGB-50APower supply unitPAC-SC50KUAPower supply unitPAC-SC50KUAG50 - Saving EnergyG50 - Peak CutG50 - Personal WebG50 - BacNetM-NET<strong>City</strong> <strong>Multi</strong>M-NET<strong>City</strong> <strong>Multi</strong>DESCRIPTIONUp to 50 indoor units can be connectedRun and Stop operationSwitches between Cool/Dry/Auto/Fan/Heat.Operation Mode will vary depending on the indoor unit.Sets the groups temperature control.Cool/Dry:19-30˚C,Heat:17-28˚C,Auto:19-28˚C4 speed – Hi-Mid2-Mid1-Low/Auto, 3 speed – Hi-Mid-Low/Auto, 2 speed – Hi-LowAir flow angles: 4-angle or 5-angle, Swing, Auto, Louver ON/OFFMaximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocatedIndividual prohibit operations for each remote controller function (Run/Stop, Temperature Setting,Mode Selectionand Filter Reset) can be activatedDisplays the measured intake temperature from each groupDisplays a 4 digit code and the affected unit address.An error log is held showing the last 64 date stamped alarmsAllows each unit within the group to operate in test modeAllows the group to be interlocked with a heat recovery Lossnay unitReduce the setpoint band of each individual unit (exp.23˚C to 25˚C)Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirementsCommission the G50 from the web pagesTwo types of login available (Administrator & Guest).Administrator able to allow specific function access to guestHardwired connections are available for : Inputs: Level Signal-Batch Start/Stop,Batch Emergency StopPulse Signal-Batch Start/Stop,Enable/Disable Local R/COutputs: Start/Stop Status,Error/Normal StatusPAC-SC50KUAEnergy Saving CapabilityPeak Cut ControlVirtual Remote ControllersBacnet interfaceRemote ControllerRemote ControllerPage 29 Page 30


UPPOWER SUPPLY UNITMODEL PAC-SC50KUAPOWER RATINGWEIGHT2.11kgSERIAL No.MITSUBISHI ELECTRIC CORPORATIONCentralizedRemote ControllerIntegrated centralized control software TG-2000AExample of Basic System Configuration.ChargelicenseWebmonitorlicenseSchedulelicenseInputUninterruptivepower supply (UPS)Integratedcentralized controlsoftware installationG-50APower supply unitPAC-SC50KUAM-NETOutdoor unitwatt-hour meterRS-232CTG-2000ARS-485ConverterIndoor unitwatt-hour meterIndoor unitwatt-hour meterMain features of TG-2000A12345678Up to 2000 indoor units (40 G-50A/GB-50A units) can be operated and monitored simultaneously.The air-conditioner layout can be displayed on the screen, making control and operation easier.The annual and weekly schedules can be set. Two schedules, such as the summer master and winter master, can besaved in the weekly schedule.<strong>Multi</strong>ple air-conditioning charges can be calculated. The power apportionment percentage data and apportioned powerrate can be calculated for each indoor unit using the power apportionment function, and can be output as a CSV formatfile. * Power apportionment charging is not possible with the old model, A control or K control.Charging without WHM : The user manually inputs the power rate to calculate the air-conditioningcharges. (Using a tool)RS-485 WHM charging : The RS-485 WHM value is automatically tabulated to calculate theair-conditioning charges.PLC + pulse WHM charging : The pulse output WHM value