11.07.2015 Views

S o ftw a re Te s tin g a n d P ro c e s s S im u la tio n w ith W in M O D

S o ftw a re Te s tin g a n d P ro c e s s S im u la tio n w ith W in M O D

S o ftw a re Te s tin g a n d P ro c e s s S im u la tio n w ith W in M O D

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ÒDatasheet W<strong>in</strong>MOD Configura<strong>tio</strong>n A780 w<strong>ith</strong> PROFIBUS DP and PROFINET-I/O - 11/2013W<strong>in</strong>MOD ÒMewes & PartnerSo<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> for Automa<strong>tio</strong>n <st<strong>ro</strong>ng>Te</st<strong>ro</strong>ng>chnology for····P<strong>la</strong>nn<strong>in</strong>g, Development, <st<strong>ro</strong>ng>Te</st<strong>ro</strong>ng>s<st<strong>ro</strong>ng>t<strong>in</strong></st<strong>ro</strong>ng>gValida<strong>tio</strong>n and P<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>-<strong>in</strong>spec<strong>tio</strong>nTra<strong>in</strong><strong>in</strong>g and P<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>senta<strong>tio</strong>nConsul<st<strong>ro</strong>ng>t<strong>in</strong></st<strong>ro</strong>ng>g and Chang<strong>in</strong>gW<strong>in</strong>MOD Configura<strong>tio</strong>n A780®for SIMATIC PCS7/S7w<strong>ith</strong> PROFIBUS DP & PROFINET-I/O<st<strong>ro</strong>ng>Te</st<strong>ro</strong>ng>st Worksta<strong>tio</strong>n w<strong>ith</strong> Real Automa<strong>tio</strong>n Systemsemu<strong>la</strong>ted PROFIBUS- / PROFINET Network<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>al PROFIBUS- / PROFINET NetworkSo<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>Te</st<strong>ro</strong>ng>s<st<strong>ro</strong>ng>t<strong>in</strong></st<strong>ro</strong>ng>g and P<strong>ro</strong>cess S<strong>im</strong>u<strong>la</strong><strong>tio</strong>n w<strong>ith</strong> W<strong>in</strong>MODOrder No.WA780A0T71WBX000DP2DorWBX000DP4DWBX128PN1AorWBX256PN1AWBX00024VOPROFINETS<strong>la</strong>ve NetworkPROFIBUS DP S<strong>la</strong>ve NetworkItemPROFINET Emu<strong>la</strong>tor boxPROFIBUSEmu<strong>la</strong>tor boxW<strong>in</strong>MOD Configura<strong>tio</strong>n A780Configura<strong>tio</strong>n- and driver so<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> A780 <strong>in</strong>clusive manual<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>qui<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>d PROFIBUS DP special hardwa<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>:PROFIBUS DP s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n box WM_BX_DP-2D2 channel PROFIBUS DP s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n boxPROFIBUS DP s<strong>im</strong>u<strong>la</strong><strong>tio</strong>ns box WM_BX_DP-4D4 channel PROFIBUS DP s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n box<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>qui<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>d PROFINET-I/O special hardwa<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>:W<strong>in</strong>MOD-PNIO Netbox up to 128 participants1 channel PROFINET-I/O s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n boxW<strong>in</strong>MOD-PNIO Netbox up to 256 participants1 channel PROFINET-I/O s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n boxadaptor for external electric power supply 24 voltCPUEthernetW<strong>in</strong>MODW<strong>in</strong>MODMewes & Partner GmbH · Neuendorfstr. 15 · D-16761 Hennigsdorf · <st<strong>ro</strong>ng>Te</st<strong>ro</strong>ng>l.: +49 (0)3302 / 2097-0 · Fax: -111 · http://www.w<strong>in</strong>mod.de


