SymbolABCDEFGContentGas piping12.712"FlareLiquid piping6.3514"FlareHole on wall for right rear piping 65Hole on wall for left rear piping 65Drain hoseVP16Screw point fasten the indoor unit 5Outlet for pipingon both side108401076.3 157.285.3 22.7585544.8 20F83.5 620 156.530.5 726103.5138.5255255211.535Installation plateUnitFAB5.2585514.8 80Service space70Model SRF50ZJX-S119855100 601854545156.2203F30.5F804 25.5Service space 50 6565482.8DEC50+Service space860238Space for installation and service when viewing from the frontWireless remote controllerWired remote controllerOption150TermRFB000Z005Outlet for down pipingRefer to the above view60060126G15 60100125- 73 - '11 • SCM-DB-1096017.3120 19Notes1The model name label is attached on the rightside of the unit.2It takes the interface kit SC-BIKN-Eto connect the wired remote controller.3In case of wall installation, leave the unit 150mm or less from the floor.Unit:mm
19015(Suspension bolts pitch)51552 148 3041 170 19160 40174.430.311 13(3) Ceiling concealed type (SRR)3030Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S325.435 670 (Suspension bolts pitch)3510 24105100220D740 105.790 220 105540FIG.A☆ ☆ ☆ ☆ ☆168 168 168 16810015 7101518.5In case of filter guide taken off703In case of filter guide installed(normal condition)FIG.A(Air inlet from lower)241018.5Control BoxE25311.2230304558-φ2.8Holes for tapping screws(φ4)'11 • SCM-DB-109SymbolContentModelSRR25ZJ-S, SRR50ZJ-S,35ZJ-S60ZJ-SA Gas pipingφ9.52(3/8") φ12.7(1/2")(Flare) (Flare)B Liquid pipingφ6.35(1/4")(Flare)C Drain pipingVP16D Suspension bolts(M8)E Power supply intake (φ35)Wireless remote controllerWired remote controller(Option)6017.3□120 19Terminal blockAir outletBNote(1)The model name label is attachedon the lid of the control box.(2)It takes the interface kit (SC-BIKN-E)FIG.Bto connect the wired remote controller.CAir inletAUnit:mm135 38236 7515 71015168 168 168 16810 2424 102369423In case of rear panel taken off82 574 84404035 67035In case of filter guide installed(option)FIG.B(Air inlet from rear)RJD000Z502 A15011-φ2.8Holes for tapping screws(φ4)5-φ3.3(☆ Mark only)Holes for tapping screws(φ4)9-φ2.8Holes for tapping screws(φ4)6-M4For hanger plate1501502012020 80 80 403217721203.711.3
- Page 23 and 24: 1.4. Noise levels'11 • SCM-DB-109
- Page 25 and 26: ModelNoiseLevelModelNoiseLevelSound
- Page 27 and 28: '11 • SCM-DB-1091.5. Installation
- Page 30 and 31: lethatof ailarlue.'11 • SCM-DB-10
- Page 32: 6CNEREDunits.readblesition.rm.nnoti
- Page 35 and 36: '11 • SCM-DB-109(3) Models SCM71Z
- Page 37 and 38: φφφφ'11 • SCM-DB-109
- Page 39 and 40: '11 • SCM-DB-109(4) Models SCM100
- Page 43 and 44: 2. INDOOR UNITS2.1 Specifications(1
- Page 45 and 46: ItemModelCooling capacity (1) W 350
- Page 47 and 48: ItemModelCooling capacity (1) W 600
- Page 49 and 50: ItemModelCooling capacity (1) W 350
- Page 51 and 52: ItemModelCooling capacity (1) W 250
- Page 53 and 54: ItemModelCooling capacity (1) W 500
- Page 55 and 56: Item(2) Floor standing type (SRF)Mo
