11.07.2015 Views

EN7.pdf - WALDNER Inc.

EN7.pdf - WALDNER Inc.

EN7.pdf - WALDNER Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Secuflow EN7 bench-mounted fume cupboard• for high thermal loadsThe Secuflow is especially successful because it canbe operated with lower extract air volumes, whichmeans considerable saving in energy costs and inthe investment costs for the ventilation system. TheSecuflow is the safest and most ecologically soundvariant.We have developed the Secuflow EN7 to securethese benefits also for working with high thermalloads. Due to its sophisticated supply and extractair flow, the fume cupboard secures safe operationwhen working with thermal loads, whilst retaining allthe benefits of the supportive flow fume cupboardSecuflow.When the laboratory is equipped with SecufowEN7 fume cupboards, the user is ideally equipped forany kind of laboratory work: whether this is normaloperation or working with thermal loads.Secuflow EN7 bench-mounted fumecupboards for high thermal loadsIntended use• For work with high thermal loads in the inside of the fumecupboard (Heat sources of 4 KW per meter inner width of thecupboard)• Protective device for the user, tested in accordance withEN 14175-7:2012• Extraction of fumes, aerosols and dust from the internalworkspace to prevent dangerous amounts of pollutants fromescaping into the laboratory• To prevent the formation of dangerous potentially explosiveatmospheres in the internal workspace• Protection from splashes of hazardous substances• Protection from flying particles, bodies or parts escaping fromthe internal workspace• General fume cupboards constructed in acc. with EN14175 are not suited for use with radioactive substances ormicroorganisms• Not suitable for openly breaking down chemicals• Active supportive flow technology (Secuflow technology)reduces the energy consumption while regulations andstandards are observed• Service outlets for sanitary supply in the rear panel of the internalworkspace• Control units located horizontally on the service rail of thesupport unitTechnical dataDimensions 1200 1500 1800Width [mm] 1200 1500 1800Depth [mm] 900Height [mm 2700Clear width, internal workspace [mm] 1150 1450 1750Clear height, internal workspace [mm] 1550Working height [mm] 900

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!