DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

DI-50E Data Sheet - K - Tech, Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SP1 SP2 SP3 SP4 SP5 SP6SP1 SP2 SP3 SP4 SP5 SP6Setpoint Programming ModeAll setpoint activation and control settings are selected and configured usingthe front panel buttons in the setpoint programming mode. Or, softwareconfigured via the meter configuration utility program if the meter is connectedto a PC through the serial port. The meter has six software driven setpoints,independently configured to operate within the total span range of themeter and the selected input module.Relay Output ModulesFive standard relay output module options provide a selection of 20 relayconfiguration options for <strong>DI</strong>-50 meters.Three electromechanical relay output modules support a combination of 5 AForm A and 10 A Form C relays providing 12 configuration options. A solidstate relay (SSR) output module supports 400 V, 210 mA DC SSRs andanother SSR output module supports 400 V, 140 mA AC / DC SSRs providinga further eight configuration options.A 22 opto-isolated I/O plug-in module can support six inputs and up to 16outputs. The standard plug-in module has six inputs and six outputs that canbe extended to 16 outputs with a 10 output add-on board.Prog.Operational DisplaySetpoint Programming ModeTo enter press P andbuttons at the same timeSetpoint Activation Values Mode[SP_1]P[SP_2]PEnter these menus to set setpoint (SP)activation valuesSetpoint 1 Default setting = 18000Setpoint 2Default setting = –18000320 Series Relay Output Module OptionsSSRsElectromechanical RelaysOutput ModuleCarrier Board[SP_3]P[SP_4]Setpoint 3Setpoint 4Default setting = 5000Default setting = –5000PMax Four140 mA(AC/DC)Max Four210 mA(DC Only)Max Four5 A Form AMax Two5 A Form AMax Two10 A Form CMax Six5 A Form A[SP_5]P[SP_6]Setpoint 5Setpoint 6Default setting = 10000Default setting = –10000Optional Opto-isolated22 I/O Plug-in ModuleDigital OutputsAdd-on Board(10 outputs)Mountson topStandard I/OPlug-in Module(6 in/6 out)PSetpoint & Relay Control Settings ModeEnter these menus to configure SPcontrol settingsSetpoint Programming ModeSee the Setpoint Programming Mode Logic Diagram opposite.The setpoint programming mode is entered by pressing the meter’sbuttons at the same time.Setpoint Activation ValuesEach setpoint activation value is individually programmed. Setpoint activationvalues can be set within the total span range of the meter and the selectedinput module.Setpoint and Relay Control SettingsSee the Setpoint and Relay Control Settings diagram on Pages 42 and 43.The control settings provide access to the following setpoint and relay functionsfor configuration using the meter’s 1st, 2nd, and 3rd digits:• 1st Digit – Relay Energize Functions.• 2nd Digit – Setpoint Activation Source.• 3rd Digit – Setpoint Delay, Timer, and Reset and Trigger Functions.Pand[SPC_1]P[SPC_2]P[SPC_3]P[SPC_4]P[SPC_5]P[SPC_6]POperational DisplaySetpoint 1Setpoint 2Setpoint 3Setpoint 4Setpoint 5Setpoint 6See Page 42 fora Level 1 –Setpoint & RelayControl Settingsdiagram.Prog.Setpoint Mode Logic DiagramPage 38Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.com21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!