<strong>OPTIWAVE</strong> <strong>6300</strong> CPRODUCT FEATURES 11.1 The radar solution for solidsThis device is a non-contact Radar (FMCW) Level Meter for distance, level, volume and massmeasurement of powders, granulates and other solids. It gives a stabler measurement thanpulse radar and is well suited to dusty process conditions. The device can operate at very low andvery high process temperatures as long as the process connection temperature limits areobserved.1 Optional touch screen with 4-button operation2 2-wire level meter3 Removable and rotatable converter with quick connector system4 Stainless steel horn or PTFE/PP Drop antennas5 Optional flange plate protection (for corrosive products) or antenna extension (for long nozzles)6 One converter for all applications (same housing for Ex d and non-Ex)06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com3


<strong>OPTIWAVE</strong> <strong>6300</strong> CPRODUCT FEATURES 11.2 OptionsDrop antennasDrop antennas are a unique innovation to measurepowders and other solids in very dusty atmospheres.The ellipsoidal shape of the antennas preventsbuild-up and generates a small beam angle foraccurate measurement of silo contents. They havethese features:• 2 antenna sizes: DN80 or DN150.• An installation wizard specifically for solids thatpermits the instrument to measure unevensurfaces accurately.• Antennas can be extended to suit any nozzle length.• Made of either PP or PTFE.Horn antennasUse of metal horn antennas is recommended formeasuring granulates, high-pressure and hightemperatureapplications, cement works orprocesses with cyclone separators. They areparticularly resistant to mechanical shocks. Theyhave these features:• Made of stainless steel 316L.• 3 antenna sizes: DN80, DN100 or DN150.• Antennas can be extended to suit any nozzle length.06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com5


<strong>OPTIWAVE</strong> <strong>6300</strong> CTECHNICAL DATA 22.1 Technical data• The following data is provided for general applications. If you require data that is morerelevant to your specific application, please contact us or your local representative.• Additional information (certificates, special tools, software,...) and complete productdocumentation can be downloaded free of charge from the website (Download Center).Measuring systemMeasuring principleApplication rangePrimary measured valueSecondary measured value2-wire loop-powered level transmitter; K-band (24...26 GHz) FMCW radarLevel measurement of powders and granulatesΔf (change in frequency) between the emitted and received signalDistance, level, volume, mass and reflectivityDesignConstructionThe measurement system consists of a measuring sensor (antenna) and a signalconverter which is only available in a compact versionStandardAntenna purging system for horn antenna(supplied with a ¼ NPTF connection - for horn antenna only)OptionsIntegrated LCD display with sun cover (-20..+60°C /-4…+140°F);if the ambient temperature is not in these limits, the display switches off2nd current outputFOUNDATION Fieldbus output (4-wire device with local HART communication)PROFIBUS PA output (4-wire device with local HART communication)PTFE/PP flange plate protection (for Drop antenna without antenna extensions only)Distance piece (for process temperature: +150...+200°C)AccessoriesWeather protectionAntenna extensions of 105 mm / 4.1¨ length(max. length for Drop antenna versions: 525 mm / 20.7¨)2° PP slanted flange (for all antennas)Max. measuring range80 m / 260 ftDepends on the antenna option, dielectric constant of the product and installationtype. Refer also to "Antenna selection".Min. tank height0.2 m / 8¨Dead zoneAntenna extension length + antenna length + 0.3 m / 12¨Beam angle of antenna Horn DN80 / 3¨: 10°Horn DN100 / 4¨: 8°Horn DN150 / 6¨: 8° (pending)Drop DN80 / 3¨: 8°Drop DN150 / 6¨: 4°Display and user interfaceDisplayLCD display9 lines, 160 × 160 pixels in 8-step grayscale with 4-button keypadInterface languagesEnglish, German, French, Italian, Spanish, Portuguese, Japanese, Chinese(Mandarin) and Russian06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com7


