[CAL] - Calibration Modes for Input and Output continuedTwo-point CalibrationTwo-point calibration is the most commonly used method of calibratingTiger 320 Series meters when a low and high inputsource is available.Example Calibration ProcedureCalibrate channel 1 (CH1) using the two-point calibrationmethod. Set the calibration mode display to [111].The low input source is applied tothe meter when setting the zerovalue.The high input source is appliedto the meter when setting thespan value.LOWSignalHIGHSignalProg.Prog. SP1 SP2 SP3 SP4 SP5 SP6SP1 SP2 SP3 SP4 SP5 SP6STARART T HERETWO POINTCALIBRATIONOperational DisplayProg. SP1 SP2 SP3 SP4 SP5 SP6Pressat sametimeFrom Step 6Step 1Enter Brightness ModeStep 2Pass Brightness Modeand enterCalibration ModePressat sametimePress1Prog. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6HIGHStep 7 Signal7.1. Adjust display todesired reading forspan input7.2. Apply the HIGHinput signalStep 8Save zero and spansettings and re-enterCalibration ModePress1Prog. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6ORExampleStep 3Set Calibration Mode to [111]:1st Digit = 1Selects calibration procedures2nd Digit = 1Selects 2-point calibration3rd Digit = 1Selects CH1 for calibrationProg. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6ORStep 9Select the No FunctionCalibration Mode [000]XProg. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6ORStep 4Enter Cal Mode [111]For 2-point calibrationof CH1Press1Prog. SP1 SP2 SP3 SP4 SP5 SP6Step 10Save Calibration Mode[000] setting andenter Code 1Press1Prog. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6Step 55.1. Adjust display todesired reading forzero input5.2. Apply the LOWinput signalLOWSignalProg. SP1 SP2 SP3 SP4 SP5 SP6ORStep 11Exit code 1 and returnto operational displayPressat sametimeProg. SP1 SP2 SP3 SP4 SP5 SP6Prog. SP1 SP2 SP3 SP4 SP5 SP6Pressat sametimeStep 6Set reading for zeroload into meter andenter Span ModePress1Prog. SP1 SP2 SP3 SP4 SP5 SP6To Step 7ExampleProg. SP1 SP2 SP3 SP4 SP5 SP6Operational Display21 June, 2004 <strong>DI</strong>-50 320 Series (NZ300) Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.comPage 23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!