7.3 Simple wired remote controller (RCH-E3)Notes:Following functions of Type -D indoor unit series are not able to be set with this simple wired remote controller (RCH-E3).1. Individual flap control system (for FDT/FDTC)2. Flap control system (for FDEN)3. 4-fan speed setting (PHi/Hi/Me/Lo) 3-fan speed setting (Hi/Me/Lo) (for FDT/FDTC/FDUM/FDEN)'11 • SCM-DB-109Names and functions of sectionsRemote controller sensorOperation/Inspection lampON/OFF buttonDuring operation: GreenButton to start/stop the air conditionerfailure: RedMODE buttonUse to select the mode.FAN SPEED buttonButton to set the fan speedTEMP buttonUse to raise the setting temperature.TEMP buttonAIR CON No. buttonUse to lower the setting temperature.Indicates the No. of air conditionerwhich is connected.Operation mode display Indoor unit No. display VRF series outdoor unit No. display: Cooling: Drying: Fan operation: Heating: Auto modeFan speed displayCentral control displayDisplayed when controlling theunit with the central controller.Ventilation displayThis is lit during the ventilationoperation.Control disable displaySetting TEMP displayThe lamp is lit for 3 secondsError code displaywhen a disabled button ispressed.Installation of remote controllerDO NOT install the remote controller at the following places in order to avoid malfunction.(1) Places exposed to direct sunlight (4) Hot surface or cold surface enough to generate condensation(2) Places near heat devices(5) Places exposed to oil mist or steam directly(3) High humidity places(6) Uneven surfacePJZ000Z272 aRemWiring o(In case of embe12×7 SlIn ca0.3mmLWirin(1)(2)

Remote control installation dimensions83.533.5Wiring outlet(In case of embedding wiring)12×7 Slot hole16Wiring specifications67In case of exposing wiring117Installation hole9×4.5 Slot hole (2 places)Note: Installation screw for remote controllerM4 Screw (2 pieces)0.3mm 2 ×2 cores.L C DLength70120X, Y Terminal blockAttach M3 screwwith washer(1) Wiring of remote controller should use 0.3mm 2 2 core wires or cables. (on-site configuration)(2) Maximum prolongation of remote controller wiring is 600m.If the prolongation is over 100m, change to the size below.But, the wiring in the remote controller case should be 0.3mm 2 (recommended) to 0.5mm 2 .Change the wire size outside of the case according to wire connecting. Waterproof treatment isnecessary at the wireconnecting section. Be careful about contact failure.Wiring thickness100 to 200m 0.5mm 2 ×2 coresUnder 300m0.75mm 2 ×2 coresUnder 400m1.25mm 2 ×2 coresUnder 600m2.0mm 2 ×2 cores'11 • SCM-DB-109MITSUBISHI HEAVY INDUSTRIES,LTD.AIR-CONDITIONING & REFRIGERATION SYSTEMS HEADQUARTERSIn case of embedding wiringWall surfaceWiringElectrical box(Prepare on site)15The remote controller wiring can be extracted from the upper center.After the thin part in the upper side of the remote controller uppercase is scraped with a nipper or knife, remove burr with a file.Thin partUpper caseSheathUpper caseX YwiringThe peeling length of each wiring is as follows:X wiring : 160mmY wiring : 150mmSheathPeeling lengthUnit:mmAdapted to RoHS directive- 226 -

Remote control installation dimensions83.533.5Wiring outlet(In case of embedding wiring)12×7 Slot hole16Wiring specifications67In case of exposing wiring117Installation hole9×4.5 Slot hole (2 places)Note: Installation screw for remote controllerM4 Screw (2 pieces)0.3mm 2 ×2 cores.L C DLength70120X, Y Terminal blockAttach M3 screwwith washer(1) Wiring of remote controller should use 0.3mm 2 2 core wires or cables. (on-site configuration)(2) Maximum prolongation of remote controller wiring is 600m.If the prolongation is over 100m, change to the size below.But, the wiring in the remote controller case should be 0.3mm 2 (recommended) to 0.5mm 2 .Change the wire size outside of the case according to wire connecting. Waterproof treatment isnecessary at the wireconnecting section. Be careful about contact failure.Wiring thickness100 to 200m 0.5mm 2 ×2 coresUnder 300m0.75mm 2 ×2 coresUnder 400m1.25mm 2 ×2 coresUnder 600m2.0mm 2 ×2 cores'11 • SCM-DB-109MITSUBISHI HEAVY INDUSTRIES,LTD.AIR-CONDITIONING & REFRIGERATION SYSTEMS HEADQUARTERSIn case of embedding wiringWall surfaceWiringElectrical box(Prepare on site)15The remote controller wiring can be extracted from the upper center.After the thin part in the upper side of the remote controller uppercase is scraped with a nipper or knife, remove burr with a file.Thin partUpper caseSheathUpper caseX YwiringThe peeling length of each wiring is as follows:X wiring : 160mmY wiring : 150mmSheathPeeling lengthUnit:mmAdapted to RoHS directive- 226 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!