is automatically tabulated by the PLC to calculatethe air-conditioning charges.Energy saving operation is possible using the "ON/OFF", "set temperature change", "fan operation changeover" and"performance save operation (60% to 90%)" functions.Energy saving operation matching the amount of power in use is possible by using the PLC's electric amount countsoftware.Night set-back operation is possible with schedule settings. *1*4General equipment can be operated and monitored. *2General equipment can be schedule-controlled when using PAC-YG21CDA with PLC.For details of PLC refer to Installation Manual of PAC-YG21CDA. *3*1: Compatible with TG-2000A Ver. 4.10 and higher, G-50A Ver. 2.51 and higher.*2: Compatible with TG-2000A Ver. 4.30 and higher, G-50A Ver. 2.51 and higher.*3: Compatible with TG-2000A Ver. 4.60 and higher, G-50A Ver. 2.70 and higher.*4: With Night Set-Back function,the CITY MULTI system can run at heating mode with target temperature setto 12˚C/54˚Funder schedule control. This function can protect the room from dropping down to extremelylow temperature at mid-night.Compatible with TG-2000A Ver. 4.10 and higher* The electric amount count software or separatelyprocured parts must be used with the designated PLC.power sourceIndoor unitwatt-hour meterOutdoor unitwatt-hour meterIndoor unitwatt-hour meterThe TG-2000A enables the following functions usingthe G-50A/GB-50A option (license).* Operation/monitor* Annual/weekly schedule* Calculating electricity* Energy saving *1* Peak cut *1*1: Compatible with TG-2000A Ver. 4.10 and higher,G-50A Ver. 2.51 or later.PLC (with electric amount countsoftware)Uninterruptiblepower supply (UPS)TG-2000AIntegrated centralized controlsoftware installationRemote ControllerRemote ControllerPage 31 Page 32


UPLONWORKS (LMAP02)CITY MULTI can easily <strong>com</strong>bine into a Building Management System (BMS) via the LonWorks TM and M-NET adapter LMAP02.LonWorks TM is an opened transmission protocol widely used at BMS, and related equipment control.CITY MULTI is therefore <strong>com</strong>patible with large-scaled BMS management via LonWorks TM .BACnet TM interface(PAC-YG31CDA)MITSUBISHI ELECTRIC's CITYMULTI can be easily connected to the building management system through BACnet TM . BACnet TM is theappropriate transmission method and used in many of the backbone networks and also it is easy to <strong>com</strong>bine with other equipmentcorresponding to BACnet TM .One LM ADAPTER unit can connect up to 50 Groups/50 indoor units.Using a single LONWORKS adapter (LM ADAPTER), you can connect up to a maximum of 50 indoor units.One BACnet TM interface software manages up to 500 Groups/500 Indoor units. (10 G-50A/GB-50A units).LMAPLMAP 02Protocol converterbetween LON WORKSand M-NETLON WORKSLMAPM-NETExample of Basic System Configuration.CentralmonitorBMSCITY MULTI SystemTMBACnetExample of System ConfigurationSystem design made simple through integration ofvarious devices into a total control configuration.Outdoor unitCITY MULTIOutdoor unitLANG-50AM-NETWHMWHMLON WORKS(78kbps)LMAPM-NETTMBACnet interface softwarePAC-YG31CDAM-NETPAC-SC50KUAPower supply unitIndoor unitsMax. 