Floating Timber FloorFixing InstructionsSuperQuilt is rolled out onto the concrete floor leavingenough edge overlap to protrude above the floor deck.Timber joists/battens are then laid on top of the SuperQuilt,spaced at centres to suit the particular flooring. The deckis then fixed at 200mm centres with screws 37mm into thejoists/battens.ConstructionInside SurfaceChipboard DeckJoist CavitySuperQuiltConcrete SlabGroundThickness (mm)-22.0050.0040.00150.00-U-Value tableP/A Ratio U-Value (with 50mm Cavity above) U-Value (with 100mm Cavity above)0.1 0.13 W/m 2 k 0.12 W/m 2 k0.2 0.20 W/m 2 k 0.17 W/m 2 k0.3 0.24 W/m 2 k 0.20 W/m 2 k0.4 0.26 W/m 2 k 0.22 W/m 2 k0.5 0.28 W/m 2 k 0.23 W/m 2 k0.6 0.30 W/m 2 k 0.24 W/m 2 k0.7 0.31 W/m 2 k 0.25 W/m 2 k0.8 0.32 W/m 2 k 0.26 W/m 2 k0.9 0.33 W/m 2 k 0.27 W/m 2 k1 0.34 W/m 2 k 0.27 W/m 2 k4