11.07.2015 Views

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Block Diagram of the Tiger 320 Software and Hardware StructureP and UP Buttonsto enter setupmenu.PROGRAM LOCKIf Program lock is ON values aredisplayed, but cannot be changedSERIAL COMMUNICATIONRead and write into all registersCALP and DOWNButtons to entersetpoint menu.VIEW MODEto viewselectedfunction valuesRESETwith UP/DOWNPeak, Valley,Tare, TotalizersON DEMAND CALFUNCTIONSHold down thePROGRAMbutton for 4 secsto initiate Autotare, AutoCalibration,Manual Loader orInput ChannelCompensationProgPROGRAMBUTTONMACRO_PROCESSING<strong>Inc</strong>ludingE<strong>DI</strong>T MACROF1_BUTTONMACRO_PROCESSINGF2_BUTTONMACRO_PROCESSINGF3_BUTTONMACRO_PROCESSINGF1 F2 F3FLASHRegisters 5120 to 614416 bit unsigned. May beaccessed by macros orSerial Port.SETPOINT LOCKIf Program lock is ON values aredisplayed, but cannot be changed6144 REGISTERSRegisters are comprised of 8, 16 or32 bit signed, unsigned or floatingpoint registers, implemented in eitherFlash RAM, RAM, FeRAM, EEPROMor NVRAM (Real time clock option).See the Register Supplement fordetailed information on ALL registersAll registers may be accessed, andread or written to via the serial port,and by user developed macros.The registers used for the operatingsystem should not be written into, asmodification of their data may renderthe meter inoperative.Registers 1 to 244Registers from 1 to 244 may be selectedmanually as a data source for setpointor output processing. However onlythose registers shown below containdata applicable for use as data source.Setpoints6 to 11- SP1,2,3,4,5,6 value65 to 70- SP1,2,3,4,5,6 Hysteresis,71 to 76- delay on make SP1,2,3,4,5,677 to 82- delay on break SP1,2,3,4,5,6Input Channels18,19,20,41,42- Raw Result,CH1,2,3,421 to 23,43,44- Scaled Result,CH1,2,3,445,46- Prescaler CH1,2Smart modules54 to 60- Smart Output 1,2,3,4,5,6,7Analog Outputs83, 84 - Analog Output 1 & 2Variables (Used with Macro Only)85 to 94 - Variable 1 to Variable 10Timers95 & 96 - Timer 1, 2Real time Clock213 to 219 - Real Time ClockAuto Zero Offset227 to 231 - Auto Zero Offset for Result,CH1, CH2, CH3 & CH4Operating SystemNOT USABLE as a data source.15,38,47,48,52,53,61-64,123-128,140,141,160,161,234-244Registers 257 to 512Linearization24 bit registers in EEPROM that storethe four 32 point LIN tables.Registers 513 to 1124Multi function, multi type Registersthat may only be accessed throughthe serial port or by macros. Theirfunctions are detailed in the RegisterSupplement.Registers 1125 to 2048OPERATING SYSTEM USE ONLYDO NOT write to these registers, asany alteration to their data may makethe meter inoperative.Registers 2049 to 4096Macro Code Storage16 bit unsigned. In Flash RAMRegisters 4097 to 5120OPERATING SYSTEM USE ONLYDO NOT write to these registers, asany alteration to their data may makethe meter inoperative.