++ONONONI-Series Input Signal Conditioning Modules continuedNAMUR Sensor Connected to IF10TIGERNAMURINPUT+24VGNDSensor Resistance is< 1KΩ or > 7KΩ COUNTER UP/DOWNSensor Output is< 1mA or > 3mAHigh Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACCOUPLINGDCMAG/ACINPUT SIGNAL FILTERLOGICCOUNTFRQCH2330BdIH01: pHIH02: pH with Automatic Temperature CompensationTIGERpH ProbeBNCConnectorPt-100ΩRTD3 wirePins 1-3 presentonly for IH02pH144<strong>DI</strong>P10: Process + 3 Digital InputsTIGERCH1PROCESS INPUT20 / 10 / 5 / 2 VOR2 / 20 mA+ INPUT 1+ 24 V EXC 1– INPUT 1+ 24 V EXCCOUNTER / FREQ / STATUS D1COUNTER / FREQ / STATUS D2STATUS D2GNDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8SINKSRCEOFFOFFOFFFILTER2mA20mACSTM2V5V10V20VCSTM+COUNTFREQ314DPNP Open Collector Proximity Switch Connected to IF10IOR1: ORP (Oxidation Reduction Potential)IPT1: Prototype Board for Custom DesignINPUT+24VPNPTIGEROpen CollectorGNDProximity SwitchCOUNTER UP/DOWNNormally Pin 1 is at 0VWhen sensor is activated Pin 1 goes to 24VHigh Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACCOUPLINGDCMAG/ACINPUT SIGNAL FILTERLOGICCOUNTFRQCH2330BeTIGERORP ProbeBNCConnectorORP144DTIGERLEOPARDLYNX246810121416181357911131517195CSwitch or Dry Contact Connected to IF10TIGERSwitch orDry ContactINPUT+24VGNDCOUNTER UP/DOWNWhen switch is open, Pin 1 is at 24VWhen switch is closed, Pin 1 goes to 0VHigh Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACINPUT SIGNAL FILTERCOUPLINGDCMAG/ACLOGICCOUNTFRQCH2330BfIP01: Process Loop, 4-20mAIP02: Process Loop, 4-20mA with 24VDC EXCTIGERLEOPARDLYNXOther devices can beadded to the loop.+ _24V CommonExternalLoop SupplyFully User ScalablePIN 2< Decrease Zero <strong>Inc</strong>rease >< Decrease Span <strong>Inc</strong>rease >Offset24V EXC0_ONOFFHIRangeLO091EIQD1: Quad DC Volts, 2V DCIQD2: Quad DC mV, 50mV DCTIGERQUAD DC VOLTS or mV+ Volts or mV (CH1)PIN 1+ Volts or mV (CH2)PIN 2PIN 3+ 24V ExcPIN 4+ Volts or mV (CH3)PIN 5+ Volts or mV (CH4)PIN 6168DMagnetic Pickup Connected to IF10IP03: Process Input, 1-5V DC with Offset, 24V ExcIQP1: Quad 4 to 20mATIGERMagneticPickupShieldShieldINPUT+24VGNDCOUNTER UP/DOWN(Always use shielded wire)High Accuracy Digital Measurement4LOADMAGNAMURSOURCESINK20KHz2KHz200HzOFFACINPUT SIGNAL FILTERCOUPLINGDCMAG/ACLOGICCOUNTFRQCH2330BgTIGERIP07LEOPAR<strong>DI</strong>PO7LYNX4/20mA250ΩPROCESS 1 to 5V DC+ 1 to 5V Input1 to 5V CommonPIN 2_+24 VFully User Scalable< Decrease Zero <strong>Inc</strong>rease >< Decrease Span <strong>Inc</strong>rease >Offset24V EXC0_ONOFFHIRangeLO091ECH1TIGERCH24 to 20mA4 to 20mA+ 24V Exc4 to 20mACH34 to 20mACH4QUAD 4 to 20mAPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6168<strong>DI</strong>GYX: Direct Pressure (Absolute or Differential/Gage)with 2 Digital Inputs. See below for ordering code optionsTIGERSINGLE or<strong>DI</strong>FFERENTIALPRESSUREINPUT(CH1)Conditioned FREQ / CNTR (CH2)and STATUS