50 indoor unitsIndoor unitsIndoor unitsIndoor unitsIndoor unitsG-50ACentercontrol deviceLightingSecurityRemotecontrollerRemotecontrollerRemotecontrollerRemotecontrollerRemotecontrollerWebBrowser(Optional)TG-2000A(Optional)LON WORKSThe building management system is connected to the CITY MULTI air conditioning system using LON WORKS , which is widely used onfield networks, allowing for an open network and savings in construction to face.LON, LON WORKS and the Echelon logo are trademarks of Echelon Corporation registered in the UnitedStates and other countries.®LONWORKS INTERFACEFUNCTIONControlON/OFFMODE OPERATIONSETPOINT ADJUSTMENTFAN SPEED CONTROLPERMIT / PROHIBITEMERGENCY STOPMonitoringON/OFFMODESETPOINTFAN SPEEDPERMIT / PROHIBITALARM STATEROOM TEMPERATURETHERMO ON/OFFCONTENTRun/StopCooling/Drying/Heating/Auto/FanCooling 19-30˚C,Heating 17-28˚C,Auto 19-28˚CLo-Mi1-Mi2-HiOn/Off,Mode,Setpoint-Run/StopCooling/Drying/Heating/Auto/FanCooling 19-30˚C,Heating 17-28˚C,Auto 19-28˚CLo-Mi1-Mi2-HiOn/Off,Mode,Setpoint--10˚C~50˚COn/Off®BACnet INTERFACEFUNCTIONControlON/OFFMODE OPERATIONSETPOINT ADJUSTMENTFAN SPEED CONTROLPERMIT / PROHIBITAIRFLOW DIRECTIONFILTER DIRTY RESETMonitoringON/OFFMODESETPOINTFAN SPEEDPERMIT / PROHIBITAIRFLOW DIRECTIONFAULT CODEFILTER SIGNROOM TEMPERATURECOMMUNICATION STATUSCONTENTRun/StopCool/Dry/Heat/Auto/FanCooling 19-30˚C,Heating 17-28˚C,Auto 19-28˚CLo-Mi1-Mi2-HiOn/Off,Mode,Setpoint,Filter sign reset, Air flow directionHorizontal - 60˚-80˚-100˚ swingNormal/Reset,Emergency stopRun/StopCool/Dry/Heat/FanCooling 19-30˚C,Heating 17-28˚C,Auto 19-28˚CLo-Mi1-Mi2-HiOn/Off,Mode,Setpoint,Filter sign resetHorizontal - 60˚-80˚-100˚ swing2 Character code - Indicates all unit alarms---Remote ControllerRemote ControllerPage 33 Page 34


Wide selection of indoor unitsCeiling cassette (4way air flow)NewPage37 - Page38PLFY-P VBM-EPLFY-VCM-EFresh Air IntakePage53 - Page54PEFY-P VMH-E-FModelP20 P25 P32 P40 P50Capacity2.2kW 2.8kW 3.6kW 4.5kW 5.6kWModelCapacityP63 P80 P100 P1257.1kW 9.0kW 11.2kW 14.0kWModelCapacityP80 P140 P200 P2509.0kW 16.0kW 22.4kW 28.0kWCeiling cassette (2way air flow)Page39 - Page40Ceiling suspendedPage55 - Page56PLFY-P VLMD-EPCFY-P VGM-EModelCapacityP20 P25 P32 P40 P502.2kW 2.8kW 3.6kW 4.5kW 5.6kWI ndoor unitModel P63 P71 P80 P100 P125Capacity 7.1kW 8.0kW 9.0kW 11.2kW 14.0kWCeiling cassette (1way air flow)Page41 - Page42Model P40 P63 P100 P125Capacity 4.5kW 7.1kW 11.2kW 14.0kWWall mountedPage57 - Page58NewPKFY-P VBM-EPMFY-P VBM-ECeiling cassette type 4-way airflowPKFY-P VFM-ECeiling cassette type 2-way airflowPKFY-P VGM-ECeiling cassette type 1-way airflowCeiling concealed typeCeiling suspended typeWall mounted typeFloor standing typeOA Processing UnitsModel P20 P25 P32 P40Capacity 2.2kW 2.8kW 3.6kW 4.5kWCeiling concealedNewPEFY-P VMR-E-L/RPEFY-P VML-ENewPage43 - Page52PDFY-P VM-EPEFY-P VMS-EPEFY-P VMH-EModel P20 P25 P32 P40 P50 P63 P71Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 8.0kWModel P80 P100 P125 P140 P200 P250Capacity 9.0kW 11.2kW 14.0kW 16.0kW 22.4kW 28.0kWModel P20 P25 P32 P40 P50 P63 P100Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 11.2kWFloor standingPFFY-P VLRM-EPage59 - Page62NewPFFY-P VKM-EPFFY-P VLEM-EModel P20 P25 P32 P40 P50 P63Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kWIndoor unitPage 35 Page 36


