11.07.2015 Views

LMR PLUS Electric Fire Pump Controllers Features

LMR PLUS Electric Fire Pump Controllers Features

LMR PLUS Electric Fire Pump Controllers Features

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>LMR</strong> <strong>PLUS</strong> <strong>Electric</strong> <strong>Fire</strong> <strong>Pump</strong> <strong>Controllers</strong><strong>Features</strong>1-1<strong>LMR</strong><strong>PLUS</strong>FD30 Full Voltage - Across the Line June 2010Power I/O BoardTransformersIncoming line voltage is run directly to the I/Oboard from the incoming lines. The I/O boardwill accept voltage inputs between 100 and600V.Membrane KeypadDoor MountThe membrane keypad mounts on the inside ofthe front door of the controller. Access forprogramming is provided through a panelcutout.Customer Connection TerminalsConnection terminals for external customerconnections, are located at the top of the PowerI/O board.Product DescriptionThe FD30 controller operates Across-The-Linewhere full voltage is applied to the motor forstarting by the use of a single motor contactor.Starting inrush current is approximately 600% ofrated full load amperes. The FD30 can beprogrammed for either fully automatic or semiautomaticoperation.The use of an embedded web page forretrieving diagnostics and history reports, alongwith USB and Ethernet communication ports fordownloading data, make the <strong>LMR</strong> Plus Series ofcontrollers easy to troubleshoot and maintain.As well, critical information can be easilyaccessed and used for report generation andanalysis, which aids in providing effective,reliable fire protection.Product <strong>Features</strong>Logic Controller BoardCommunicationThe controller has the ability to display andoutput current values and status, on command,from various software protocols through theappropriate port(s).Embedded Web PageThe web page is a multifunction tool that allowsthe user to view the controller’s current status,data values, programmed set points and history.USB Port / USB DriveThe logic controller board is equipped with aUSB port that can be used to transfer data toand from a portable USB Drive device (memorystick).Ethernet PortThe on-board Ethernet port is used for directconnection to a computer for data transfer.RS485 Serial PortAn RS485 serial port is provided forcommunication to various external softwareprograms.BuzzerA buzzer is mounted on the logic board whichwill operate if Fail to Start, HardwareMalfunction or any Common Alarm conditionexists.Output RelaysSeven socket mount, 8 Amp, 2 Form - C(DPDT) output relays are provided standard oneach power I/O board. They are designated for:Common Alarm, Phase Failure, PhaseReversal, <strong>Pump</strong> Run, Startup, Acceleration andFuture # 1. Each socket has an LED mountedon the I/O board which indicates each relay’scoil status.Optional Output Relay BoardsThere is provision to add up to eight additionalrelay outputs, via optional relay output boards.Each board contains a maximum of 2 additionalrelays. The Power I/O Board will accept amaximum of 4 optional boards which mount in asnap-on configuration.Each board provides an area for the user tolabel the terminal number and relay name.Drain Valve SolenoidAll <strong>LMR</strong> Plus electric controllers are equippedwith a drain valve solenoid used for weekly testpurposes.USB External DriveGeneralWhen using an external USB Drive, the driveshould conform to the following specifications:Min: 128mbMax: 2 Gig FAT16 protocolUSB 1.0 or 2.0NEMA 2 EnclosuresAll <strong>LMR</strong> controllers come standard with NEMA 2enclosures unless otherwise ordered. Availableoptions include: NEMA 3R, 4, 4X, 12.Emergency Start OperatorA mechanically operatedemergency start handleactivates the motorcontactor independent ofany electrical controlcircuits or pressureswitch input.NEMA RatingThe standard membrane keypad is rated forNEMA 2, 3R, 4, 4X and 12.Alarm & Status LED’sA total of 20, ( 10 Status - 10 Alarm ) LED’sprovide indication on the membrane keypad.Status LED’sPower On<strong>Pump</strong> RunningLocal StartRemote StartDeluge ValveEmergency StartInterlock OnLow PressureAuto Shutdown EnabledProgrammable LED # 1Alarm LED’sPhase ReversalPhase FailureFail To StartUndervoltageOvervoltageLow Room TemperatureLocked Rotor TripLow Suction PressureSource 2 DisconnectedProgrammable LED # 2Silence ButtonA silence pushbutton on the membrane can beused to silence the buzzer. When an alarmcondition exists, the alarm buzzer will sound. Ifthe Silence Alarm button is pressed, the alarmbuzzer will turn off. If a subsequent alarmcondition occurs after the silence button ispressed, the buzzer will re-sound. Pressing theSilence Alarm button again, will silence thebuzzer.Motor Test ButtonThe motor test button on the membrane can beused to simulate an automatic start.Automatic Shutdown EnabledWhen the Automatic Shutdown function isenabled, a Green LED will indicate on thecontroller membrane.Standards & CertificationThe <strong>LMR</strong> Plus <strong>Electric</strong> <strong>Fire</strong> <strong>Pump</strong> <strong>Controllers</strong>meet or exceed the requirements ofUnderwriters Laboratories, UnderwritersLaboratories Canada, Factory Mutual, theCanadian Standards Association, New York Citybuilding code, CE mark requirements and arebuilt to NFPA 20 standards.N. Y. C.APPROVEDFor more information visit: www.chfire.comBR05805047K/F


