11.07.2015 Views

60:40 Tin-Lead Alloy Solder Data Sheet

60:40 Tin-Lead Alloy Solder Data Sheet

60:40 Tin-Lead Alloy Solder Data Sheet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical <strong>Data</strong> <strong>Sheet</strong>Multicore <strong>Solder</strong> Cored Wire Flux362 & 366June 2004ROSIN BASED CORED SOLDER WIRE FLUXESProperties of Multicore 362 and 366 solid fluxes for coredsolder wire: Good wetting on most common surfaces Two activity levels: Multicore 362 for general work andMulticore 366 for more difficult surfaces Non-corrosive Fast soldering Rosin based Halide activatedPRODUCT RANGEMulticore 362 and 366 cored wires are manufactured with arange of flux contents. Although users will normally be usingproducts with a nominal flux content of 3%.Multicore 362 and 366 cored wires are available in a variety ofalloys conforming to J-STD-006 and EN 29453 or alloysconforming to similar national or international standards. Fordetails refer to document “Properties of <strong>Alloy</strong>s used in Cored<strong>Solder</strong> Wires”. A wide range of wire diameters is available.Alternative flux contents and alloys may be manufactured tospecial order.TECHNICAL SPECIFICATIONA full description of test methods and detailed test results areavailable on request.<strong>Alloy</strong>s: The alloys used for Multicore flux cored solder wiresconform to the purity requirements of the common national andinternational standards. A wide range of wire diameters isavailable manufactured to close dimensional tolerances. Fordetails refer to document “Properties of <strong>Alloy</strong>s used in Cored<strong>Solder</strong> Wires ”.Flux: Multicore 362 and 366 solid flux leave dry and non-stickyresidues. In use its odour is typically that of rosin fluxes.TYPICAL FLUX PROPERTIESTest 362 366Acid value 170mgKOH/g 158mgKOH/gHalide content


Multicore flux cored solder wires provide fast soldering oncopper and brass surfaces as well as solder coated materials.Activity of the halide activated versions on nickel is also gooddepending on the state of oxidation of the nickel finish. The goodthermal stability of Multicore fluxes means they are also wellsuited to soldering applications requiring high meltingtemperature alloys.Cleaning: Multicore 362 and 366 cored solder wires have beenformulated to leave pale flux residues and to resist spilling andfuming.Cleaning will not be required in most situations but if necessarythis is best achieved using Multicore MCF800 Cleaner (seeseparate technical data sheet). Other proprietary solvent orsemi-aqueous processes may be suitable. Saponification maybe viable but customers must ensure that the desired level ofcleanliness can be achieved by their chosen system.HEALTH AND SAFETYWarning: The following information is for guidance only andusers must refer to the Material Safety <strong>Data</strong> <strong>Sheet</strong>s relevant tospecific Multicore 362 and 366 products before use.Health Hazards and Precautions: Inhalation of the flux fumesgiven off during soldering should be avoided. The fumes areirritating to the throat and respiratory system. Prolonged orrepeated exposure to rosin or modified rosin based flux fumesmay lead to the development of respiratory sensitisation andoccupational asthma.Multicore solder wires must always be used with suitable fumeextraction equipment to remove fumes from the breathing zoneof operators and the general work environment.<strong>Solder</strong> alloys containing lead give off negligible fume at normalsoldering temperatures up to 500C.Normal handling of lead alloy wires will not cause lead to beabsorbed through the skin. The most likely route of entry isthrough ingestion but this will not be significant if a goodstandard of personal hygiene is maintained. Eating, drinkingand smoking should not be permitted in the working area.Hands should be washed with soap and warm water afterhandling solder wire.Waste disposal: Wherever possible, waste solder wire should berecycled for recovery of metal. Otherwise it should be disposed ofaccording to local or national regulations.NoteThe data contained herein are furnished for information only and arebelieved to be reliable. We cannot assume responsibility for theresults obtained by others over whose methods we have no control.It is the user's responsibility to determine suitability for the user'spurpose of any production methods mentioned herein and to adoptsuch precautions as may be advisable for the protection of propertyand of persons against any hazards that may be involved in thehandling and use thereof. In light of the foregoing, HenkelCorporation specifically disclaims all warranties expressed orimplied, including warranties of merchantability or fitness for aparticular purpose, arising from sale or use of HenkelCorporation’s products. Henkel Corporation specificallydisclaims any liability for consequential or incidental damagesof any kind, including lost profits. The discussion herein ofvarious processes or compositions is not to be interpreted asrepresentation that they are free from domination of patents ownedby others or as a license under any Henkel Corporation patents thatmay cover such processes or compositions. We recommend thateach prospective user test his proposed application before repetitiveuse, using this data as a guide. This product may be covered byone or more United States or foreign patents or patent applications.NOT FOR PRODUCT SPECIFICATIONSTHE TECHNICAL INFORMATION CONTAINED HEREIN ARE INTENDED AS REFERENCEONLY: PLEASE CONTACT HENKEL TECHNOLOGIES FOR ASSISTANCE ANDRECOMMENDATIONS ON SPECIFICATIONS FOR THISHENKEL LOCTITE ADHESIVES LTD. , KELSEY HOUSE, WOODLANE END. HEMELHEMPSTEAD, HERTFORDSHIRE HP2 4RQ, UK, TEL. +44 1442 233 233, FAX +44 1442 269 554All trademarks, except where noted, are the property of Henkel Corp. U.S.A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!