11.07.2015 Views

(MT375) - Technical Description - Iskraemeco UK

(MT375) - Technical Description - Iskraemeco UK

(MT375) - Technical Description - Iskraemeco UK

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Mx37y ─ Single- and three-phase electronic meters with built-in DLCmodem, GSM/GPRS modem or RS485 comm. interface5.8. Historic reading of G-meterMeter reading for analysis, for reference, for disputeson invoices and to enable recovery of lost data, bothbilling and scheduled readings.5.9. Device statusDuring its operation, the meter performs tests ofindividual functions, and in case of an error it createsthe “Self-Test Error” event.The detected errors are represented with FF flag onthe LCD display. A corresponding error bit in the FFregister is set and an error event is recorded in eventlog. The FF register is 32 bits long. It is organized in 4groups of errors:Time base errorsAccess data errorsChecksum errorsOther errorsLIST OF ERROR STATUSESTIME BATTERY DISCHARGEDTIME INVALID-TIMEACCESS RAMACCESS FRAMACCESS MEASURECHECKSUM ROMCHECKSUM BACK UP DATACHECKSUM PARAMETERSCHECKSUM RAMLIST OF EVENTS IN EVENT LOGFATAL ERRORBILLING RESETDEVICE CLOCK CHANGEDPOWER RETURNEDPOWER FAILUREEVENT LOG CLEAREDLOAD PROFILE CLEAREDL1 POWER FAILUREL2 POWER FAILUREL3 POWER FAILUREL1 POWER RETURNEDL2 POWER RETURNEDL3 POWER RETURNEDMETER COVER OPENEDTERMINAL COVER OPENEDNO CONNECTION TIMEOUT (onlyDLC meters)PREPAY TOKEN ENTER SUCCESSPREPAY TOKEN ENTER FAILEDPREPAY CREDIT EXPIREDPREPAY EM CREDIT EXPIREDPREPAY EM CREDIT ACTIVATEDhex0x010000000x020000000x000100000x000200000x000400000x000001000x000002000x000004000x00002000hex0x00010x00100x00200x00400x00800x20000x40000x80010x80020x80030x80040x80050x80060x80100x80110x80120x80130x80140x80150x80160x80175.10. Tariff structure configuration of E-meterSetting of tariff structures with different combinationsof tiers and timeslots including the consumptionthreshold in the meter (Activity calendar, special daystable, register activation).5.11. Remote customerconnection/disconnectionA plug-in switching device (ZO3…) is used for remotedisconnection and reconnection of electric network toindividual customers.The meter controls the switching device via controloutput or via M-Bus.Control can be performed locally (from the meter) orfrom a remote control centre using the meter AMRcommunication.5.12. Load-profile reading of E-meterCollection of information saved in profiles of individualcustomers and/or a larger number of customers.COSEM ObjectsClock. Profile Status,M-Bus Ch1 Result 0 – External Meter 1 Consumption,M-Bus Ch2 Result 0 – External Meter 2 Consumption,M-Bus Ch3 Result 0 – External Meter 3 Consumption,M-Bus Ch4 Result 0 – External Meter 4 Consumption,Load Profile Period 1,Load Profile Period 2.Load-profile period 1 is used for hourly values ofconsumption and Load-profile period 2 is used fordaily values of consumption.5.13. Load-profile reading of G-meterCollection of information saved in profiles of individualcustomers and/or a larger number of customers.Load-profile period 1 is used for hourly values ofconsumption and Load-profile period 2 is used fordaily values of consumption.5.14. Load-profile configuration of E-meterRemote configuration of information saved in profilesof individual customers and/or a larger number ofcustomers.Load-profile configuration enables setting of captureperiod and capture objects of Load-profile period 1and Load-profile period 2.Mx37y_<strong>Technical</strong>_<strong>Description</strong>_ENG_v2.00.doc 27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!