DATA BOOK - BVT Partners OÃ
DATA BOOK - BVT Partners OÃ DATA BOOK - BVT Partners OÃ
(1) Set the Super Link network address with SW1 (tens place), SW2 (ones place),and SW3 (hundreds place).(2) Set the SL E board SW3-1 to be ON (Master) when using this without any remotecontroller (no wired remote controller nor wireless remote controller).(3) Set up the plural master/slave device using the dip switches on the indoor unitboard.(4) Set up the remote controller master/slave device using the slide switch on the remotecontroller board.(5) Set up “0” to “F” using the address rotary switch on the indoor unit board whencontrolling the indoor unit with the multiple remote controller.6 Installation1. When using the metal box (mounted on the indoor unit / mounted on theback of the remote controller):(1) Mount the SL E board in the metal box using the locking supports.(2) Wiring should go through the provided grommet since then through thewiring to the hole on the Metal box.Secure the grommet after inserting the grommet into the Metal box asshown in below figure, then tie the wiring at the outlet of the unit using abinding band.'11 • SCM-DB-109Connect grounding. Connect grounding for the power line to Ground , and grounding forthe signal line to Ground or to the Ground on the indoor unit control box.2. When connecting to the indoor unit control box (ceiling-concealed type and FDTtype only):(1) Mount the SL E board in the control box using the locking supports.(2) Remove 6 bands from the box and put the wiring through the bands to besecured.Electrical shock hazard! Make sure to turn the power off for servicing. Be cautious so thatno abnormal force should be applied to the wiring. Do not let the SL E board hung by thewiring. Do not damage the board with a screw driver.The board is sensitive to static electricity. Release the static electricity of your body beforeservicing.(you can do this by touching the control board which is grounded).Location of installationInstall the device at the location where there are no electromagnetic waves nor where thereis water and dust. The specified temperature range of the device is 0 to 40. Install thedevice at the location where the ambient temperature stays within the range. If it exceedsthe specification, make sure to provide solution such as installing a cooling fan. When usedoutside of the range, it may cause abnormal operation.7 Indicator displayCheck the LED 3 (green) and LED 2 (red) on the SL E board for flashing.SL E board LEDsDisplay on theRed GreenInspection modeintegrated networkcontrol deviceOff Flashing Normal communicationDisconnection in the remote controller Nocommunication line (X or Y)correspondingShort-circuit in the remote controller unit numberOff Off communication line (between X and Y)Faulty indoor unit remote controller powerFaulty remote controller communication circuitFaulty CPU on SL E boardDisconnection in the Super Link signalline (A or B)One flash Flashing Short-circuit in the Super Link signalline (between A and B)Faulty Super Link signal circuitFaulty address setting for the SL EboardTwoFlashing (Set up the address forflashesprevious SL E board : more than 48new SL E board : more than 128)ThreeSL E board parent not set up when usedFlashing without a remote controllerflashesFaulty remote controller communication circuitE1Address overlapping for the SL E boardFourFlashing and the Super Link network connectedflashesindoor unitE2Off FlashingNumber of connected devices exceeds thespecification for the multiple indoor unit controlE10
7.6 Ducted type (SRRM) optional partsTable of optional parts1 Bottom air inlet grille set 2 Rear inlet filter set3 Duct joint for air outlet plate 4 Drain up kitRTS12RBF12RFJ22RDU12E(1) Bottom air inlet grille set(a) Part No.: RTS12(b) Parts listNameAir inlet grilleDuct for air inlet grilleTapping screwPan-head screwsQty.11104(c) Installation Unit: mm117401145511.5Indoor unitAir outlet sideIndoor unit23080 ~ 100222(10)210762 (Ceiling opening dimensions)782 (Panel dimensions)(d) Installation procedure1) Mount the duct for the air inlet grille to the indoor unitusing the 10 tapping screws provided. The tapping screwson the drain pan receiver side are