<strong>DI</strong>SPLAY FORMATTINGI 2 CBUS<strong>DI</strong>SPLAY DRIVECode1BRIGHTNESS, ANNUNCIATORS, TRENDCUSTOM TEXT FOR CH1, 2, 3, 4, RESULT, PEAK, VALLEY,TOTALIZER 1, TOTALIZER 2, SP1, SP2, SP3, SP4, SP5, SP6SCALE, OFFSET FOR CH1, 2, 3, 4 AND RESULTLOG BARGRAPH <strong>DI</strong>SPLAY, dB <strong>DI</strong>SPLAY, OCTAL.DECIMALS, , RIGHT HAND CHARACTER, AND ROUN<strong>DI</strong>NGFOR CH1, 2, 3, 4, RESULT AND DEFAULT <strong>DI</strong>SPLAYDEFAULT<strong>DI</strong>SPLAYCHANNEL D R 1 2 3 4Select data source forOUTPUT PROCESSINGSelect data source for: Setpoint 1, 2, 3, 4, 5, 6;Analog output 1, 2; <strong>Data</strong> loggingSelect from R, 1, 2, 3, 4, Totalizer 1, 2, Peak,Valley, Tare or any usable registers from 1 to 244DEFAULT<strong>DI</strong>SPLAYCHANNEL DRESULTCHANNEL RResult of CrossChannel Math RCross Channel Math1+2, 1-2, 1x2, 1/2, 1=R1 2RAW DATAPrescalerChannel 1 & 2LOGIC I/OFROMMODULESR11CHANNELS 1 22 3 4Select data source forCode1<strong>DI</strong>SPLAY PROCESSINGSelect data source for:Display 1 (Default Display Channel D), Display 2,Display 3, Peak, Valley, Totalizer 1, Totalizer 2,Select from R, 1, 2, 3, 4, Totalizer 1, 2, Peak,Valley, Tare or any usable registers from 1 to 2442 3 4RESULT PROCESSINGof Cross Channel MathAVERAGING, CALIBRATION (SCALE & OFFSET),INVERSE of R, LOG OF R (Bargraph display only)LINEARIZING of R,SMART AUTO ZERO,SQUARE ROOT of R,3 4<strong>DI</strong>GITAL PROCESSINGAVERAGING,CALIBRATION (SCALE and OFFSET),INVERSE OF INPUT, LINEARIZATION,LOG OF INPUT (Bargraph display only)RTD, SAMPLE RATE, SMART AUTO ZERO,SQUARE ROOT, THERMOCOUPLESCHANNELS 1 2 3 417 BIT ON BOARDDUAL SLOPE A to DREF INSPC_1 to 6Code7CALCode2Code4Code5Code6CALANALOG, <strong>DI</strong>GITALAND LOGIC I/OASCII, MODBUS, DEVICENETMeter TO Meter Communication,ETHERNET (TCP/IP), Epson CompatibleSerial Printer DriverDATA LOGGING Code8Manual or auto, Up to 4000samples, Date and Timestamp, endless loop record,Burst downloadingSETPOINTS SPC_1 to 6Up to 6 relay, SSR,TTL or open collector.PID, deviation, trigger, pulse,tracking, hysteresis, latching,timer modes, reset,High/low/deviation activationPLUG IN OPTO-ISOLATE<strong>DI</strong>/O 6 IN 6 OUT OR 6 IN 16 OUTANALOG OUTPUTVoltage or current,single or dualMACRO PROCESSINGA macro can access all functions and readand write into all registers. Macro Timer1,Macro Timer2 have 0.1 second resolution.Macros allow a user to customize the meterfor a specific application using the Tiger 320Development system.Macros may be locked to prevent access byanyone.LinearizingCAL4 Tables of 32 Points eachor 1 Table of 125 PointsTOTALIZER 1CALTOTALIZER 2Two independent totalizersOptional Real-time clockwith date and time stampCALCALInternal System ClockDownloads from Real Time Clockor starts from 12:00 on power up.Can be displayed on CH3, CH4RESIDENT TIMER 1 Code5RESIDENT TIMER 2 Code6Runs ONLY if selected on CH3,or CH4. Resolution 1 secRear PinsCode9Hold, Test, Lock & Capture.The Lock, Hold and Capturepins can be reprogrammedfor use as Digital Logic I/O pins.SP1SP2SP3SP4SP5SP6I 2 CI 2 CMICROSigma DeltaA to D16 to 24 BitREFREFSigConMICROREFSigConPULSEMUXREFSignalConditioningREFREFSignalConditioningSSRSSRSignalConditioningSSR SSRSignalConditioningZEROSPANSMART MODULES WITH MULTICHANNEL INPUTS,AN ON-BOARD A TO D CONVERTER,MICROPROCESSOR, AND TWOSOLID STATE RELAY OUTPUTSSMART MODULES WITH AN ON BOARDMICROPROCESSOR AND TWO SOLID STATERELAY OUTPUTS WITH PULSE, OR QUADRATUREENCODER INPUTS FOR COUNTING, FREQUENCY OR POSITIONMULTI-INPUT MODULESW/<strong>DI</strong>GITAL SCALINGSINGLE INPUT MODULESWITH ANALOG SCALING12-30-02 4:00 PM21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300) Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.comPage 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!