2 TECHNICAL DATA<strong>OPTIWAVE</strong> <strong>6300</strong> CMeasurement accuracyResolution 1mm/ 0.04¨RepeatabilityAccuracyReference conditions acc. to EN 60770TemperaturePressure±5 mm/ ±0.2¨Relative air humidity 60% ±15%TargetOperating conditions±10 mm / ±0.4¨, when distance < 10 m / 33 ft;±0.1% of measured distance, when distance > 10 m / 33 ft+20°C ±5°C / +70°F ±10°F1013 mbara ±20 mbar / 14.69 psia ±0.29 psiMetal plate in an anechoic chamberTemperatureAmbient temperature-40…+80°C /-40…+175°F (according to the temperature limits of the gasketmaterial. Refer to "Materials" in this table.)Ex: see supplementary operating instructions or approval certificatesStorage temperature-40…+85°C /-40…+185°FFlange temperatureHorn antenna:Standard: -50…+150°C /-58…+300°FOption: -50…+200°C/-58…+390°F(the process connection temperature must agree with the temperature limits of thegasket material. Refer to "Materials" in this table.)Ex: see supplementary operating instructions or approval certificatesDrop antenna (PTFE):-50…+150°C/-58…+300°F (the process connection temperature must agree withthe temperature limits of the gasket material. Refer to "Materials" in this table.)Ex: see supplementary operating instructions or approval certificatesDrop antenna (PP):-40…+100°C/-40…+210°F (the process connection temperature must agree withthe temperature limits of the gasket material. Refer to "Materials" in this table.)Ex: see supplementary operating instructions or approval certificatesThermal shock resistance


2 TECHNICAL DATA<strong>OPTIWAVE</strong> <strong>6300</strong> CElectrical connectionsPower supply Terminals output 1 - Non-Ex / Ex i:14…30 VDC; min./max. value for an output of 22 mA at the terminalTerminals output 1 - Ex d:20…36 VDC; min./max. value for an output of 22 mA at the terminalTerminals output 2 - Non-Ex / Ex i / Ex d:10…30 VDC; min./max. value for an output of 22 mA at the terminal (additionalpower supply needed - output only)Cable entryM20×1.5; ½ NPTG ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)M25×1.5 (for stainless steel housings only)Cable glandStandard: noneOptions: M20×1.5 (for non-Ex and Ex -approved devices with M20×1.5 and M25×1.5cable entries); others are available on requestCable entry capacity (terminal) 0.5…1.5 mm²Input and outputCurrent outputOutput signal(Output 1)4…20 mA HART ® or 3.8…20.5 mA acc. to NAMUR NE 43 3Output signal(Output 2 - optional)4…20 mA (no HART ® signal) or 3.8…20.5 mA acc. to NAMUR NE 43Resolution ±3 µATemperature driftTypically 25 ppm/KError signal High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43PROFIBUS PAType4-wire (+ local HART) level transmitter; K-band FMCW radarFunction blocks7 (level, distance, level conversion, level mass, reflection, ullage conversion anddistance mass)Protocol / Communication PROFIBUS PA protocol that agrees with IEC 61158-2, galvanically isolatedstandardPhysical layer typesStandard power signaling, bus powered, non I.S.Other featuresBus interface with integrated reverse polarity protectionDevice power supply (24 V input) 18...30 VDCCurrent consumption on 20 mAPROFIBUS networkOutput dataLevel, distance, level conversion, level mass, reflection, ullage conversion ordistance massInput dataNoneError current FDETypically 0 mA (FDE =Fault Disconnection Electronic)Address range 0...125. Default address: 126.FOUNDATION FieldbusType4-wire (+ local HART) level transmitter; K-band FMCW radarFunction blocks1 × Resource Block (RB), 4 × Analog Input Blocks (AI), 1 × Transducer Block (TB)Analog Input Block: 50 msProtocol / Communication Foundation Fieldbus protocol that agrees with IEC 61158-2, galvanically isolatedstandardITK version 5.110www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CTECHNICAL DATA 2Physical layer typesOther featuresDevice power supply (24 V input)Bus power supplyBasic currentMaximum error currentStart current after 10 msPolar sensitivityMinimum cycle timeOutput dataInput dataError current FDELink Master functionStandard power signaling, bus powered, non I.S.Bus interface with integrated reverse polarity protection18...30 VDC9...32 VDC (non-Ex); 9...17.5 VDC (intrinsically-safe)20 mA20 mA20 mAYes100 msLevel, distance, level conversion, level mass, reflection, ullage conversion ordistance massNoneTypically 0 mA (FDE =Fault Disconnection Electronic)Not supportedApprovals and certificationCEThis device fulfils the statutory requirements of the EC directives. Themanufacturer certifies successful testing of the product by applying the CE mark.Explosion protectionATEXATEX II 1 G, 1/2 G, 2 G Ex ia IIC T6...T3;ATEX II 1 D, 1/2 D, 2 D Ex iaD 20 or Ex iaD 20/21 or Ex iaD 21 IP6X T70°C...T95°C;ATEX II 1/2 G, 2 G Ex d[ia] IIC T6...T3;ATEX II 1/2 D, 2 D Ex tD[iaD] A21/20 or Ex tD[iaD] A21 IP6X T70°C...T95°CIECEx (available in Q3/2010) Ex ia IIC T6…T3 Ga; Ex iaD 20 IP6X T70°C…T95°C;Ex d[ia] IIC T6…T3 Ga/Gb; Ex tD[iaD] A21/20 IP6X T70°C…T95°CFM - Dual Seal-approved NEC 500CSA - Dual Seal-approved(available in Q4/2010)NEPSICEPEL / INMETRO (pending)XP-IS: Cl. I, Div. 1, Gr. ABCD T6DIP: Cl. II/III, Div. 1, Gr. EFG T6;IS: Cl. I/II/III, Div. 1, Gr. ABCDEFG T6;NI: Cl. I, Div. 2, Gr. ABCD T6NEC 505XP-IS: Cl. I Zone 0 AEx d[ia] IIC T6...T3;IS: Cl. I Zone 0 AEx ia IIC T6...T3;NI: Cl. I Zone 2 AEx nA[ia] IIC T6...T3Temperature class: T6 Ta=60°C; T4A Ta=85°CHazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual SealCEC Section 18 (Zone ratings)Cl. I, Zone 1, Ex d, IIC (Probe: Zone 0) T6...T3;Cl. I, Zone 0, Ex ia, IIC T6...T3;Cl. I, Zone 2, Ex nA, IIC T6...T3CEC Section 18 and Annex J (Division ratings)XP-IS, Cl. I, Div. 2, Gr. ABCD; Cl. II, Div. 2, Gr. FG; Cl. III, Div. 2 T6...T3;IS, Cl. I, Div. 1, Gr. ABCD; Cl. II, Gr. FG; Cl. III T6...T3Ex dia IIC T3…T6; Ex ia IIC T3…T6BR-Ex ia IIC T3…T6; BR-Ex d[ia] IIC T3…T606/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com11