The Ventilation System for Enhanced Air Quality - LossnayCombine with Lossnay Ventilation System Enhanced Air Quality.Unified Control System Allows Greater Design Freedom.LOSSNAY Technology• Two paths ventilationLOSSNAY simultaneously intakes Fresh Air and exhausts Dirty Air.• Total energy recoverLOSSNAY returns BOTH sensible heat and latent heat.A. Two paths ventilationB. Total Energy transfer0ûC (32ûF)Fresh cool air(outdoor)5.2ûC (41.3ûF)Stale hot air (exhaust)EAStale air exhaust(dirty indoor air)OutdoorsIndoorsSAFresh air exhaust(fresh heating/cooling air)Partition plateSpacer plateOAFresh air induction(fresh air)RAStale air induction(dirty heating/cooling air)20ûC (68ûF)Stale warm air (indoor air)• Hyper Performance [HYPER CORE]Mitsubishi developed “ HYPER CORE “ of World No.1Sensible heatLatent heat14.8ûC (58.6ûF)Fresh warm air (indoor supply air)No dirty air returnLOSSNAY recovers energy but does NOT return dirtyair to indoor by Non porous paper.High PerformanceMitsubishi has World No.1 Energy exchange efficiency.LGH-15RX4 [150m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-80RX4 [800m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-25RX4 [250m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-100RX4 [1000m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-35RX4 [350m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-150RX4 [1500m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-50RX4 [500m 3 /h Single phase 220-240V 50Hz/60Hz]LGH-200RX4 [2000m 3 /h Single phase 220-240V 50Hz/60Hz]Heat-Exchange Efficiency Obtainable Only with Lossnay.25µmWater moleculeGas (CO2) moleculeExhaust airflowEnthalpy exchange efficiency (for cooling)70%60%64.56562.5 62.56865.564.5 64.561.564.5 64.5 64.5 64.5Conventional modelsUPby 3 to 4pointRX46867 67 67The secret to the unmatched <strong>com</strong>fort provided by Lossnay core is the cross-flow, plate-fin structure off the heatexchangeunit. A diaphragm made of a specially processed paper fully separates inducted and exhausted air supplies,ensuring that only fresh air is introduced to the indoor environment.The superior heat-transfer and moisture permeability of the special paper assure highly effective total heat exchange(temperature and humidity) when inducted and exhausted air supplies cross in the Lossnay core.Supply airflowNon-porous ultra-thin filmmaterial: 25µm15RX425RX4 35RX4 50RX4 65RX4 80RX4 100RX4 150RX4 200RX4Indoor unitLOSSNAYPage 63 Page 64


RX4 SERIESWhy LOSSNAY is necessary.• Without ventilation...Lack of Ventilation makes people sick by dirty indoor air including CO2, Dust, Bacteria.• If just opening windows...Opening windows eliminates dirty air BUT wastes much air-con energy.• So we re<strong>com</strong>mend LOSSNAYLOSSNAY is simultaneous pursuit of Ventilation and Energy Saving.LOSSNAY features<strong>Multi</strong> Ventilation Mode to control air volume balanceNormal office,etc.Smaller offices or tenant buildings,etc.Smoking areas,etc.VentilationEnergy SaveMany people in an office Extractor fan working place Priority air exhaustPower air supply/exhaust Power air supply Power air exhaustAll LGH models feature the "<strong>Multi</strong>-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamicallyto suit the usage environment and location. Modes can be selected easily by setting the connectors on the circuitboard.