ItemModelCooling capacity (1) W 2500Heating capacity (1) W 3400Power supplyNoise levelCoolingHeating'11 • SCM-DB-109Adapted to RoHS directiveSRK25ZJX-S1 Phase, 220~240 V, 50HzFine snow(8.0Y 9.3/0.1) near equivalentLouver fins & inner grooved tubingMicrocomputer controlHi: 12.5 Me: 9.0 Lo: 5.0Not possibleWireless-Remote controlMicrocomputer thermostatRUN: Green, TIMER: Yellow, HI POWER: Green,3D AUTO: Green, ECONO: BlueFlare connectingLiquid line : 0.55Gas Line : 0.49Necessary (Both sides), independent1.5mm 2 x 4 cores (Including earth cable)Terminal block (Screw fixing type)Interface kit (SC-BIKN-E)The pipe length is 7.5m.StandardsISO-T1, JIS C 9612RWA000Z229 B- 43 -Sound level dB(A) Hi: 41 Me: 31 Lo: 22Power level dB 55Sound level dB(A) Hi: 41 Me: 34 Lo: 27Power level dB 58Exterior dimensions (Height x Width x Depth) mm 309 x 890 x 220Exterior appearance(Munsell color)Net weight kg 15RefrigerantequipmentAir handlingequipmentOperationcontrolSafety devicesInstallationdataHeat exchangerDevice controlFan type & Q'ty Tangential fan x 1Motor W 27Air flow Cooling CMMHeating Hi: 13.0 Me: 10.0 Lo: 7.5Fresh air intakeAir filter, Quality / Quantity Polypropylene net (washable) x 2Operation switchRoom temperature controlOperation DisplayFrost protection, Serial signal error protection, Indoor fan motor error protectionRefrigerant piping size (O.D) mm Liquid line:φ6.35 (1/4") Gas line:φ9.52 (3/8")Connecting methodAttached length of pipingInsulation for pipingmDrain hose Connectable (VP 16)Connection wiringSize x Core numberConnecting methodAccessories (included) Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)Optional partsNote (1) The data are measured at the following conditions.OperationItemIndoor air temperatureOutdoor air temperatureDB WB DB WBCooling 27˚C 19˚C 35˚C 24˚CHeating 20˚C — 7˚C 6˚C(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) The operation data are applied to the 220/230/240V districts respectively.
ItemModelCooling capacity (1) W 3500Heating capacity (1) W 4500Power supplyNoise levelCoolingHeating'11 • SCM-DB-109Adapted to RoHS directiveSRK35ZJX-S1 Phase, 220~240 V, 50HzFine snow(8.0Y 9.3/0.1) near equivalentLouver fins & inner grooved tubingMicrocomputer controlHi: 13.5 Me: 9.5 Lo: 5.0Not possibleWireless-Remote controlMicrocomputer thermostatRUN: Green, TIMER: Yellow, HI POWER: Green,3D AUTO: Green, ECONO: BlueFlare connectingLiquid line : 0.55Gas Line : 0.49Necessary (Both sides), independent1.5mm 2 x 4 cores (Including earth cable)Terminal block (Screw fixing type)Interface kit (SC-BIKN-E)The pipe length is 7.5m.StandardsISO-T1, JIS C 9612RWA000Z229 B- 44 -Sound level dB(A) Hi: 43 Me: 33 Lo: 22Power level dB 58Sound level dB(A) Hi: 42 Me: 35 Lo: 27Power level dB 59Exterior dimensions (Height x Width x Depth) mm 309 x 890 x 220Exterior appearance(Munsell color)Net weight kg 15RefrigerantequipmentAir handlingequipmentOperationcontrolSafety devicesInstallationdataHeat exchangerDevice controlFan type & Q'ty Tangential fan x 1Motor W 27Air flow Cooling CMMHeating Hi: 14.0 Me: 11.0 Lo: 8.0Fresh air intakeAir filter, Quality / Quantity Polypropylene net (washable) x 2Operation switchRoom temperature controlOperation DisplayFrost protection, Serial signal error protection, Indoor fan motor error protectionRefrigerant piping size (O.D) mm Liquid line:φ6.35 (1/4") Gas line:φ9.52 (3/8")Connecting methodAttached length of pipingInsulation for pipingmDrain hose Connectable (VP 16)Connection wiringSize x Core numberConnecting methodAccessories (included) Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)Optional partsNote (1) The data are measured at the following conditions.OperationItemIndoor air temperatureOutdoor air temperatureDB WB DB WBCooling 27˚C 19˚C 35˚C 24˚CHeating 20˚C — 7˚C 6˚C(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) The operation data are applied to the 220/230/240V districts respectively.
- Page 1 and 2: Manual No.'11•SCM-DB-109updated S
- Page 3: 2.4 Noise levels ..................