2 TECHNICAL DATA<strong>OPTIWAVE</strong> <strong>6300</strong> COther standards and approvalsEMC Electromagnetic Compatibility Directive 2004/108/EC in conjunction with EN 61326-1 (2006)R & TTEFCC Rules Part 15Industry CanadaRadio Equipment and Telecommunications Terminal Equipment Directive1999/5/EC in conjunction with ESTI EN 302 372 (2006)RSS-210LVD Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001)NAMURNAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process andLaboratory Control EquipmentNAMUR NE 43 Standardization of the Signal Level for the Failure Information ofDigital Transmitters1 Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.2 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG3 HART® is a registered trademark of the HART Communication Foundation12www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CTECHNICAL DATA 22.2 Antenna selectionThis graph shows which antenna to select for the application based on:• D, the measuring range and• ε r , is the dielectric constant of the product being measured18070460505403062010701 2 3 4 5 6 7 8 9 103Figure 2-1: Selection of antenna for solid applications (graph of distance in m against ε r )2 26024022020019018016014013012010080706040302001 2 3 4 5 6 7 8 9 10+ 3Figure 2-2: Selection of antenna for solid applications (graph of distance in ft. against ε r )1 Distance, D [m]2 Distance, D [ft]3 Dielectric constant (ε r )4 On request5 DN150 horn and DN150 Drop antenna6 DN100 horn, DN150 horn and DN150 Drop antenna7 DN80 horn, DN80 Drop, DN100 horn, DN150 horn and DN150 Drop antenna456706/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com13