INPUT (D1)Conditioned STATUS INPUT (D2)+24 V EXCGNDPIN 4MVTTLREQNTR317CIP06: Process Loop, 4-20mA w/24VDC Exc and AutocalTIGEROther devices can beadded to the loop.24V ExcN.O.AUTOCALN.O.Fully User Scalable24V EXCOFFONVOLTAGECURRENTUNIVERSAL PROCESSCustom2mA20mA200V20V10V5V2V224<strong>DI</strong>QT2: Quad RTD Platinum 100Ω RTD2 Wire ConnectionTIGERCH1100Ω Pt RTDCH2100Ω Pt RTDCH3100Ω Pt RTDCH4100Ω Pt RTDAll four RTDs must be connected for the meter to work.CH1 CH22 Wire4 WireCH3 CH4236CIGYY: Dual Direct Pressure (Absolute or Differential/Gage)see below for ordering code optionsTIGERSINGLE or<strong>DI</strong>FFERENTIALPRESSUREINPUT(CH1)SINGLE or<strong>DI</strong>FFERENTIALPRESSUREINPUT(CH2)343BIP07: Universal Process Input2V/5V/10V/20V/200V/2mA/20mA/CustomTIGERLEOPARDLYNXFX-B101QProcess inputHILO24VExcRequires Digital Calibration24V EXCOFFCURRENTVOLTAGEONUNIVERSAL PROCESSCustom2mA20mA200V20V10V5V2V224CIQT4: Quad RTD Platinum 100Ω RTD4 Wire ConnectionTIGERCH1100Ω Pt RTDCH2100Ω Pt RTDCH3100Ω Pt RTDCH4100Ω Pt RTDAll four RTDs must be connected for the meter to work.CH1 CH22 Wire4 WireCH3 CH4236CIGYZ: Universal Direct Pressure (Absolute or Differential/Gage)See below for ordering code optionsTIGERLEOPARDLYNXABSOLUTE / <strong>DI</strong>FFERENTIALPRESSURE332DOrdering Code Options for Direct Pressure (IGYX, IGYY & IGYZ)I G For Single Channel IGYX withtwo digital inputs, the last digitSensor Range1 psi Absolute1 psi Differential5 psi Absolute5 psi Differential15 psi Absolute15 psi Differential30 psi Absolute30 psi Differential100 psi Absolute100 psi DifferentialCH1Order CodeABCDEFGHJKof order code is always X.CH2Order Code For Universal Direct PressureAIGYZ, the last digit of orderBC code is always Z.DEFGHJKIP08: Universal Process Input with Autocal2V/5V/10V/20V/200V/2mA/20mA/CustomTIGERProcess inputHI24VExcLON.O.AUTOCALN.O.24V EXCOFFONVOLTAGECURRENTUNIVERSAL PROCESSCustom2mA20mA200V20V10V5V2VIP09: 4-20mA with External LIN Table SelectTIGER4-20mALIN TABLESelect 1LIN TABLESelect 24-20mA/W EXT LIN TABLE SELECTOffset+ 0 –< <strong>Inc</strong>rease Span Decrease >224D143AIQT5: Quad RTD / V / V / FREQ173FPT 100 Ω RTD (CH1)TIGER PIN 1PIN 2PIN 3+ V (CH3)PIN 4OV (CH3)PIN 5+V (CH4)PIN 6OV (CH4)PIN 7+24 V EXCPIN 8FREQ/CNTR INPUT (CH2)PIN 9GND (AC mV)PIN 10GND (TTL, PNP, NPN)PIN 11MVTTL NPNPNP OFF ON FILTERIR01: Resistance, 2/3/4-Wire, 200Ω/ 2KΩ/20KΩ128ARESISTANCEITIGERI20K 2K 200ΩPage 52Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.com21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300)