also used for mountingthe duct for the air inlet grille. They must first be removedand reinstalled after the duct for the air inlet grille is inplace. A guideline for the height is to secure the assemblyso that the lower surface of the duct for the intake grille isapproximately 10 mm above the bottom surface of theceiling.2) Remove the center screw for the air inlet grille and openthe grille as shown in the illustration. Next, insert the airinlet grille into the duct for the air inlet grille and secure itwith the pan-head screws (the long screws).3) Use the pan-head screws to make the small adjustmentsin height. The height dimension on the installation diagramallows for adjustment within range of 80 to 100 mm.If the pan-head screws are completely tightened, the heightwill be 80 mm.1010Ceiling surface(Drain pan receiver)Pan-head screw258 (Ceiling opening dimensions)278 (Ceiling opening dimensions)10Indoor unitDuct for air inlet grilleTapping screwAir inlet grille- 237-1 -
- Page 187 and 188: Indoor unitcombination6roomRoom coo
- Page 189 and 190: Indoor unitcombination4roomRoom hea
- Page 191 and 192: Indoor unitcombination5room6roomRoo
- Page 193 and 194: Indoor unitcombination1room2room3ro
- Page 195 and 196: Indoor unitcombination4roomRoom coo
- Page 197 and 198: Indoor unitcombination5room6roomCoo
- Page 199 and 200: Indoor unitcombination1room2room3ro
- Page 201 and 202: Indoor unitcombination4roomRoom hea
- Page 203 and 204: Indoor unitcombination5room6roomRoo
- Page 205 and 206: '11 • SCM-DB-1096. SELECTION CHAR
- Page 207 and 208: te controllerly unexpected stress o
- Page 209 and 210: The functional settingThe initial f
- Page 211 and 212: y defined as following table.it.flo
- Page 213 and 214: ote controllerto apply unexpected s
- Page 215 and 216: '11 • SCM-DB-109The functional se
- Page 217 and 218: s automatically defined as followin
- Page 219 and 220: Remote controllerInstallation of th
- Page 221 and 222: 3 '11 • SCM-DB-109
- Page 223 and 224: 3 4 '11 • SCM-DB-109 - 222 -
- Page 225 and 226: '11 • SCM-DB-1094 Remotecontrolle
- Page 227 and 228: Remote control installation dimensi
- Page 229 and 230: - 228 - How to set functions by but
- Page 231 and 232: failure.2 cores× 2 cores× 2 cores
- Page 233 and 234: '11 • SCM-DB-109Installation of t
- Page 235 and 236: '11 • SCM-DB-109Connection of wir
- Page 237: 7.5 Superlink E board (SC-ADNA-E) P
- Page 241 and 242: Air flow and external static pressu
- Page 243 and 244: 4) Use hard PVC general purpose pip
- Page 245 and 246: - 239 - PJZ012D076'11 • SCM-DB-10
7.6 Ducted type (SRRM) optional partsTable of optional parts1 Bottom air inlet grille set 2 Rear inlet filter set3 Duct joint for air outlet plate 4 Drain up kitRTS12RBF12RFJ22RDU12E(1) Bottom air inlet grille set(a) Part No.: RTS12(b) Parts listNameAir inlet grilleDuct for air inlet grilleTapping screwPan-head screwsQty.11104(c) Installation Unit: mm117401145511.5Indoor unitAir outlet sideIndoor unit23080 ~ 100222(10)210762 (Ceiling opening dimensions)782 (Panel dimensions)(d) Installation procedure1) Mount the duct for the air inlet grille to the indoor unitusing the 10 tapping screws provided. The tapping screwson the drain pan receiver side are also used for mountingthe duct for the air inlet grille. They must first be removedand reinstalled after the duct for the air inlet grille is inplace. A guideline for the height is to secure the assemblyso that the lower surface of the duct for the intake grille isapproximately 10 mm above the bottom surface of theceiling.2) Remove the center screw for the air inlet grille and openthe grille as shown in the illustration. Next, insert the airinlet grille into the duct for the air inlet grille and secure itwith the pan-head screws (the long screws).3) Use the pan-head screws to make the small adjustmentsin height. The height dimension on the installation diagramallows for adjustment within range of 80 to 100 mm.If the pan-head screws are completely tightened, the heightwill be 80 mm.1010Ceiling surface(Drain pan receiver)Pan-head screw258 (Ceiling opening dimensions)278 (Ceiling opening dimensions)10Indoor unitDuct for air inlet grilleTapping screwAir inlet grille- 237-1 -