Mx37y ─ Single- and three-phase electronic meters with built-in DLCmodem, GSM/GPRS modem or RS485 comm. interfaceFor single phase meters BS terminal block (Imax =100 A) is possible too.2.3. Meter configuration (ME37y)2.2. Overall and fixing dimensions(ME37y)SDSDdetectioionSD - Switching deviceFig. 6: ME371 meter block diagramFig. 5a: Overall and fixing dimensions of a meter fitted witha long terminal coverSDSDdetectionGSM/GPRS MODEMorRs485 COMMUNICATION INTERFACESD - Switching deviceFig. 7: ME372 meter block diagram2.4. Metering system (ME37y)Fig. 5b: Overall and fixing dimensions of a meter fitted witha short terminal coverBesides precision measurement of active, reactive,apparent energy and demand in a wide metering andtemperature range, the metering system enablesmeasurement of phase voltages, currents and supplyquality.One metering element is built in the meter. Thecurrent sensor is shunt, while voltage sensor isresistive voltage divider. Signals of currents andvoltages are fed to the A/D converters, and then theyare digitally multiplied so that instantaneous power iscalculated. The instantaneous powers are integratedand summed in a microcontroller, as well as furtherprocessed.10Mx37y_<strong>Technical</strong>_<strong>Description</strong>_ENG_v2.00.doc