(MT375) - Technical Description - Iskraemeco UK

(MT375) - Technical Description - Iskraemeco UK

(MT375) - Technical Description - Iskraemeco UK

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Mx37y ─ Single- and three-phase electronic meters with built-in DLCmodem, GSM/GPRS modem or RS485 comm. interfaceis transferred from a register for current demandperiod into a register for previous demand period andis compared with a value in a register of themaximum demand. If a new demand value is largerthan the value in the maximum demand register, it isentered into the maximum demand register,otherwise the old maximum demand value is kept. Inthis way, a maximum demand is registered at themeter billing reset.4.4. Liquid Crystal Display – LCDThe 7-segment LCD, with additional characters andsymbols, complies with the VDEW specifications.Large characters and a wide angle view enable easydata reading.Fig. 23: Liquid Crystal Display – LCDData are displayed in the right bottom corner bymeans of eight 8 mm high alphanumeric characters.The OBIS code (by IEC 62056-61) is employed fordata identification. It is displayed in the left bottomcorner by means of five 6 mm high alphanumericcharacters.An indicator of energy flow direction is displayed inthe left top corner. A physical unit of displayedquantity is shown in the right top corner. The indicatorof L1, L2 and L3 phase voltages presence isdisplayed in the middle of the top row. If certainphase voltage is not present, the indicator of thatphase is not displayed.In the LCD bottom row there are eleven signal flagsthat indicate current valid tariff, meter status andalarms. Meaning of each signal flag is engraved onthe meter name plate below each of the signal flagsin use.4.4.1. Data displayData defined in Auto scroll sequence and in Manualscroll sequence are displayed on the LCD. Data fromAuto scroll sequence are displayed in a circle - each isdisplayed for 10 sec. On request, longer data displaytime can be set. At Manual scroll sequence the bluepush-button should be pressed for displaying the nextpiece of data. Data in Manual scroll sequence remainsdisplayed until the blue push-button is pressed again oruntil time for automatic return into the Auto scrollsequence is not elapsed.Data that can be displayed are listed in the tablebellow. Which of them will be displayed depends oncustomer request at meter ordering:CODE DATA DESCRIPTION0.0.0 Meter serial numberC.1.0 Meter manufacturer number0.9.1 Time0.9.2 Date1.8.0 Total imported active energy (A+)15.8.0 Total absolute active energy |A|1.8.1 Imported active energy in the first tariff (T1)15.8.1 Absolute active energy in the first tariff |T1|1.8.2 Imported active energy in the 2-nd tariff (T2)15.8.2 Absolute active energy in the 2-nd tariff |T2|1.8.3 Imported active energy in the third tariff (T3)15.8.3 Absolute active energy in the third tariff |T3|1.8.4 Imported active energy in the fourth tariff (T4)15.8.4 Absolute active energy in the fourth tariff |T4|2.8.0 Total exported active energy (A-)2.8.1 Exported active energy in the first tariff (T1)2.8.2 Exported active energy in the 2-nd tariff (T2)2.8.3 Exported active energy in the third tariff (T3)2.8.4 Exported active energy in the 4-th tariff (T4)1.6.1 A+ import. max. demand in the first tariff (T1)1.6.2 A+ import. max. demand in the 2-nd tariff (T2)1.6.3 A+ import. max. demand in the 3-rd tariff (T3)1.6.4 A+ import. max. demand in the 4-th tariff (T4)2.6.1 A- export. max. demand in the first tariff (T1)2.6.2 A- export. max. demand in the 2-nd tariff (T2)2.6.3 A- export. max. demand in the 3-rd tariff (T3)2.6.4 A- export. max. demand in the 4-th tariff (T4)3.8.0 Reactive energy import total3.8.x Reactive energy import in tariff x4.8.0 Reactive energy export total4.8.x Reactive energy export in tariff xF.F Meter fatal error4.4.2. Signal flagsThe signal flags in the display bottom row indicatecertain meter status and alarms. The following flagsare active at the MT372 meters (depending on themeter type – RS485, GSM/GPRS, M-Bus):INDICATION STATUS MEANINGT1 Lit The first tariff is activeT2 Lit The second tariff is activeT3 Lit The third tariff is activeT4 Lit The fourth tariff is activeT1, T2,T3, T4BRSDBlinkingLitLitThe meter is in theprogram mode. Mode isaccessible when sealsfrom the meter cover areremovedBilling reset is activated. Itis lit until expiration of MDperiodSwitching device hasdisconnected a customer(contacts are open)18Mx37y_<strong>Technical</strong>_<strong>Description</strong>_ENG_v2.00.doc

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!