• This is LOSSNAY !ADVANTAGESClean air supply, dirty air exhaust by Two air paths (OA SA and RA EA)Energy recovery by LOSSNAY CoreFree cooling by bypass damperMULTI VENTILATION MODE for multi ventilation request (Power supply, Power supply/exhaust, Power exhaust)Ventilation ModePower air supply/exhaust modePower air supply modePower air exhaust modeEnergy-saving ventilation modeSupplyAirflowHighHighLowLowExhaustAirflowHighLowHighLow* "High" can be further set to "Extra high" using the dip switch.UNIT STRUCTUREEnergy Recovery ImageEA (exhaust air)LOSSNAY CoreEasy InstallationFlexible duct work is available.Standard installationInstallationOA (outside air)Bypass damperAir conditionerA space is necessaryto prevent the influxof rainwater.Can be installed closeto the surface of thewall.15.4˚CRA (returt air)ThermalenergyOutdoor:0˚CIndoor:20˚CEAOAEAOASA (supply air)Changing the duct directionHow much recovery?OA temp. : 0˚CSA temp. : 15.4˚C(Indoor 20˚C)CollarAperture PlateExchangeableIndoor unitLOSSNAYPage 65 Page 66


UPModel line upAppearanceM-NET system with <strong>City</strong> <strong>Multi</strong>Flexible system, for your multi demandCentralized controllerOutdoor unitPower supply unitIndoor unitIndoor unitPAR-F27MEAPAR-F27MEALGH-50RX4-E LGH-200RX4-EInstallationLOSSNAY ventilation <strong>com</strong>bined with Air-conSpecificationModelPower sourceSizeL mmW mmH mmVolume m 3WeightkgDuct diameter [mm]Air Volume Shi CMHStatic Pressure Shi PaSound level A Shi dBSound level B Shi dBEx. Effciency Temp. %Heatin %Cooling %Model: LGH-RX4 series15R 25R 35R 50R 65R 80R 100R 150R 200R200/240V 1Ph 50/60Hz780 780 888 1016 954 1164 1263 1413 1413610 735 874 888 908 1004 1164 1004 1231275 275 317 317 388 398 398 800 8000.13 0.16 0.25 0.29 0.34 0.47 0.59 1.13 1.3917 21 30 33 46 61 69 138 161100 150 150 200 250 250 250 350 350150 250 350 500 650 800 1000 1500 200095 80 150 150 110 140 160 140 15026 26.5 31 33 34.5 33.5 36 36.5 3933 34.5 39 41 42.5 44.5 47 49 51.577 78 79 77 77 78 79 79 7970 70 70 67.5 67.5 71 71 72 7165.5 65 68 64.5 64.5 67 67 68 67Indoor unitLOSSNAYPage 67 Page 68


OA ProcessingUnitsRDH3 SERIESOUTDOOR AIR PROCESSING UNIT GUF typeIdeal Indoor-Air Quality — For Your Comfort and HealthGeneralThe OA (outdoor-air) Processing Unit creates an optimum indoor-air environment at an unparalleled rate of costefficiency providing substantial energy savings. Forced air ventilating and humidifying functions unique to this systemkeep indoor-air fresh and free of contaminants preventing “sick building syndrome” and the spread of airborne virusessuch as the flu. Another novel feature of the OA Processing Unit is the “Lossnay core,” a heat-exchange unit thatfunctions to transfer heat efficiently, cutting ventilation load by as much as 70%. This special <strong>com</strong>bination of functionalityand performance designed to ensure users ample <strong>com</strong>fort and year-round health which cannot be found anywhere elseon the market.GUF - For the finest indoor qualityGUF = [ LOSSNAY ] + [ HEATING & COOLING ]GUF model imageLossnay (Energy Recover)DX Coil(Heating & Cooling)OA (Outdoor air)Fresh, outdoor-air in a quantityrequired for ventilation is drawnin by the supply fan.Heat recovery unit(Lossnay Core)Temperature and humidity areexchanged between the supplyair and the exhaust air.New Permeable Film Humidifier (RDH3 model)The OA Processing Unit is equipped with a new permeable film humidifierdeveloped and patented by Mitsubishi Electric. Steam transmission efficiencyhas been improved remarkably by lowering the resistance of the material. Theuse of a 3-layer film that allows only the transfer of steam prevents theproduction of white powder, so there is no need for the use of a water purifier.Indoor unitMaintenance coverEA (Exhaust air)Heat from the indoor air (both sensibleand latent) is recovered by the LossnayCore and vented outside by theexhaust fan.Air filterPrevents clogs inthe Lossnay Core.DX Heat exchangerCools or heats the drawnin outdoor-air.The exhaust fanHigh efficiency filters (Option)The supply fanSA (Supply air)The processed, freshoutdoor-air is ventedto the indoor rooms.RA (Return air)The exhaustfan draws incontaminatedindoor-air.Comfortable Level of Humidity for ExceptionableAir QualityHighly Efficient HumidificationImprovements in the system of airflow patterns and water injection techniqueshave resulted in a substantial increase in humidifying volume.GUF-50RD(H)3 *1Cooling Capacity5.29 (DX coil:3.63, Lossnay:1.66)KWHeating capacity6.42 (DX coil:4.17, Lossnay:2.25)KW500m 3 /h Single phase 220-240V 50HzGUF-100RD(H)3 *1Cooling Capacity10.81 (DX coil:7.32, Lossnay3.49)KWHeating capacity13.00 (DX coil:8.30, Lossnay:4.70)KW1000m 3 /h Single phase 220-240V 50Hz*1 H : Humidifying TypeOutdoorairWaterUltra-waterrepellantcell-basedwater-vaportransmissionfilterWaterUltra-waterrepellantcell-basedwater-vaportransmissionfilterHumidified airSpacer3-dimensionalclothSteamNew filterSpecificationModelPower sourceCooling capacityFigure in < > is the recoverycapacity by LOSSNAY core.Power inputCurrent inputHeating capacityFigure in < > is the recoverycapacity by LOSSNAY core.Power inputCurrent inputCapacity equivalent to indoor unitHumidifying capacityHumidifierExternal finishExternal dimension H ✕ W ✕ DNet weightHeatexchangerFANNoise level (Low-High)(measured in anechoic room)Insulation materialAir filter Supplying airExhausting airProtection deviceRefrigerant control deviceDiameter ofrefrigerant pipeDiameter of drain pipeLOSSNAY coreRefrigerant coilType ✕ Quantity❇1❇1❇1❇2❇3❇3❇3Externalstatic press.Motor typeMotor outputDriving mechanismAirflow rate(High value)LiquidGaskWkcal / hBtu / hkcal / hkWAkWkcal / hBtu / hkWAkg / hlb / hmmin.kg (lb)PammH2OkWm3 / minL / scfmdB mm (in.)mm (in.)mm (in.)GUF-50RDH3 GUF-100RDH3 GUF-50RD3 GUF-100RD35.464,70018,6004,5006.185,30021,100235-2651.15235-2651.15P322.76.0317 ✕ 1,016 ✕ 1,28812-1/2 ✕ 40 ✕ 50-3/457 (126)12512.7Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2units----Direct-driven by motor50013929433.5-34.5ø6.35 (ø1/4) Flareø12.7 (ø1/2) Flare1-phase 220-240V 50Hz, 1-phase 220V 60Hz11.17 5.46 9,600 4,700 38,100 18,600 9,300 4,500 12.5010,80042,700480-5052.20480-5052.20P635.412.0398 ✕ 