Automax SuperNova Series

Automax SuperNova Series Automax SuperNova Series

11.07.2015 Views

Automax Actuator CodingOperating ConditionsS 0 5 0 S 0 8 L S 2 512 3 45Pressure LimitationMedia10 bar maximum working pressure.Air or non-corrosive fluid.The media should have a dew point at least10°C below the ambient operating temperature.Temperature Range Standard -30°C to +80°CLow temperature variant -50°C to +80°CHigh temperature variant -30°C to +150°CRotation(viewed from top)Pinion rotates anti-clockwise when the centrechamber supply port (RHS) is pressurised.Reverse acting options available.6 7Travel(all sizes)Average 100° total travel to provide nominal5° over travel clockwise and anti clockwise.S250/S300 models - travel stops in outwarddirection only.8Extended Travel180°, 140°, 120°. For further options consultyour local Flowserve sales operation.9 10 11Adjustable Travel StopStandard on all 90° version.Optional on 140°.Open adjustment only on 180°.1 AUTOMAX ACTUATOR CODINGS European SuperNova 050-300O-RingNylon WasherSnap RingSS Washer2 3 4 SIZE050, 063, 085, 100, 115, 125, 150, 175, 200, 250, 300Top BearingPinionO-RingBody5CDFMSTWOPERATIONSpring Return FCCW(Fail Counterclockwise)Double ActingDouble Acting, 140° Rotation, Adjustment 135°(Special Body, Double Stroke Adjustment)Double Acting, 180° RotationSpring Return FCW(Standard Fail Clockwise)Double Acting, 120° RotationDouble Acting Reverse Action(Counterclockwise Rotation)PistonCentering RingISO 5211 (Optional)TRAVEL ADJUSTMENTSTOP VIEWPiston GuideBottom BearingO-Ring6 7 SPRING CONFIGURATION04, 05, 06, 07, 08, 09, 10, 11, 128BlankLHTEMPERATUREStandard Temperature, Nitrile 'O' RingsLow Temperature, Fluorosilicon 'O' RingsHigh Temperature, Viton 'O' RingsStop Bolt AdjustmentLeft End CapAIR PORTSStop Bolt AdjustmentRight End Cap9 10 11BlankCERSVNo Special VariationSPECIAL VERSIONSCorrosive Environment, Stainless Steel Pinion andSnap RingEpoxy Coated0 to 100% Stroke AdjustmentSpecial Please Consult OfficeSpecial CoatingActuator Fail Clockwise CounterclockwiseType Position (CW) CLOSED (CCW) OPENDouble Left end cap Right end capActing stop bolt stop boltSpringLeft end cap Right end cap(CW)Return stop bolt stop boltSpringRight end cap Left end cap(CCW)Return stop bolt stop boltPlease consult I.O.M. for more information- 10 -

Complete Valve Automation SystemsWATERPROOF LIMITSWITCH BOXEXPLOSIONPROOFLIMITSWITCH BOXPOSITIONERPHAROS POSITIONINDICATORNAMUR SOLENOIDVALVENAMUR ACCESSORIESCENTERING RING(OPTIONAL)DECLUTCHABLE MANUALOVERRIDE- 11 -

<strong>Automax</strong> Actuator CodingOperating ConditionsS 0 5 0 S 0 8 L S 2 512 3 45Pressure LimitationMedia10 bar maximum working pressure.Air or non-corrosive fluid.The media should have a dew point at least10°C below the ambient operating temperature.Temperature Range Standard -30°C to +80°CLow temperature variant -50°C to +80°CHigh temperature variant -30°C to +150°CRotation(viewed from top)Pinion rotates anti-clockwise when the centrechamber supply port (RHS) is pressurised.Reverse acting options available.6 7Travel(all sizes)Average 100° total travel to provide nominal5° over travel clockwise and anti clockwise.S250/S300 models - travel stops in outwarddirection only.8Extended Travel180°, 140°, 120°. For further options consultyour local Flowserve sales operation.9 10 11Adjustable Travel StopStandard on all 90° version.Optional on 140°.Open adjustment only on 180°.1 AUTOMAX ACTUATOR CODINGS European <strong>SuperNova</strong> 050-300O-RingNylon WasherSnap RingSS Washer2 3 4 SIZE050, 063, 085, 100, 115, 125, 150, 175, 200, 250, 300Top BearingPinionO-RingBody5CDFMSTWOPERATIONSpring Return FCCW(Fail Counterclockwise)Double ActingDouble Acting, 140° Rotation, Adjustment 135°(Special Body, Double Stroke Adjustment)Double Acting, 180° RotationSpring Return FCW(Standard Fail Clockwise)Double Acting, 120° RotationDouble Acting Reverse Action(Counterclockwise Rotation)PistonCentering RingISO 5211 (Optional)TRAVEL ADJUSTMENTSTOP VIEWPiston GuideBottom BearingO-Ring6 7 SPRING CONFIGURATION04, 05, 06, 07, 08, 09, 10, 11, 128BlankLHTEMPERATUREStandard Temperature, Nitrile 'O' RingsLow Temperature, Fluorosilicon 'O' RingsHigh Temperature, Viton 'O' RingsStop Bolt AdjustmentLeft End CapAIR PORTSStop Bolt AdjustmentRight End Cap9 10 11BlankCERSVNo Special VariationSPECIAL VERSIONSCorrosive Environment, Stainless Steel Pinion andSnap RingEpoxy Coated0 to 100% Stroke AdjustmentSpecial Please Consult OfficeSpecial CoatingActuator Fail Clockwise CounterclockwiseType Position (CW) CLOSED (CCW) OPENDouble Left end cap Right end capActing stop bolt stop boltSpringLeft end cap Right end cap(CW)Return stop bolt stop boltSpringRight end cap Left end cap(CCW)Return stop bolt stop boltPlease consult I.O.M. for more information- 10 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!