11.07.2015 Views

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Setpoint Programming Mode continuedSetpoint & Relay Control Settings DiagramThe diagram below and continued on Page 43 shows the 1st, 2nd, and 3rd digit control settings for the setpoints and relays.Relay Energize Function0 Energized ABOVE setpoint value.1 Energized BELOW setpoint value.FIRST <strong>DI</strong>GIT SECOND <strong>DI</strong>GIT THIRD <strong>DI</strong>GIT2 Energized ABOVE setpoint value with FALLINGINPUT SIGNAL INITIAL START-UP INHIBIT.3 Energized BELOW setpoint value with RISINGINPUT SIGNAL INITIAL START-UP INHIBIT.SP Activation Source0 Activate Setpoint Source fromSelected Register1 Select Source for SetpointNote:[X1X] is a register selection procedureonly. To finish, reset to [X0X] to activatethe selection, or reset to 2-7 as requiredfor digital input selection.2 Digital Input – Capture Pin3 Digital Input – D14 Digital Input – D25 Digital Input – D36 HOLD Pin7 LOCK PinSP Delay & Timing Functions0 No Latching1 Relay Latched2 Manual Relay Reset3 Relay Latched with Manual RelayReset4 Relay Latched Off5 Hysteresis, Deviation & PID Mode6 Timer Modes:•Normal Delay.•Repeat ON.•Pulse ON.•1-Shot ON.•Repeat OFF.•Pulse OFF.•1-Shot OFF.See Set UpHysteresis,Deviation & PIDMode SettingsbelowSelect Source for Setpoint FunctionsNote:In PID mode, all Timer Modes onSP1 set in [XX6] are not functional.Go to Page 43[100][200][244][tArE]P[ 10][VALEY][ 1]Use the buttons tocycle through the RegistersMenu and Registers (1 to 244)to select data source for setpoints(also see page 44).[PEAK][diSP][tot_2][rESLt][tot_1][Ch1][Ch2][Ch3][Ch4]7 Advanced Functions Mode:•Reset Trigger.•Reset Destination.•Reset Mode.•Reset Constant.•Trigger Print from SP.•Trigger Log from SP.•Annunciator Flashing & SP Tracking.Note:[XX5], [XX6], and [XX7] are set upprocedure settings only. To finish,reset to 0-4 as required for setpointlatching and relay reset modes.Go to Page 43Set Up Hysteresis, Deviation & PID Mode SettingsProgramming TipIf you do not require anyof the functions in thismode, ensure it is set to:Third digitset to [XX5]XXNote:If PID is selected in [XX5],the Timer Delay [XX6] andReset and Trigger Functions[XX7] revert to [ModE][oFF]and cannot be adjusted.PPID FROM SETPOINT1 AND 2 ONLYP P PPPSet Hysteresis from 0 to 65535counts. Selected counts apply +and – from setpoint valueSet Deviation from 1 to 65535counts. Selected counts apply +and – from setpoint valueSet the Span Set the Proportional Band Value Set the Integral ValueMIN 0MAX 99999PSelect Flash Setting OFF or ONMIN 0%MAX 999.9%PSelect Tracking SettingMIN 0MAX 9999.9toPReset SPC_X to [XX0]XXOFF= Tracking Off1 = SPX tracks SP12 = SPX tracks SP23 = SPX tracks SP34 = SPX tracks SP45 = SPX tracks SP56 = SPX tracks SP6XXNote:The output from RELAY1 is disabled if minimumcycle time set to 0Set the Derivative Value Set the Anti-reset Wind-up % PB Set the Minimum Cycle TimeP P PMIN 0MIN 0.1%MIN 0 secsMAX 999.9MAX 100.0%MAX 1000.0 secsPage 42Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.com21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!