ItemPower source(4) Ceiling cassette -4way compact type (FDTC)'11 • SCM-DB-109Adapted to RoHS directiveModelFDTC25VDPanel TC-PSA-25W-E220/230/240V~50HzdB(A)Cooling P-Hi : 38 Hi : 36 Me : 32 Lo : 29Heating P-Hi : 39 Hi : 38 Me : 33 Lo : 29.5mmUnit 248 × 570 × 570Panel 35 × 700 × 700Plaster White(6.8Y8.9/0.2) near equivalentLouver fin & inner grooved tubingTurbo fan × 1CMMCooling P-Hi : 10 Hi : 9 Me : 8 Lo : 6.5Heating P-Hi : 10.5 Hi : 9.5 Me : 8.5 Lo : 7Not possiblePocket plastic net × 1 (Washable)Rubber sleeve (for fan motor)Polyurethane formwired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)Thermostat by electronicsOverload protection for fan motorFrost protection thermostatmmLiquid line : φ6.35 (1/4")Gas line : φ9.52 (3/8")Flare pipingBuilt-in Drain pumpHose Connectable with VP20Necessary (both Liquid & Gas lines)Mounting kit, Drain hoseItem Indoor air temperature Outdoor air temperatureOperation DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚CHeating 20˚C 7˚C 6˚CRWA000Z234 AOperation data Cooling HeatingNominal capacity kW 2.5 3.4Sound Pressure LevelExterior dimensionsHeight x Width x DepthExterior appearance(Munsell color)Net weight kg UNIT 15 PANEL 3.5Heat exchangerAir handling equipmentFan type & Q'tyMotor W 33 < Direct line start >Air flow (Standard)Available static pressure Pa 0Outdoor air intakeAir filter, Q'tyShock & vibration absorberInsulation (noise & heat)Remote controllerRoom temperature controlSafety equipmentInstallation dataRefrigerant piping sizeConnecting methodDrain pumpDrainInsulation for pipingStandard AccessoriesNotes (1) The data are measured at the following conditions when the air flow is high mode.(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound pressure level indicates the value in an anechoic chamber. During operationthese value are somewhat higher due to ambient temperature.(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.(5) When wireless remote controller is used, fan is 3 speed setting(Hi-Me-Lo) only.

ItemPower sourceModel'11 • SCM-DB-109Adapted to RoHS directiveFDTC35VDPanel TC-PSA-25W-E220/230/240V~50HzCooling P-Hi : 41 Hi : 40 Me : 36 Lo : 30Heating P-Hi : 43 Hi : 42 Me : 35 Lo : 32Unit 248 × 570 × 570Panel 35 × 700 × 700Plaster White(6.8Y8.9/0.2) near equivalentLouver fin & inner grooved tubingTurbo fan × 1Cooling P-Hi : 11 Hi : 9.5 Me : 9 Lo : 7Heating P-Hi : 11.5 Hi : 10.0 Me : 9 Lo : 8Not possiblePocket plastic net × 1 (Washable)Rubber sleeve (for fan motor)Polyurethane formThermostat by electronicsOverload protection for fan motorFrost protection thermostatLiquid line : φ6.35 (1/4")Gas line : φ9.52 (3/8")Flare pipingBuilt-in Drain pumpHose Connectable with VP20Necessary (both Liquid & Gas lines)Mounting kit, Drain hoseRWA000Z234 A- 62 -Operation data Cooling HeatingNominal capacity kW 3.5 4.5Sound Pressure LevelExterior dimensionsHeight x Width x DepthExterior appearance(Munsell color)dB(A)mmNet weight kg UNIT 15 PANEL 3.5Heat exchangerAir handling equipmentFan type & Q'tyMotor W 33 < Direct line start >Air flow (Standard)CMMAvailable static pressure Pa 0Outdoor air intakeAir filter, Q'tyShock & vibration absorberInsulation (noise & heat)Remote controllerRoom temperature controlSafety equipmentInstallation dataRefrigerant piping sizeConnecting methodDrain pumpDrainInsulation for pipingStandard Accessoriesmmwired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)Notes (1) The data are measured at the following conditions when the air flow is high mode.Item Indoor air temperature Outdoor air temperatureOperation DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚CHeating 20˚C 7˚C 6˚C(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound pressure level indicates the value in an anechoic chamber. During operationthese value are somewhat higher due to ambient temperature.(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.(5) When wireless remote controller is used, fan is 3 speed setting(Hi-Me-Lo) only.

ItemPower source(4) Ceiling cassette -4way compact type (FDTC)'11 • SCM-DB-109Adapted to RoHS directiveModelFDTC25VDPanel TC-PSA-25W-E220/230/240V~50HzdB(A)Cooling P-Hi : 38 Hi : 36 Me : 32 Lo : 29Heating P-Hi : 39 Hi : 38 Me : 33 Lo : 29.5mmUnit 248 × 570 × 570Panel 35 × 700 × 700Plaster White(6.8Y8.9/0.2) near equivalentLouver fin & inner grooved tubingTurbo fan × 1CMMCooling P-Hi : 10 Hi : 9 Me : 8 Lo : 6.5Heating P-Hi : 10.5 Hi : 9.5 Me : 8.5 Lo : 7Not possiblePocket plastic net × 1 (Washable)Rubber sleeve (for fan motor)Polyurethane formwired : RC-E4 (option) wireless : RCN-TC-24W-ER (option)Thermostat by electronicsOverload protection for fan motorFrost protection thermostatmmLiquid line : φ6.35 (1/4")Gas line : φ9.52 (3/8")Flare pipingBuilt-in Drain pumpHose Connectable with VP20Necessary (both Liquid & Gas lines)Mounting kit, Drain hoseItem Indoor air temperature Outdoor air temperatureOperation DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚CHeating 20˚C 7˚C 6˚CRWA000Z234 AOperation data Cooling HeatingNominal capacity kW 2.5 3.4Sound Pressure LevelExterior dimensionsHeight x Width x DepthExterior appearance(Munsell color)Net weight kg UNIT 15 PANEL 3.5Heat exchangerAir handling equipmentFan type & Q'tyMotor W 33 < Direct line start >Air flow (Standard)Available static pressure Pa 0Outdoor air intakeAir filter, Q'tyShock & vibration absorberInsulation (noise & heat)Remote controllerRoom temperature controlSafety equipmentInstallation dataRefrigerant piping sizeConnecting methodDrain pumpDrainInsulation for pipingStandard AccessoriesNotes (1) The data are measured at the following conditions when the air flow is high mode.(2) This packaged air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound pressure level indicates the value in an anechoic chamber. During operationthese value are somewhat higher due to ambient temperature.(4) The operation data indicates when the air-conditioner is operated at 220/230/240V 50Hz.(5) When wireless remote controller is used, fan is 3 speed setting(Hi-Me-Lo) only.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!