11.07.2015 Views

Data Sheet O2S-FR-T2-18X Oxygen Sensors - Screw Fit Probe

Data Sheet O2S-FR-T2-18X Oxygen Sensors - Screw Fit Probe

Data Sheet O2S-FR-T2-18X Oxygen Sensors - Screw Fit Probe

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Data</strong> <strong>Sheet</strong><strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-<strong>18X</strong> <strong>Oxygen</strong> <strong>Sensors</strong> - <strong>Screw</strong> <strong>Fit</strong> <strong>Probe</strong>FEATURES• <strong>Oxygen</strong> pressure range 2 mbar - 3bar• Zirconium dioxide (ZrO 2 ) sensing elements• Non-consumption technology• Integral heating element• No need for temperature stabilisation• No reference gas required• High accuracy<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18A• Linear output signal• Operates with external interface boards• M18x1.5 screw mountSPECIFICATIONSELECTRICAL CONNECTIONHeater Voltage*Stand by4.35V DC ± 0.1V DC (1.85A)2V DC (0.85A)Molex ConnectorPump resistance @ 700°C**< 6kΩPermissible gas temperature -100 to 250°CGas flow rate0 to 10 m/s1: Pump (Red)2: Common (Black)3: Heater (Yellow)4: Sense (Blue)5: Heater (Yellow)Repetitive permissible acceleration5 gIncidental permissible acceleration30 g* It is important to measure the heater voltage as close to the sensoras possible due to voltage drops in the supply cable. Heater can alsobe operated with an equivalent a.c. or PWM signals.** The constant current source used in the pump circuit should bedesigned to drive a load of up to 6kΩFor detailed information on the sensor operation pleaserefer to the following application note: AN0043 OperationPrinciple and Construction of Zirconium Dioxide<strong>Oxygen</strong> Sensor.


<strong>Data</strong> <strong>Sheet</strong><strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-<strong>18X</strong> <strong>Oxygen</strong> <strong>Sensors</strong> - <strong>Screw</strong> <strong>Fit</strong> <strong>Probe</strong>OUTLINE DRAWINGSee ordering information pg 3Full Porous Cap(Length 15mm)Molex ConnectorMass: 45gMolex mating connector39-01-2061 (plastic plug)39-00-0041 (pins)X = 55mm for <strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18AX = 45mm for <strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18BX = 28mm for <strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18CAll dimensions in mm.Sensor lengths are approximate.


<strong>Data</strong> <strong>Sheet</strong><strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-<strong>18X</strong> <strong>Oxygen</strong> <strong>Sensors</strong> - <strong>Screw</strong> <strong>Fit</strong> <strong>Probe</strong>PERFORMANCE CHARACTERISTICCharacteristics Min. Typ. Max. Unit<strong>Oxygen</strong> pressure range 2 3000Accuracy 5Internal operational temperature 700 (4.35V DC ) °CResponse time (10-90% step) 4Warm up time (prior to sensor operation) 100Warm up time (from stand by) 20Output stabilisation time ~180mbarsORDERING INFORMATIONPart number Housing Termination<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18A<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18A-002<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18A-003<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18B<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18B-002<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18B-003<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18C<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18C-002<strong>O2S</strong>-<strong>FR</strong>-<strong>T2</strong>-18C-003<strong>Probe</strong> with M18 x 1.5 nutX = 55mm<strong>Probe</strong> with M18 x 1.5 nutX = 45mm<strong>Probe</strong> with M18 x 1.5 nutX = 28mm0.15m Cable with Molex Connector0.3m Cable with Molex Connector1.1m Cable with Molex Connector0.15m Cable with Molex Connector0.3m Cable with Molex Connector1.1m Cable with Molex Connector0.15m Cable with Molex Connector0.3m Cable with Molex Connector1.1m Cable with Molex ConnectorWARNINGPersonal InjuryDO NOT USE these products as safety orEmergengy Stop devices or in any other applicationWhere failure of the product could result inPersonal injury.Failure to comply with these instructions couldResult in death or serious injury.CAUTIONDo not exceed maximum ratings and ensure sensor isoperated in accordance with all requirements of AN0043Failure to comply with these instructions may resultin product damage.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!