Front Panel Programming CodesThe meter’s manual programming codes are divided into twomodes: the main programming mode, and the setpoint programmingmode (See diagram below).Each mode is accessible from the operational display.Main Programming ModeThe main programming mode provides access to program allmeter functions, except setpoints.Operational DisplayProgramming TipThe easiest and fastest way to configure theTiger 320 is to use a PC with the free downloadableconfiguration utility program. (see page 10)Setpoint Programming ModeThe setpoint programming mode provides access to programall setpoint and relay functions.To enter or exit the MainProgramming Mode, pressP and at the same timeMain Programming ModeProg.SP1 SP2 SP3 SP4 SP5 SP6To enter or exit the SetpointProgramming Mode, press P andat the same timeSetpoint Programming Mode[bri]P[CAL]P[Cod_1]P[Cod_2]P[Cod_3]P[Cod_4]P[Cod_5]P[Cod_6]P[Cod_7]P[Cod_8]P[Cod_9]Display BrightnessCalibration Modes for Input and OutputCode 1 – Display ConfigurationCode 2 – CH1 Measurement Task & Sampling RateCode 3 – CH1 Post Processing & Serial Mode FunctionsCode 4 – CH2 Measurement Task & Sampling RateCode 5 – CH3 FunctionsCode 6 – CH4 FunctionsCode 7 – Result ProcessingCode 8 – <strong>Data</strong> Logging & Print ModeCode 9 – Functions for Digital Input PinsProgramming TipSave Code Settings & ExitTo save a new main programmingmode configurationsetting and return tothe operational display atany point, press the Pbutton once.Then press the P andbutton at the same time toexit.Programming TipSave SP Settings & ExitTo save a new setpointconfiguration setting andreturn to the operationaldisplay at any point,press the P buttononce.Then press the P andbutton at the sametime to exit.Setpoint Activation ValuesEnter these menus to adjustSP activation values[SP_1]P[SP_2]P[SP_3]P[SP_4]P[SP_5]P[SP_6][SPC_1]Setpoint 1Setpoint 2Setpoint 3Setpoint 4Setpoint 5Setpoint 6Setpoint & Relay Control Function SettingsPEnter these menus to configureSP control values[SPC_2]P[SPC_3]P[SPC_4]P[SPC_5]PSetpoint 1Setpoint 2Setpoint 3Setpoint 4Setpoint 5The Setpoint andRelay ControlSettings diagramon Pages 42 and43 shows thethree digit configurationsettingsthat are appliedindividually toeach setpoint.See Page 41 for anexample procedureto configure asetpoint for simplerelay functions.P[SPC_6]Setpoint 6[Cod10]PCode 10 – Bargraph SetupCode 10 applies to Tiger 320 Series meters with bargraph displaysonly. See user manuals for <strong>DI</strong>-50B51, FI-B101D50, andGI-50B101.POperational DisplayProg.SP1 SP2 SP3 SP4 SP5 SP621 June, 2004 <strong>DI</strong>-50 320 Series (NZ300) Texmate, <strong>Inc</strong>. Tel. (760) 598-9899 • www.texmate.comPage 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!