1,231 ✕ 1,58015-11/16 ✕ 48-1/2 ✕ 62-1/498 (217)13513.81,00013958938-39ø9.52 (ø3/8) Flareø15.88 (ø5/8) Flare235-2651.15235-2651.15P32--Permeable film humidifier -Galvanized, with grey insulation sheet317 ✕ 1,016 ✕ 1,28812-1/2 ✕ 40 ✕ 50-3/454 (120)Partition, Cross-flow structure, Special preserved paper-plate.Cross fin (Aluminum fin and copper tube)SA: Centrifugal fan (Sirocco fan) ✕ 1EA: Centrifugal fan (Sirocco fan) ✕ 114014.350013929433.5-34.5ø6.35 (ø1/4) Flareø12.7 (ø1/2) Flare480-5052.20480-5052.20P63--398 ✕ 1,231 ✕ 1,58015-11/16 ✕ 48-1/2 ✕ 62-1/492 (203)14014.31,00013958938-39Polyester sheetNon-woven fabrics filter (Gravitational method 82%) & Optional part: High efficiency filter (Colorimetric method 65%)Non-woven fabrics filter (Gravitational method 82%)FuseLEVVP256.185,30021,10011.179,60038,1009,30012.5010,80042,700ø9.52 (ø3/8) Flareø15.88 (ø5/8) FlareOA Processing UnitsPage 69 Page 70


O utdoor unitHeat Pump SeriesHeat Pump Series - High COPWater Cooled SeriesIndoor unitPage 71Page 72


Wide selection of outdoor unitsWide selection of outdoor unitsHeat Pump SeriesHeat Pump Series - High COPS Series (4HP-6HP)Page75,76Y Series (28HP-36HP)Page80,81Y Series - High COP (8HP/12HP)Page85Y Series - High COP (32HP-34HP)Page89PUMY-P VHMPUMY-P YHMPUHY-P YSHM-APUHY-EP YHM-APUHY-EP YSHM-AModel4HP5HP6HPModel NamePUMY-P100VHMPUMY-P100YHMPUMY-P125VHMPUMY-P125YHMPUMY-P140VHMPUMY-P140YHMModel 28HP 30HP 32HP 34HP 36HPModel Name PUHY-P700YSHM-A PUHY-P750YSHM-A PUHY-P800YSHM-A PUHY-P850YSHM-A PUHY-P900YSHM-AModelModel Name8HPPUHY-EP200YHM-A(-BS)12HPPUHY-EP300YHM-A(-BS)ModelModel Name32HPPUHY-EP800YSHM-A(-BS)34HPPUHY-EP850YSHM-A(-BS)Y Series (8HP-12HP)Page77Y Series (38HP)Page82Y Series - High COP (16HP-20HP)Page86Y Series - High COP (36HP)Page90PUHY-P YHM-APUHY-P YSHM-APUHY-EP YSHM-APUHY-EP YSHM-AModel8HP10HP12HPModel38HPModel16HP18HP20HPModel36HPModel NamePUHY-P200YHM-APUHY-P250YHM-APUHY-P300YHM-AModel NamePUHY-P950YSHM-AModel NamePUHY-EP400YSHM-A(-BS) PUHY-EP450YSHM-A(-BS) PUHY-EP500YSHM-A(-BS)Model NamePUHY-EP900YSHM-A(-BS)Y Series (14HP-18HP)Page78Y Series (40HP-42HP)Page82Y Series - High COP (22HP-26HP)Page87Water Cooled SeriesPUHY-P YHM-APUHY-P YSHM-APUHY-EP YSHM-AWY (Heat Pump) Series (8,10,16,20HP)PQHY-P YGM-APage91Model14HP16HP18HPModel40HP42HPModel22HP24HP26HPModel NamePUHY-P350YHM-APUHY-P400YHM-APUHY-P450YHM-AModel NamePUHY-P1000YSHM-APUHY-P1050YSHM-AModel NamePUHY-EP550YSHM-A(-BS) PUHY-EP600YSHM-A(-BS)PUHY-EP650YSHM-A(-BS)Model8HP10HP16HP20HPModel NamePQHY-P200YGM-APQHY-P250YGM-A PQHY-P400YSGM-A PQHY-P500YSGM-AY Series (20HP-26HP)Page79Y Series (44HP-50HP)Page83,84Y Series - High COP (28HP-30HP)Page88PUHY-P YSHM-APUHY-P YSHM-APUHY-EP YSHM-AModel20HP22HP24HP26HPModel44HP46HP48HP50HPModel28HP30HPModel NamePUHY-P500YSHM-A PUHY-P550YSHM-A PUHY-P600YSHM-A PUHY-P650YSHM-AModel NamePUHY-P1100YSHM-A PUHY-P1150YSHM-A PUHY-P1200YSHM-A PUHY-P1250YSHM-AModel NamePUHY-EP700YSHM-A(-BS)PUHY-EP750YSHM-A(-BS)❇The PUHY-P-YSHM-A series requires a Twinning kit (optional). Refer to the data book for details.❇The PUHY-P-YSHM-A series requires a Twinning kit (optional). Refer to the data book for details.❇Unit photos are all standard models.Outdoor unitOutdoor unitPage 73Page 74