2 TECHNICAL DATA<strong>OPTIWAVE</strong> <strong>6300</strong> C2.3 Dimensions and weightsHousingFigure 2-3: Housing dimensions1 Housing front view2 Housing side viewDimensions and weights in mm and kgDimensions [mm]Weights [kg]a b c d e f gHousing 180 122 158.5 182 1 167 277 155 3.31 If fitted with standard cable glandsDimensions and weights in inches and lbDimensions [inches]Weights [lb]a b c d e f gHousing 7.1 4.8 6.2 7.2 1 6.5 10.9 6.1 7.31 If fitted with standard cable glands• Cable glands are delivered on demand with non-Ex, Ex i- and Ex d-approved devices.• The diameter of the outer sheath of the cable must be 6…12 mm or 0.2…0.5¨.• Cable glands for FM- or CSA-approved devices must be supplied by the customer.• A weather protection cover is available on request with all devices.14www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CTECHNICAL DATA 2Weather protectionFigure 2-4: Dimensions of the weather protection option1 Weather protection, back view2 Weather protection, left side viewDimensions and weights in mm and kgDimensions [mm]Weights [kg]a b c dWeatherprotection1 Radius208 231.5 268 1 66 2.9Dimensions and weights in inches and lbDimensions [inches]Weights [lb]a b c dWeatherprotection1 Radius8.2 9.1 10.6 1 2.6 6.406/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com15


2 TECHNICAL DATA<strong>OPTIWAVE</strong> <strong>6300</strong> CDN80/3¨ horn antenna versionsiDimensions and weights in mm and kgThreadconnectionFlangeconnectionFigure 2-5: DN80/3¨ horn antenna versions1 DN80/3¨ horn antenna with G 1½ or 1½ NPT thread connection2 DN80/3¨ horn antenna with flange connection3 Antenna purging system (supplied with ¼ NPTF connection)Dimensions and weights in inches and lbDimensions [mm]a b c d e f h ØiWeights[kg]182 1 167 201 250 496 49 246 2 75 6.8182 1 167 201 263 480 62 217 2 75 11.1...18.91 If fitted with standard cable glands2 Additional antenna extensions of Ø39 × length 105 mm are availableThreadconnectionFlangeconnectionDimensions [inches]a b c d e f h ØiWeights[lb]7.2 1 6.5 7.9 9.8 19.5 1.9 9.7 2 3 157.2 1 6.5 7.9 10.4 18.9 2.4 8.5 2 3 24.4...41.51 If fitted with standard cable glands2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available16www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CTECHNICAL DATA 2DN100/4¨ horn antenna versionsDimensions and weights in mm and kgThreadconnectionFlangeconnectionFigure 2-6: DN100/4¨ horn antenna versions1 DN100/4¨ horn antenna with G 1½ or 1½ NPT thread connection2 DN100/4¨ horn antenna with flange connection3 Antenna purging system (supplied with ¼ NPTF connection)Dimensions and weights in inches and lbDimensions [mm]a b c d e f h ØiWeights[kg]182 1 167 201 250 565 49 315 2 95 7.2182 1 167 201 263 549 62 286 2 95 11.6...28.21 If fitted with standard cable glands2 Additional antenna extensions of Ø39 × length 105 mm are availableThreadconnectionFlangeconnectionDimensions [inches]a b c d e f h ØiWeights[lb]7.2 1 6.5 7.9 9.8 22.2 1.9 12.4 2 3.7 15.87.2 1 6.5 7.9 10.4 21.6 2.4 11.3 2 3.7 25.6...62.21 If fitted with standard cable glands2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com17


