11.07.2015 Views

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

++ONONONI-Series Input Signal Conditioning Modules continuedNAMUR Sensor Connected to IF10TIGERNAMURINPUT+24VGNDSensor Resistance is< 1KΩ or > 7KΩ COUNTER UP/DOWNSensor Output is< 1mA or > 3mAHigh Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACCOUPLINGDCMAG/ACINPUT SIGNAL FILTERLOGICCOUNTFRQCH2330BdIH01: pHIH02: pH with Automatic Temperature CompensationTIGERpH ProbeBNCConnectorPt-100ΩRTD3 wirePins 1-3 presentonly for IH02pH144<strong>DI</strong>P10: Process + 3 Digital InputsTIGERCH1PROCESS INPUT20 / 10 / 5 / 2 VOR2 / 20 mA+ INPUT 1+ 24 V EXC 1– INPUT 1+ 24 V EXCCOUNTER / FREQ / STATUS D1COUNTER / FREQ / STATUS D2STATUS D2GNDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8SINKSRCEOFFOFFOFFFILTER2mA20mACSTM2V5V10V20VCSTM+COUNTFREQ314DPNP Open Collector Proximity Switch Connected to IF10IOR1: ORP (Oxidation Reduction Potential)IPT1: Prototype Board for Custom DesignINPUT+24VPNPTIGEROpen CollectorGNDProximity SwitchCOUNTER UP/DOWNNormally Pin 1 is at 0VWhen sensor is activated Pin 1 goes to 24VHigh Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACCOUPLINGDCMAG/ACINPUT SIGNAL FILTERLOGICCOUNTFRQCH2330BeTIGERORP ProbeBNCConnectorORP144DTIGERLEOPARDLYNX246810121416181357911131517195CSwitch or Dry Contact Connected to IF10TIGERSwitch orDry ContactINPUT+24VGNDCOUNTER UP/DOWNWhen switch is open, Pin 1 is at 24VWhen switch is closed, Pin 1 goes to 0VHigh Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACINPUT SIGNAL FILTERCOUPLINGDCMAG/ACLOGICCOUNTFRQCH2330BfIP01: Process Loop, 4-20mAIP02: Process Loop, 4-20mA with 24VDC EXCTIGERLEOPARDLYNXOther devices can beadded to the loop.+ _24V CommonExternalLoop SupplyFully User ScalablePIN 2< Decrease Zero <strong>Inc</strong>rease >< Decrease Span <strong>Inc</strong>rease >Offset24V EXC0_ONOFFHIRangeLO091EIQD1: Quad DC Volts, 2V DCIQD2: Quad DC mV, 50mV DCTIGERQUAD DC VOLTS or mV+ Volts or mV (CH1)PIN 1+ Volts or mV (CH2)PIN 2PIN 3+ 24V ExcPIN 4+ Volts or mV (CH3)PIN 5+ Volts or mV (CH4)PIN 6168DMagnetic Pickup Connected to IF10IP03: Process Input, 1-5V DC with Offset, 24V ExcIQP1: Quad 4 to 20mATIGERMagneticPickupShieldShieldINPUT+24VGNDCOUNTER UP/DOWN(Always use shielded wire)High Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACINPUT SIGNAL FILTERCOUPLINGDCMAG/ACLOGICCOUNTFRQCH2330BgTIGERIP07LEOPAR<strong>DI</strong>PO7LYNX4/20mA250ΩPROCESS 1 to 5V DC+ 1 to 5V Input1 to 5V CommonPIN 2_+24 VFully User Scalable< Decrease Zero <strong>Inc</strong>rease >< Decrease Span <strong>Inc</strong>rease >Offset24V EXC0_ONOFFHIRangeLO091ECH1TIGERCH24 to 20mA4 to 20mA+ 24V Exc4 to 20mACH34 to 20mACH4QUAD 4 to 20mAPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6168<strong>DI</strong>GYX: Direct Pressure (Absolute or Differential/Gage)with 2 Digital Inputs. See below for ordering code optionsTIGERSINGLE or<strong>DI</strong>FFERENTIALPRESSUREINPUT(CH1)Conditioned FREQ / CNTR (CH2)and STATUS INPUT (D1)Conditioned STATUS INPUT (D2)+24 V EXCGNDPIN 4MVTTLREQNTR317CIP06: Process Loop, 4-20mA w/24VDC Exc and AutocalTIGEROther devices can beadded to the loop.24V ExcN.O.AUTOCALN.O.Fully User Scalable24V EXCOFFONVOLTAGECURRENTUNIVERSAL PROCESSCustom2mA20mA200V20V10V5V2V224<strong>DI</strong>QT2: Quad RTD Platinum 100Ω RTD2 Wire ConnectionTIGERCH1100Ω Pt RTDCH2100Ω Pt RTDCH3100Ω Pt RTDCH4100Ω Pt RTDAll four RTDs must be connected for the meter to work.CH1 CH22 Wire4 WireCH3 CH4236CIGYY: Dual Direct Pressure (Absolute or Differential/Gage)see below for ordering code optionsTIGERSINGLE or<strong>DI</strong>FFERENTIALPRESSUREINPUT(CH1)SINGLE or<strong>DI</strong>FFERENTIALPRESSUREINPUT(CH2)343BIP07: Universal Process Input2V/5V/10V/20V/200V/2mA/20mA/CustomTIGERLEOPARDLYNXFX-B101QProcess inputHILO24VExcRequires Digital Calibration24V EXCOFFCURRENTVOLTAGEONUNIVERSAL PROCESSCustom2mA20mA200V20V10V5V2V224CIQT4: Quad RTD Platinum 100Ω RTD4 Wire ConnectionTIGERCH1100Ω Pt RTDCH2100Ω Pt RTDCH3100Ω Pt RTDCH4100Ω Pt RTDAll four RTDs must be connected for the meter to work.CH1 CH22 Wire4 WireCH3 CH4236CIGYZ: Universal Direct Pressure (Absolute or Differential/Gage)See below for ordering code optionsTIGERLEOPARDLYNXABSOLUTE / <strong>DI</strong>FFERENTIALPRESSURE332DOrdering Code Options for Direct Pressure (IGYX, IGYY & IGYZ)I G For Single Channel IGYX withtwo digital inputs, the last digitSensor Range1 psi Absolute1 psi Differential5 psi Absolute5 psi Differential15 psi Absolute15 psi Differential30 psi Absolute30 psi Differential100 psi Absolute100 psi DifferentialCH1Order CodeABCDEFGHJKof order code is always X.CH2Order Code For Universal Direct PressureAIGYZ, the last digit of orderBC code is always Z.DEFGHJKIP08: Universal Process Input with Autocal2V/5V/10V/20V/200V/2mA/20mA/CustomTIGERProcess inputHI24VExcLON.O.AUTOCALN.O.24V EXCOFFONVOLTAGECURRENTUNIVERSAL PROCESSCustom2mA20mA200V20V10V5V2VIP09: 4-20mA with External LIN Table SelectTIGER4-20mALIN TABLESelect 1LIN TABLESelect 24-20mA/W EXT LIN TABLE SELECTOffset+ 0 –< <strong>Inc</strong>rease Span Decrease >224D143AIQT5: Quad RTD / V / V / FREQ173FPT 100 Ω RTD (CH1)TIGER PIN 1PIN 2PIN 3+ V (CH3)PIN 4OV (CH3)PIN 5+V (CH4)PIN 6OV (CH4)PIN 7+24 V EXCPIN 8FREQ/CNTR INPUT (CH2)PIN 9GND (AC mV)PIN 10GND (TTL, PNP, NPN)PIN 11MVTTL NPNPNP OFF ON FILTERIR01: Resistance, 2/3/4-Wire, 200Ω/ 2KΩ/20KΩ128ARESISTANCEITIGERI20K 2K 200ΩPage 52Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.com21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!