- Page 57 and 58: ItemModelCooling capacity (1) W 500
- Page 59: ItemModelCooling capacity (1) W 350
- Page 62 and 63: ItemPower source(4) Ceiling cassett
- Page 64 and 65: ItemPower sourceModel'11 • SCM-DB
- Page 66 and 67: ItemPower sourceModel'11 • SCM-DB
- Page 68 and 69: 61.546.5Service space881.926 59.959
- Page 70 and 71: 4514.560790798603145294SymbolConten
- Page 72 and 73: 554191090109864443.555248SymbolABCD
- Page 76 and 77: 530 Suspension bolts pitchG326350AB
- Page 78 and 79: '11 • SCM-DB-109(6) Duct connecte
- Page 80 and 81: '11 • SCM-DB-109(b) Wired remote
- Page 82 and 83: DISPLAY12WIRELESS RECEIVERBACK-UP S
- Page 84 and 85: DISPLAYWIRELESS RECEIVERBACK-UP SWT
- Page 86 and 87: DISPLAYWIRELESS RECEIVER 10BACK-UP
- Page 88 and 89: PJA003Z340 BCNBZDMF200203FM IFSLED2
- Page 90 and 91: Connecting line betweenindoor unit
- Page 92 and 93: ModelNoiseLevelModelNoiseLevelSound
- Page 94 and 95: '11 • SCM-DB-109ModelSRK35ZJR-SNo
- Page 96 and 97: '11 • SCM-DB-109ModelSRK50ZJ-SNoi
- Page 98 and 99: '11 • SCM-DB-109ModelSRK50ZJX-S1N
- Page 100 and 101: '11 • SCM-DB-109ModelSRR60ZJ-SNoi
- Page 102 and 103: ModelNoiseLevelModelNoiseLevelSound
- Page 104 and 105: 2.5 Characteristics of fan'11 • S
- Page 106 and 107: BEFORE INSTALLATION Before installa
- Page 109 and 110: (b) Models SRK25ZJR-S, 35ZJR-SWALL
- Page 111 and 112: RLA012A012BFixing of indoor unitLat
- Page 113 and 114: (c) Model SRK71ZK-SRKW012A400AWALL
- Page 115 and 116: RKW012A400AFixing of indoor unitLat
- Page 117 and 118: (2) Floor standing type (SRF)Models
- Page 119 and 120: Fixing of indoor unitFloor installa
- Page 121 and 122: (3) Ceiling concealod type (SRR)Mod
- Page 123 and 124: Plan45551530Hanging b30 230150236Dr
19015(Suspension bolts pitch)51552 148 3041 170 19160 40174.430.311 13(3) Ceiling concealed type (SRR)3030Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S325.435 670 (Suspension bolts pitch)3510 24105100220D740 105.790 220 105540FIG.A☆ ☆ ☆ ☆ ☆168 168 168 16810015 7101518.5In case of filter guide taken off703In case of filter guide installed(normal condition)FIG.A(Air inlet from lower)241018.5Control BoxE25311.2230304558-φ2.8Holes for tapping screws(φ4)'11 • SCM-DB-109SymbolContentModelSRR25ZJ-S, SRR50ZJ-S,35ZJ-S60ZJ-SA Gas pipingφ9.52(3/8") φ12.7(1/2")(Flare) (Flare)B Liquid pipingφ6.35(1/4")(Flare)C Drain pipingVP16D Suspension bolts(M8)E Power supply intake (φ35)Wireless remote controllerWired remote controller(Option)6017.3□120 19Terminal blockAir outletBNote(1)The model name label is attachedon the lid of the control box.(2)It takes the interface kit (SC-BIKN-E)FIG.Bto connect the wired remote controller.CAir inletAUnit:mm135 38236 7515 71015168 168 168 16810 2424 102369423In case of rear panel taken off82 574 84404035 67035In case of filter guide installed(option)FIG.B(Air inlet from rear)RJD000Z502 A15011-φ2.8Holes for tapping screws(φ4)5-φ3.3(☆ Mark only)Holes for tapping screws(φ4)9-φ2.8Holes for tapping screws(φ4)6-M4For hanger plate1501502012020 80 80 403217721203.711.3