<strong>LMR</strong> <strong>PLUS</strong> <strong>Electric</strong> <strong>Fire</strong> <strong>Pump</strong> <strong>Controllers</strong><strong>Features</strong>1-2FD30 Full Voltage - Across the Line June 2010Product <strong>Features</strong>Main DisplayGeneralThe main display will show the current systempressure, time and date, voltage and ampsreading for all three phases, the systemfrequency and any custom messages, alarmsor timers.Programmed Set-PointThe set-point display will show programmedpressure start point, pressure stop point andweekly test timer setting.StatisticsThe statistics display will allow the user toscroll through all of the measured statisticsstored in memory. Refer to <strong>LMR</strong> Plus operationmanual IM05805020K for specific details.DiagnosticsThe diagnostics display allows the user toscroll through various diagnostic points toassist with troubleshooting the system.Message HistoryThe user will be able to scroll through all of themessages stored in the memory of thecontroller with the most recent message beingdisplayed first.PRINT MenuDescriptionAll fault and alarm information is sent to theUSB and Printer ports on demand, as well asthe status of each output. The <strong>LMR</strong> Plus willstore up to 10K events which are time and datestamped. All information can also be retrievedand displayed on the LCD display.Saving to USB DriveThe controller will save four separate text files,one CSV file and the embedded webpage to theUSB external drive. The files, at maximum size,can be saved multiple times on one 128MBUSB drive.Files to be saved are: Status Report,Diagnostics Report, Statistics Report,Configuration File and Last 5K Messages.Print MenuThe printer menu is accessed in order to selectthe desired print function.Functions include: Print Messages, Last XXMessages, Date & Time, Status Report,Diagnostics Report and Statistics Report.Custom MessagesWhen this item is selected, custom messagescan be cleared from memory or downloadedfrom the USB external drive.Firmware UpdateFirmware revisions are updated from anexternal USB drive. All previously programmedsettings will remain intact when updating iscompleted. Should there be an update failure,the controller will automatically revert back tothe previous version of firmware.Embedded WebpageGeneralThe embedded webpage is a multifunction toolthat will allow the user to view the current statusof the controller as well as display all currentreadings, set points,and history. An externalcomputer can beconnected via theEthernet port toaccess the page.When connected,the controller setpoints can beprogrammedvia the webpage.Multiple PagesThere are 5 viewable pages that show the MainDisplay, Statistics, Diagnostics, History andProgrammed Set Points.Pressure PointsThe pressure reports recorded in memory canbe graphed and/or sorted based on date andtime.Programmed Set PointsAll of the programmed set points and theircurrent status can be viewed via the webpage.Custom MessagesUsers can create custom messages on acomputer and upload to the controller using aUSB Drive (memory stick). Up to 10 custommessages of up to 100 characters each, willcontinuously scroll across the fourth line of theLCD display once uploaded.Trigger PointsThe message can be programmed to appear atspecific trigger points such as specific date andtime, specific number of operations, specificnumber of hours run or at any individual alarmpoint.All of the trigger points can be selected asAnd/Or values.Programming MenuGeneralThe <strong>LMR</strong> Plus programming menu is dividedinto 8 different sub-menus. Each sub-menucontains information relative to it’s particularfunction. Following is a brief description of eachsub-menu.LanguageThe language sub-menu allows the user to selectEnglish, French, Spanish or Other languages tobe viewed on the LCD Display. Several otherlanguages can be uploaded into the controller.Contact the factory for details.RegionalRegional settings include the ability to programthe date by adjusting the Month, Day, Year andDay of Week. As well, the Current Time can beadjusted on the 24 hour clock.PressureA variety of pressure settings can beprogrammed in the pressure sub-menu. Thesesettings include disabling the pressuretransmitter; setting of the start point, stop point,low pressure alarm, high pressure alarm, stopmode, proof pressure switch (for foam units), lowsuction shutdown (low foam interlock), pressuredeviation and hourly pressure recording. Refer tothe <strong>LMR</strong> Plus operation manual IM05805020Kfor details.TimersTimers in the <strong>LMR</strong> Plus that can be programmedinclude: Run Period Timer (RPT), RPT StartMode, Acceleration Timer (AT), Weekly TestTimer, Fail to Start Timer (FST) and SequentialStart Timer (SST). Refer to the <strong>LMR</strong> Plusoperation manual IM05805020K for details.Alarm Set PointsThere are five settable alarm points that can beprogrammed by the user. They include: PhaseRotation, Over Voltage (OV), Under Voltage(UV), Over Frequency (OF) and UnderFrequency (UF). Refer to the <strong>LMR</strong> Plus operationmanual IM05805020K for details.Custom Inputs / OutputsThere is provision on the Power I/O Board toaccept up to 9 additional inputs and 9 additionaloutputs. Each of the inputs can be labeled usingone of 11 pre-set input descriptions or assigned acustom description that is programmed by theuser. The optional outputs can be programmed toindicate up to 25 output conditions. As well, twooptional alarm LED’s can be programmed for upto 12 alarm conditions.All optional inputs, outputs and LED’s can belinked, as required.Inputs can be programmed to energize thecommon alarm output, link to relays and optionalLED’s and latch until reset by the user.Outputs can be programmed for fail safe andlatch until reset by the user.Optional inputs and outputs can be programmedwith time delay functions.System Configuration MenuThe system configuration menu section ispassword protected and contains settings suchas system voltage, frequency, CT ratio etc. Referto Technical Bulletin PU05805035K/Dfor details.Main Menu PasswordA password can be programmed by the user toprotect access to the Main Menu. Refer to the<strong>LMR</strong> Plus Operation Manual IM05805020K fordetails.BR05805047K/FFor more information visit: www.chfire.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!