- Page 7 and 8: '11 • SCM-DB-109ModelItemSCM50ZJ-
- Page 9 and 10: '11 • SCM-DB-109ModelItemSCM71ZJ-
- Page 13 and 14: SymbolContentA Service valve connec
- Page 15: SymbolContentA Service valve connec
- Page 19 and 20: tttt- 18 -RWC000Z252FUSE250V 15ATB1
- Page 21 and 22: t°t°t°t°t°POWER SOURCE~ 220/23
- Page 23 and 24: 1.4. Noise levels'11 • SCM-DB-109
- Page 25 and 26: ModelNoiseLevelModelNoiseLevelSound
- Page 27 and 28: '11 • SCM-DB-1091.5. Installation
- Page 30 and 31: lethatof ailarlue.'11 • SCM-DB-10
- Page 32: 6CNEREDunits.readblesition.rm.nnoti
- Page 35 and 36: '11 • SCM-DB-109(3) Models SCM71Z
- Page 37 and 38: φφφφ'11 • SCM-DB-109
- Page 39 and 40: '11 • SCM-DB-109(4) Models SCM100
- Page 43: 2. INDOOR UNITS2.1 Specifications(1
- Page 47 and 48: ItemModelCooling capacity (1) W 600
- Page 49 and 50: ItemModelCooling capacity (1) W 350
- Page 51 and 52: ItemModelCooling capacity (1) W 250
- Page 53 and 54: ItemModelCooling capacity (1) W 500
- Page 55 and 56: Item(2) Floor standing type (SRF)Mo
- Page 57 and 58: ItemModelCooling capacity (1) W 500
- Page 59: ItemModelCooling capacity (1) W 350
- Page 62 and 63: ItemPower source(4) Ceiling cassett
- Page 64 and 65: ItemPower sourceModel'11 • SCM-DB
- Page 66 and 67: ItemPower sourceModel'11 • SCM-DB
- Page 68 and 69: 61.546.5Service space881.926 59.959
- Page 70 and 71: 4514.560790798603145294SymbolConten
- Page 72 and 73: 554191090109864443.555248SymbolABCD
- Page 74 and 75: SymbolABCDEFGContentGas piping12.71
- Page 76 and 77: 530 Suspension bolts pitchG326350AB
- Page 78 and 79: '11 • SCM-DB-109(6) Duct connecte
- Page 80 and 81: '11 • SCM-DB-109(b) Wired remote
- Page 82 and 83: DISPLAY12WIRELESS RECEIVERBACK-UP S
- Page 84 and 85: DISPLAYWIRELESS RECEIVERBACK-UP SWT
- Page 86 and 87: DISPLAYWIRELESS RECEIVER 10BACK-UP
- Page 88 and 89: PJA003Z340 BCNBZDMF200203FM IFSLED2
- Page 90 and 91: Connecting line betweenindoor unit
- Page 92 and 93: ModelNoiseLevelModelNoiseLevelSound
ItemModelCooling capacity (1) W 2500Heating capacity (1) W 3400Power supplyNoise levelCoolingHeating'11 • SCM-DB-109Adapted to RoHS directiveSRK25ZJX-S1 Phase, 220~240 V, 50HzFine snow(8.0Y 9.3/0.1) near equivalentLouver fins & inner grooved tubingMicrocomputer controlHi: 12.5 Me: 9.0 Lo: 5.0Not possibleWireless-Remote controlMicrocomputer thermostatRUN: Green, TIMER: Yellow, HI POWER: Green,3D AUTO: Green, ECONO: BlueFlare connectingLiquid line : 0.55Gas Line : 0.49Necessary (Both sides), independent1.5mm 2 x 4 cores (Including earth cable)Terminal block (Screw fixing type)Interface kit (SC-BIKN-E)The pipe length is 7.5m.StandardsISO-T1, JIS C 9612RWA000Z229 B- 43 -Sound level dB(A) Hi: 41 Me: 31 Lo: 22Power level dB 55Sound level dB(A) Hi: 41 Me: 34 Lo: 27Power level dB 58Exterior dimensions (Height x Width x Depth) mm 309 x 890 x 220Exterior appearance(Munsell color)Net weight kg 15RefrigerantequipmentAir handlingequipmentOperationcontrolSafety devicesInstallationdataHeat exchangerDevice controlFan type & Q'ty Tangential fan x 1Motor W 27Air flow Cooling CMMHeating Hi: 13.0 Me: 10.0 Lo: 7.5Fresh air intakeAir filter, Quality / Quantity Polypropylene net (washable) x 2Operation switchRoom temperature controlOperation DisplayFrost protection, Serial signal error protection, Indoor fan motor error protectionRefrigerant piping size (O.D) mm Liquid line:φ6.35 (1/4") Gas line:φ9.52 (3/8")Connecting methodAttached length of pipingInsulation for pipingmDrain hose Connectable (VP 16)Connection wiringSize x Core numberConnecting methodAccessories (included) Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)Optional partsNote (1) The data are measured at the following conditions.OperationItemIndoor air temperatureOutdoor air temperatureDB WB DB WBCooling 27˚C 19˚C 35˚C 24˚CHeating 20˚C — 7˚C 6˚C(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) The operation data are applied to the 220/230/240V districts respectively.