W<strong>in</strong>MOD Configura<strong>tio</strong>n A780 - Specifica<strong>tio</strong>nUse CasesThe W<strong>in</strong>MOD Configura<strong>tio</strong>n A780 is <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>commend for p<strong>ro</strong>jects w<strong>ith</strong>: The p<strong>ro</strong>cess-cont<strong>ro</strong>l system PCS7 (Siemens), if system-specific I/O-driver a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> used <strong>in</strong> S7 p<strong>ro</strong>jecteng<strong>in</strong>eer<strong>in</strong>g.These system-specific I/O-driver will do an extended I/O-unit analysis. Accord<strong>in</strong>gly thePROFIBUS DP s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n has to serve the detailed diagnostic <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>sponse behavior. For p<strong>ro</strong>jects w<strong>ith</strong> SIMATIC S7, if specific SIMATIC PROFIBUS DP or SIMATIC PROFINET-I/Operiphery-modules (e.g. <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>dundancy, failsafe technology, .....) has to be s<strong>im</strong>u<strong>la</strong>ted.Hardwa<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> L<strong>in</strong>k to the Automa<strong>tio</strong>n System (AS)SIMBAp<strong>ro</strong> (Siemens fieldbus-s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n, <strong>in</strong>cluded <strong>in</strong> the delivery) will generate the PROFIBUS DP<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>spectively the PROFINET-I/O structu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>, which has to be s<strong>im</strong>u<strong>la</strong>ted (w<strong>ith</strong> <strong>im</strong>port f<strong>ro</strong>m SIMATICStep7/PCS7 eng<strong>in</strong>eer<strong>in</strong>g envi<strong>ro</strong>nment by W<strong>in</strong>MOD PROFIBUS editor)The W<strong>in</strong>MOD Configura<strong>tio</strong>n so<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> A780 starts and loads the s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n structu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> on thecor<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>spond<strong>in</strong>g s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n hardwa<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> and supply a runt<strong>im</strong>e opt<strong>im</strong>ized data transfer betweens<strong>im</strong>u<strong>la</strong><strong>tio</strong>n structu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> and W<strong>in</strong>MOD System So<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>.For special modules w<strong>ith</strong> ir<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>gu<strong>la</strong>r / non-<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>gu<strong>la</strong>r signal-structu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> special signal-structu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>s can beedited and <strong>im</strong>ported (e.g. 1 byte, 1 doubleword, ...)At normal opera<strong>tio</strong>n all DP-s<strong>la</strong>ve modules a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> s<strong>im</strong>u<strong>la</strong>ted. S<strong>la</strong>ve modules can be disabled orswitched to trace-mode (data-captu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> of <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>al connected DP-s<strong>la</strong>ve modules) for diagnosticpurposes..avai<strong>la</strong>ble PROFIBUS DP s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n-p<strong>ro</strong>files a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>:- PROFIBUS DP norms<strong>la</strong>ve (standard s<strong>la</strong>ve, <strong>in</strong>dependent of the manufactu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>r, based on GSDfiles)- Siemens SIMATIC p<strong>ro</strong>file (p<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>def<strong>in</strong>ed, Siemens-p<strong>ro</strong>prietary like ET 200M, ET 200S,failsafe, <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>dundancy, ... for example)avai<strong>la</strong>ble PROFINET-I/O s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n-p<strong>ro</strong>files a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>:- PROFINET I/O norms<strong>la</strong>ve (standard s<strong>la</strong>ve, <strong>in</strong>dependent of the manufactu<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>r, based on GSDfiles)- Siemens SIMATIC p<strong>ro</strong>file (p<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>def<strong>in</strong>ed, Siemens-p<strong>ro</strong>prietary like ET 200M, ET 200S,failsafe, <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>dundancy, ... for example)W<strong>in</strong>MOD Configura<strong>tio</strong>n So<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>For the full use of 1 channel and/or multi channel s<strong>im</strong>u<strong>la</strong><strong>tio</strong>n component g<strong>ro</strong>ups or <strong>in</strong>comb<strong>in</strong>a<strong>tio</strong>n w<strong>ith</strong> other W<strong>in</strong>MOD Configura<strong>tio</strong>ns (driver like MPI, Ethernet, Modbus,INTERBUS, 3DView, DLL coupl<strong>in</strong>gs...) the W<strong>in</strong>MOD System So<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> XT is <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>qui<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>d.W<strong>in</strong>MOD System Requi<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>mentsactual W<strong>in</strong>MOD System So<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> (mo<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng> <strong>in</strong>forma<strong>tio</strong>n about System So<st<strong>ro</strong>ng>ftw</st<strong>ro</strong>ng>a<st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>under www.w<strong>in</strong>mod.de)Restric<strong>tio</strong>ns of Release of W<strong>in</strong>MOD Configura<strong>tio</strong>n A780 w<strong>ith</strong> W<strong>in</strong>MOD 7.1no support for PCI cardsSubject to technical changes.Mewes & Partner GmbHNeuendorfstr. 15 · 16761 Hennigsdorf •·Germanye-mail: W<strong>in</strong>MOD@Mewes-Partner.dehttp://www.w<strong>in</strong>mod.de<st<strong>ro</strong>ng>Te</st<strong>ro</strong>ng>l.: +49 (0)3302 / 2097-0Fax: +49 (0)3302 / 2097-111W<strong>in</strong>MOD_Config_A780_PROFIBUS _ PROFINET_en.cdr© 2013 Mewes-Partner GmbHAll rights <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>served. All used p<strong>ro</strong>duct names and trade marks <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>ma<strong>in</strong> p<strong>ro</strong>perty of their <st<strong>ro</strong>ng>re</st<strong>ro</strong>ng>spective owners.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!