2 TECHNICAL DATA<strong>OPTIWAVE</strong> <strong>6300</strong> CDN150/6¨ Drop antenna versions (PP material option only)Figure 2-9: DN150/6¨ Drop antenna versions (PP material option only)1 DN150/6¨ Drop antenna with flange connection2 DN150/6¨ Drop antenna with thread connection3 DN150/6¨ Drop antenna with slanted flange connection4 DN150/6¨ Drop antenna, with flange plate protection optionDimensions and weights in mm and kgThread connection 1821Flange connection 1821Flange connection withslanted flange optionFlange connection withflange plate protection optionDimensions and weights in inches and lbDimensions [mm]a b c d e f h Øi j k18211821167 201 234 476 33 2422167 201 246 460 45 2142167 201 246 460 45 2142Weights[kg]144 - - 7.4144 - - 8…27.3144 10 2° 8.1…27.9167 201 246 460 45 214 144 39 - -1 If fitted with standard cable glands2 Additional antenna extensions of Ø39 × length 105 mm are available. Do not attach more than 5 antenna extensions.Thread connection 7.21Flange connection 7.21Flange connection withslanted flange optionFlange connection withflange plate protection optionDimensions [inches]a b c d e f h Øi j k7.217.216.5 7.9 9.2 18.7 1.3 9.526.5 7.9 9.7 18.1 1.8 8.426.5 7.9 9.7 18.1 1.8 8.42Weights[lb]5.7 - - 16.35.7 - - 17.6…60.25.7 0.4 2° 17.8…61.56.5 7.9 9.7 18.1 1.8 8.4 5.7 1.5 - -1 If fitted with standard cable glands2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available. Do not attach more than 5 antenna extensions.20www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CINSTALLATION 33.1 Intended useThis radar level transmitter measures distance, level, mass, volume and reflectivity ofgranulates and powders.It can be installed on silos and bunkers.3.2 Pre-installation requirementsObey the precautions that follow to make sure that the device is correctly installed.• Make sure that there is sufficent space on all sides.• Protect the signal converter from direct sunlight. If necessary, install the weather protectionaccessory.• Do not subject the signal converter to heavy vibrations. The devices are tested for vibrationand agree with EN 50178 and IEC 60068-2-6.3.3 How to prepare the silo before you install the deviceTo avoid measuring errors and device malfunction, obey these precautions.3.3.1 Theoretical data for nozzle positionFollow these recommendations to make sure that the device measures correctly.Figure 3-1: Recommended nozzle position for solids1 Position of the process fitting from the silo wall, r/2 (for DN80, DN100 or DN150 horn antennas, and DN80 or DN150Drop antennas)2 Radius of the silo, r3 The minimum measured level for a device without a 2° slanted PP flange option4 The minimum measured level for a device with a 2° slanted PP flange option06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com21


3 INSTALLATION<strong>OPTIWAVE</strong> <strong>6300</strong> CIf possible, do not install a nozzle on the silo centerline.If it is necessary to measure to the bottom of the silo, a 2° slanted flange option is available forall antennas. For more data, refer to Installation recommendations for solids on page 23.Do not put the device near to the product inlet. If the product that enters the silo touches theantenna, the device will measure incorrectly. If the product fills the silo directly below theantenna, the device will also measure incorrectly.Figure 3-2: Product inlets1 The device is in the correct position.2 The device is too near to the product inlet.Figure 3-3: More than 1 FMCW radar level meter can be operated in a siloMore than 1 FMCW radar level meter can be operated in a silo.22www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CINSTALLATION 33.4 Installation recommendations for solidsDo not install the device above objects in the silo (ladder, supports etc.). Objects in the silo cancause parasite radar signals. If there are parasite radar signals, the device will not measurecorrectly.If it is not possible to install the device on another part of the silo, do an empty spectrum scan.We recommend that you configure the device when the silo is empty.For the best device performance, the antenna should be silo-intrusive. Refer to the illustrationthat follows.Figure 3-4: General installation recommendations1 The level transmitter can continue to measure to the bottom of the silo if you tilt the device as shown in the illustration(a 2° slanted flange option is available for all antennas)2 If there are too many objects in the radar footprint, do an empty spectrum scan. Refer to the handbook for the procedure.3 Conical silo bottoms. Refer to the handbook for fine adjustment of the device.4 Radius of radar footprint (DN80 horn antenna): increments of 90 mm/m or 1.1¨/ft (5°)Radius of radar footprint (DN100 horn antenna, DN150 horn antenna and DN80 Drop antenna): increments of70 mm/m or 0.83¨/ft (4°)Radius of radar footprint (DN150 Drop antenna): increments of 35 mm/m or 0.42¨/ft (2°)06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com23


