'11 • SCM-DB-109Functions of CNT connectorIt is available to operate the air conditioning unit and to monitor the operation status with the external control unit (remote display)by sending the input/output signal through CNT connector on the indoor control PCB.0.3 mm 2 (Keep the distance between the relay and theCNT terminal within 2 m.)1Connect a external remote control unit (locally procured)to CNT terminal.1Common2In case of the pulse input, switch OFF the DIP switch2 XR1Output 1XR1SW2-1 on the interface PCB.3 XR2Output 2 AC 220~240VXR2CNT3When setting operation permission/prohibition mode, connector 4 XR3Output 3XR3switch OFF the DIP switch SW2-3 on the interface PCB.5 XR4Output 4XR46XR5 { Input Power supplyXR5DC 12/24V orAC 220~240V●XR1~4 are for the DC 12V relayInput/Output signalOutput FunctionContent●XR5Relay ON/OFFis a DC 12/24V or AC 220~240V relayOutput 1 Operation output XR1 ON During air-conditioner operation ●CNT connector (local) maker, modelOutput 2 Heating outputXR2 ON During heating operationOutput 3 Compressor operation outputConnector Molex 5264-06XR3 ON During compressor runningOutput 4 Malfunction output XR4 ON During anomalous stopTerminals Molex 5263TSW2-1SW2-3Input/Air- Operation byFunctionInput signalDIP switchOutputSetting Setting Content Conditioner Remote Controller(SW2-3)Level/Pulse XR5OFF→ONONON*External inputON→OFFOFF AllowedON* Level input LevelOFF→ON Operation permission OFFInput ExternalOFFcontrolON→OFF Operation prohibition OFF Not allowedinputOFF→ONDIP switchON* Pulse OFF→ON External inputON→OFF Allowed(SW2-1)OFF Pulse inputOFF→ON Operation permission ONOFF LevelON→OFF Operation prohibition OFF Not allowed* Factory settingConnection of superlink E boardRegarding the connection of superlink E board, refer to the instruction manual of superlink E board.For electrical work, power supply for all of units in the super link systemmust be turned OFF.1Switch ON the DIP switch SW2-2 (Factory setting: ON) on the interface PCB.DIP switchCaution:Wireless remote controller attached to the indoor unit can be used in parallel, after(SW2-2)connecting the wired remote controller. However, some of functions other thanthe basic functions such as RUN/STOP, Temperature Setting, etc. may not workproperly and may have a mismatch between the display and the actual behavior.2Wiring connection between the interface and the superlink E board.Interface sideSuperlink E boardNo. Names of recommended signal wires1 Shielded wireTerminalTerminalblock for YY2 Vinyl cabtyre round cordblock forSuper link3 Vinyl cabtyre round cableiterfaceE board XX4 Vinyl insulated wirevinyl sheathed cable for controlWithin 200 m 0.5 mm 2 2 coresWithin 300 m 0.75 mm 2 2 coresWithin 400 m 1.25 mm 2 2 coresWithin 600 m 2.0 mm 2 2 cores3Clamp the connection cables with cable clamps.- 233 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!