222I-Series Input Signal Conditioning Modules continuedIR03: Linear Potentiometer 1KΩ minDigital ScalingPOTENTIOMETERInputTIGERExcGndLEOPARD1KΩ Minimum1MΩ MaximumLYNX273AISD5: Smart DC Volts. 24 Bit. 50 Hz rejection.ISD6: Smart DC Volts. 24 Bit. 60 Hz rejection.ISD7: Smart DC Volts. 24 Bit. 50 Hz w/dual SSRs.ISD8: Smart DC Volts. 24 Bit. 60 Hz w/dual SSRs.TIGERHigh Resolution24 bit+2mV - 2VCH 1 -+2V - 60VCH 2 -EXCNormally Open SP 6Common SP 5, SP 6Normally Open SP 5PIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8SMART DC VSP 6SP 5SSRSSR264EISS1: Smart Pressure/Load Cell. 16 bit (50 Hz rejection)ISS2: Smart Pressure/Load Cell. 16 bit (60 Hz rejection)ISS3: Smart Pressure/Load Cell. 24 bit (50 Hz rejection)ISS4: Smart Pressure/Load Cell. 24 bit (60 Hz rejection)TIGERUp to eight 350Ω strain gagescan be connected in parallelSENSE -SENSE +EXCINPUT HIGHINPUT LOW- EXCGUARDNOT USEDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 86 W4 WSMART PRESSURE263FIS01: Strain Gage 5/10VDC Exc., 20/2mV/V, 4/6-wireIS02: Pressure/Load Cell5/10VDC Exc., 20/2mV/V, 4/6-wireTIGERLEOPARDPressure TransducerPRESSUREEXC20mV/V5V10V151AISD9: Smart Voltage and Resistance InputTIGEREXTERNAL mVTRANSDUCER(Voltage output)ResistanceMeasurementSIGNAL HIVOLT HISIGNAL LOW VOLT LOWSUPPLY VOLT EXCGROUND EXC RTNCURRENT EXCRESISTANCE HIRESISTANCE LOWCURRENT RTNPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8318BISS5: Dual Smart Pressure. 16 bit. Optimized for 50 Hz rejection.ISS6: Dual Smart Pressure. 16 bit. Optimized for 60 Hz rejection.TIGER SENSE -SENSE +EXCINPUT HIGH 1INPUT LO 1INPUT HIGH 2INPUT LO 2GNDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 86 W4 W304B4W6WIS03: Pressure/Load Cell with AutoCal5/10VDC Exc., 20/2mV/V, 4-wireTIGERPressure TransducerRCALAUTO CALPRESSURE WITH AUTOCALEXC20mV/V5V6W10V4W151BISDA: Smart Dual DC Volts. 16 bit. 50 Hz rejection.ISDB: Smart Dual DC Volts. 16 bit. 60 Hz rejection.TIGER1 to 20Samples / sec2mV - 2VCH 12V - 60VCH 2EXCNormally Open SP 6Common SP 5, SP 6Normally Open SP 5+-+-SMART DC V HIPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8303CISS7: Smart Quad Pressure/Load Cell. 16 bit. 50 HzISS8: Smart Quad Pressure/Load Cell. 16 bit. 60 HzTIGERIN HI 1IN LO 1IN HI 2IN LO 2IN HI 3IN LO 3IN HI 4IN LO 4+ SENSE- SENSE+ EXC- EXCGUARDNOT USEDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8PIN 9PIN 10PIN 11PIN 12PIN 13PIN 14PIN 15PIN 16357BIS04: Pressure/Load Cell Ext Exc., 20/2mV/V, 4/6–wireTIGERLEOPARDFor multiple pressure transducersExternalPowerSupply 5 V or 10 VmV/VEXC205V6W10V4W150AISL1: Smart Dual LVDT. 50 HzISL2: Smart Dual LVDT. 60 HzTIGERLVDT 1LVDT 2+ SIGNAL 1– SIGNAL 1– EXC 1+EXC 2+ SIGNAL 2– SIGNAL 2+24VCONTROL 1CONTROL 2GNDSHIELDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8PIN 9PIN 10PIN 11345AISS9: Smart Dual Input, LC and Process (4-20mA)TIGER SENSEPIN 1+ EXCPIN 2+ SENSEPIN 3INPUT HIGHPIN 4INPUT LOWPIN 5EXCPIN 6GUARDPIN 7mA HIPIN 8mA LOWPIN 94 - 20 mANOT USED PIN 100 - 10 VNOT USED PIN 116 W4 W361CIS05: Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wireISM1: Smart Magnetostrictive InputISSA: Smart Quad Potentiometer/ResistanceTIGERIS02LEOPAR<strong>DI</strong>S02LYNXPressure TransducerPRESSUREmV/Vor Load Cell 210V5VEXTEXC20RANGEHILO244CMagnetTIGERBalluffMicropulseTransducerAlarmLevel