3 INSTALLATION<strong>OPTIWAVE</strong> <strong>6300</strong> C3.5 How to install the device on the silo3.5.1 How to install a device with a flange connectionEquipment needed:• Device• Gasket (not supplied)• Nuts and bolts (not supplied)• Wrench (not supplied)Requirements for flange connectionsFigure 3-5: Flange connectionFor more data, refer to the handbook.3.5.2 How to install a device with a threaded connectionEquipment needed:• Device• Gasket for G 1½ connection (not supplied)• 50 mm / 2¨ wrench (not supplied)Requirements for threaded connectionsFigure 3-6: Threaded connectionFor more data, refer to the handbook.24www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CELECTRICAL CONNECTIONS 44.1 Safety instructionsAll work on the electrical connections may only be carried out with the power disconnected. Takenote of the voltage data on the nameplate!Observe the national regulations for electrical installations!For devices used in hazardous areas, additional safety notes apply; please refer to the Exdocumentation.Observe without fail the local occupational health and safety regulations. Any work done on theelectrical components of the measuring device may only be carried out by properly trainedspecialists.Look at the device nameplate to ensure that the device is delivered according to your order.Check for the correct supply voltage printed on the nameplate.4.2 Electrical installation: outputs 1 and 2Figure 4-1: Electrical installation1 Terminal compartment cover2 Output 1: current output -3 Output 1: current output +4 Grounding terminal in the housing5 Output 2: current output -6 Output 2: current output +7 Grounding terminal between the process connection and the converterOutput 1 energizes the device and is used for HART ® communication. If the device has thesecond current output option, use a separate power supply to energize output 2.06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com25


4 ELECTRICAL CONNECTIONS<strong>OPTIWAVE</strong> <strong>6300</strong> C4.2.1 Non-Ex4.2.2 Ex i4.2.3 Ex dFigure 4-2: Electrical connections for non-Ex devices1 Power supply2 Resistor for HART ® communication3 Output 1: 14...30 VDC for an output of 22 mA at the terminal4 Output 2: 10...30 VDC for an output of 22 mA at the terminalFor electrical data for Ex i applications, refer to the Ex supplements. You can find thisdocumentation on the CD-ROM delivered with the device or it can be downloaded free of chargefrom the website (Downloadcenter).For electrical data for Ex d applications, refer to the Ex supplements. You can find thisdocumentation on the CD-ROM delivered with the device or it can be downloaded free of chargefrom the website (Downloadcenter).26www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CELECTRICAL CONNECTIONS 44.2.4 PROFIBUS PAFor electrical data for PROFIBUS PA networks, refer to the PROFIBUS PA supplement. You canfind this documentation on the CD-ROM delivered with the device or it can be downloaded free ofcharge from the website (Downloadcenter).4.2.5 FOUNDATION FieldbusFor electrical data for FOUNDATION Fieldbus networks, refer to the FOUNDATION Fieldbussupplement. You can find this documentation on the CD-ROM delivered with the device or it canbe downloaded free of charge from the website (Downloadcenter).4.3 Protection categoryThe device fulfills all requirements per protection class IP 66/67 (equivalent to NEMA type 4X(housing) and type 6P (antenna)).Make sure that the cable gland is watertight.Figure 4-3: How to make the installation agree with protection category IP 67• Make sure that the gaskets are not damaged.• Make sure that the electrical cables are not damaged.• Make sure that the electrical cables agree with the national electrical code.• The cables are in a loop in front of the device 1 so water does not go into the housing.• Tighten the cable feedthroughs 2.• Close unused cable feedthroughs with dummy plugs 3.06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com27


4 ELECTRICAL CONNECTIONS<strong>OPTIWAVE</strong> <strong>6300</strong> C4.4 Networks4.4.1 General informationThe device uses the HART ® communication protocol. This protocol agrees with the HART ®Communication Foundation standard. The device can be connected point-to-point. It can alsooperate in a multi-drop network of up to 15 devices.The device output is factory-set to communicate point-to-point. To change the communicationmode from point-to-point to multi-drop, refer to "Network configuration" in the handbook.4.4.2 Point-to-point connectionFigure 4-4: Point-to-point connection (non-Ex)1 Address of the device (0 for point-to-point connection)2 4...20 mA + HART ®3 Resistor for HART ® communication4 Power supply5 HART ® converter6 HART ® communication software28www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CELECTRICAL CONNECTIONS 44.4.3 Multi-drop networksFigure 4-5: Multi-drop network (non-Ex)1 Address of the device (n+1 for multidrop networks)2 Address of the device (1 for multidrop networks)3 4mA + HART ®4 Resistor for HART ® communication5 Power supply6 HART ® converter7 HART ® communication software4.4.4 Fieldbus networksFOUNDATION Fieldbus network (non-Ex)06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com29


4 ELECTRICAL CONNECTIONS<strong>OPTIWAVE</strong> <strong>6300</strong> CFigure 4-6: FOUNDATION Fieldbus network (non-Ex)1 Field device2 Junction box3 H1 network4 H1/HSE converter5 High Speed Ethernet (HSE)6 WorkstationIt is necessary to have a separate power supply to energize devices with the FOUNDATIONFieldbus output option (4-wire device with local HART ® connection). The FF terminal isconnected to a Fieldbus Power Hub. The 24 VDC terminal energizes the device. The power supplyis not shown in the illustration.30www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CELECTRICAL CONNECTIONS 4PROFIBUS PA/DP network (non-Ex)Figure 4-7: PROFIBUS PA/DP network (non-Ex)1 Field device2 Bus termination3 PROFIBUS PA bus segment4 Segment coupler (PA/DP link)5 PROFIBUS DP bus line6 Control system (PLC / Class 1 master device)7 Engineering or operator workstation (Control tool / Class 2 master device)It is necessary to have a separate power supply to energize devices with the PROFIBUS PAoutput option (4-wire device with local HART ® connection). The PROFIBUS PA terminal isconnected to a segment coupler. The 24 VDC terminal energizes the device. The power supply isnot shown in the illustration.06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com31


5 ORDER FORM<strong>OPTIWAVE</strong> <strong>6300</strong> C5.1 Device dataYou can help us to assist you as quickly as possible by giving us a few items of information.Then just fax them to us. Your personal consultant will contact you within 24 hours.Connection type Flange Threaded Specify standard andsize:Connection material 316L With PP or PTFEflange plate protection1 With PP slantedflange (2°)Antenna type and material Horn, 316L Drop, PP Drop, PTFEAntenna extensions forhigh nozzles 2Feedthrough/Sealing 3Outputs Without With Specify number: Standard/ FKM/FPM(-40...+200°C) Metaglas ® /FKM/FPM(-30...+200°C) Standard/Kalrez ® 6375(-20...+200°C) Metaglas ® /Kalrez ® 6375(-20...+200°C) 1 output 2 outputs 4...20 mA4...20 mA/HART ® HART ® + 4...20 mA Standard/ EPDM(-50...+150°C) Metaglas ® / EPDM(-30...+150°C) PROFIBUS PA(4-wire + local HART ® ) FOUNDATIONFieldbus(4-wire + local HART ® )Display Without With Specify language:Approvals No Ex ATEX Ex ia ATEX Ex d[ia] IECEx Ex ia 4 IECEx Ex d[ia] 4 NEPSI Ex ia NEPSI Ex dia FM IS Class 1Div. 1 (Dual Seal) 4 CSA IS Class 1Div. 1 (Dual Seal) 4 INMETROBR-Ex d[ia] 4 CSA XP-IS Class 1Div. 2 (Dual Seal) 4 FM XP-IS Class 1Div. 1 (Dual Seal) 4 INMETROBR-Ex ia 41 For devices with the Drop antenna option2 None for devices with the flange plate protection option. Max. 5 antenna extensions for devices with the Drop antennaoption. Max. 10 antenna extensions for devices with the horn antenna option.3 The temperature limits for the feedthrough and gasket materials must agree with the temperature limits of the antennatype.4 Pending32www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CORDER FORM 55.2 Rating dataProduct name:Operating pressure:Rated pressure:5.3 Contact dataProcess connectiontemperature:Ambient temperature:Operating density:Measurand (level,volume,...):Silo height:Comments (indoors,exposed to weather, ...):Company:Contact person:Telephone number:Fax number:E-mail:06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com33


6 NOTES<strong>OPTIWAVE</strong> <strong>6300</strong> C34www.krohne.com06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en


<strong>OPTIWAVE</strong> <strong>6300</strong> CNOTES 606/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 enwww.krohne.com35


KKKKROHNE product overview© KROHNE 06/2010 - 4000305603 - TD <strong>OPTIWAVE</strong> <strong>6300</strong> R03 en - Subject to change without notice.• Electromagnetic flowmeters• Variable area flowmeters• Ultrasonic flowmeters• Mass flowmeters• Vortex flowmeters• Flow controllers• Level meters• Temperature meters• Pressure meters• Analysis products• Measuring systems for the oil and gas industry• Measuring systems for sea-going tankersHead Office KROHNE Messtechnik GmbHLudwig-Krohne-Str. 5D-47058 Duisburg (Germany)Tel.:+49 (0)203 301 0Fax:+49 (0)203 301 10389info@krohne.deThe current list of all KROHNE contacts and addresses can be found at:www.krohne.com