monitoring using a Balluff Micropulse transducer connected to the module. Setpoint (1) isconnected as an alarm output.PULSE +PIN 1PULSE —PIN 2INTERROGATE +PIN 3INTERROGATE —PIN 4+24 VPIN 5GROUNDPIN 6OC2PIN 7OC1PIN 8328D+ EXCWIPER 1TIGER EXCPIN 1+ EXCPIN 2WIPER 2PIN 3PIN 4EXCPIN 5X 4 LINEAR POTSPIN 6+ EXCPIN 7WIPER 3PIN 8EXCPIN 9+ EXCPIN 10WIPER 4PIN 11EXC372AIS06: Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wireTIGERIS04LEOPAR<strong>DI</strong>S04LYNXFor multiple pressure transducers– +5 V or 10 V External PowerSupply Drift is RatiometricallyCompensated by ModulePRESSURE10V5VEXTEXCmV/V220RANGEHILO244CISP1: Smart Triple Input, Pressure Direct andDual Counter (Frequency/Counter)TIGERABSOLUTE /<strong>DI</strong>FFERENTIALPRESSURECOUNTER 1COUNTER 2+24 V EXCDC - GND (-2.5V)PIN 1PIN 2PIN 3PIN 4317CISSB: Smart Dual Input, Load Cell and RTDTIGERSENSE -PIN 16 W+ EXCPIN 2+ SENSEPIN 3INPUT HIGHPIN 4INPUT LOW4 WPIN 5- EXCPIN 6GUARDPIN 7PIN 8PIN 9PT 100 RTD (CH1)PIN 10NOT USED PIN 11359BIS07: Pressure/Load Cell Ext Exc. High Impedance,20/2mV/V, 4/6–wireTIGERLEOPARDFor multiple pressure transducersExternalPowerSupply 5V or 10VPressure Hi ImpedanceZERO20mV/V6W4W25V10VExc277AISR1: Smart Single 3-Wire Potentiometer. 24 bit. 50 HzISR2: Smart Single 3-Wire Potentiometer. 24 bit. 60 HzTIGERLINEAR<strong>DI</strong>SPLACEMENTTRANSDUCER2.5 V EXC-OUTINCREASING SIGNAL WIPER 1EXC-LONOT USEDNOT USEDNOT USEDNOT USEDNOT USEDPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8308AISSC: Smart Triple Input, 16 bit, Load Cell and twoDigital Inputs (Frequency/Counter) (Optimized for 50 Hz)ISSD: Smart Triple Input, 16 bit, Load Cell and twoDigital Inputs (Frequency/Counter) (Optimized for 60 Hz)TIGER –SENSEPIN 1+ EXCPIN 2+ SENSEPIN 3INPUT HIGHPIN 4INPUT LOWPIN 5–EXCPIN 6GUARDPIN 7+ 24 V EXCPIN 8STATUS 1PIN 9STATUS 2PIN 10GNDPIN 116 W4 W368BISD1: Smart DC Volts. 16 bit. Optimized for 50 Hz rejection.ISD2: Smart DC Volts. 16 bit. Optimized for 60 Hz rejection.ISD3: Smart DC Volts. 16 bit. 50 Hz rejection w/dual SSRs.ISD4: Smart DC Volts. 16 bit. 60 Hz rejection w/dual SSRs.TIGERHigh Speed50 to 800Samples / sec2mV - 2VCH 12V - 60VCH 2EXCNormally Open SP 6Common SP 5, SP 6Normally Open SP 5+-+-SMART DC V HIPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8303CISR3: Smart Dual 3-Wire Potentiometer. 16 bit. 50 HzISR4: Smart Dual 3-Wire Potentiometer. 16 bit. 60 HzTIGER2.5 V EXC-OUTINCREASING SIGNAL WIPER 1EXC-LO2.5 V EXC-OUTINCREASING SIGNAL WIPER 2EXC-LOLINEARNOT USED<strong>DI</strong>SPLACEMENTNOT USEDTRANSDUCERSPIN 1PIN 2PIN 3PIN 4PIN 5PIN 6PIN 7PIN 8308AISSE: Smart Dual Photo Diode InputTIGER + DETECTOR 1PIN 1– DETECTOR 1PIN 2SHIELDPIN 3+ 5 VPIN 4– 5 VPIN 5+ DETECTOR 2PIN 6– DETECTOR 2PIN 7SHIELDPIN 8+ SOURCEPIN 9– SOURCEPIN 10SHIELD PIN 11339SSRSSR21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300) Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.comPage 53