7.3 Simple wired remote controller (RCH-E3)Notes:Following functions of Type -D indoor unit series are not able to be set with this simple wired remote controller (RCH-E3).1. Individual flap control system (for FDT/FDTC)2. Flap control system (for FDEN)3. 4-fan speed setting (PHi/Hi/Me/Lo) 3-fan speed setting (Hi/Me/Lo) (for FDT/FDTC/FDUM/FDEN)'11 • SCM-DB-109Names and functions of sectionsRemote controller sensorOperation/Inspection lampON/OFF buttonDuring operation: GreenButton to start/stop the air conditionerfailure: RedMODE buttonUse to select the mode.FAN SPEED buttonButton to set the fan speedTEMP buttonUse to raise the setting temperature.TEMP buttonAIR CON No. buttonUse to lower the setting temperature.Indicates the No. of air conditionerwhich is connected.Operation mode display Indoor unit No. display VRF series outdoor unit No. display: Cooling: Drying: Fan operation: Heating: Auto modeFan speed displayCentral control displayDisplayed when controlling theunit with the central controller.Ventilation displayThis is lit during the ventilationoperation.Control disable displaySetting TEMP displayThe lamp is lit for 3 secondsError code displaywhen a disabled button ispressed.Installation of remote controllerDO NOT install the remote controller at the following places in order to avoid malfunction.(1) Places exposed to direct sunlight (4) Hot surface or cold surface enough to generate condensation(2) Places near heat devices(5) Places exposed to oil mist or steam directly(3) High humidity places(6) Uneven surfacePJZ000Z272 aRemWiring o(In case of embe12×7 SlIn ca0.3mmLWirin(1)(2)
Remote control installation dimensions83.533.5Wiring outlet(In case of embedding wiring)12×7 Slot hole16Wiring specifications67In case of exposing wiring117Installation hole9×4.5 Slot hole (2 places)Note: Installation screw for remote controllerM4 Screw (2 pieces)0.3mm 2 ×2 cores.L C DLength70120X, Y Terminal blockAttach M3 screwwith washer(1) Wiring of remote controller should use 0.3mm 2 2 core wires or cables. (on-site configuration)(2) Maximum prolongation of remote controller wiring is 600m.If the prolongation is over 100m, change to the size below.But, the wiring in the remote controller case should be 0.3mm 2 (recommended) to 0.5mm 2 .Change the wire size outside of the case according to wire connecting. Waterproof treatment isnecessary at the wireconnecting section. Be careful about contact failure.Wiring thickness100 to 200m 0.5mm 2 ×2 coresUnder 300m0.75mm 2 ×2 coresUnder 400m1.25mm 2 ×2 coresUnder 600m2.0mm 2 ×2 cores'11 • SCM-DB-109MITSUBISHI HEAVY INDUSTRIES,LTD.AIR-CONDITIONING & REFRIGERATION SYSTEMS HEADQUARTERSIn case of embedding wiringWall surfaceWiringElectrical box(Prepare on site)15The remote controller wiring can be extracted from the upper center.After the thin part in the upper side of the remote controller uppercase is scraped with a nipper or knife, remove burr with a file.Thin partUpper caseSheathUpper caseX YwiringThe peeling length of each wiring is as follows:X wiring : 160mmY wiring : 150mmSheathPeeling lengthUnit:mmAdapted to RoHS directive- 226 -
- Page 175 and 176: Indoor unitcombination4roomRoom hea
- Page 177 and 178: Indoor unitcombination1room2room3ro
- Page 179 and 180: Indoor unitcombination4room5roomRoo
- Page 181 and 182: Indoor unitcombination3room4roomRoo
- Page 183 and 184: Indoor unitcombination1room2room3ro
- Page 185 and 186: Indoor unitcombination4room5roomRoo
- Page 187 and 188: Indoor unitcombination6roomRoom coo
- Page 189 and 190: Indoor unitcombination4roomRoom hea
- Page 191 and 192: Indoor unitcombination5room6roomRoo
- Page 193 and 194: Indoor unitcombination1room2room3ro
- Page 195 and 196: Indoor unitcombination4roomRoom coo
- Page 197 and 198: Indoor unitcombination5room6roomCoo
- Page 199 and 200: Indoor unitcombination1room2room3ro
- Page 201 and 202: Indoor unitcombination4roomRoom hea
- Page 203 and 204: Indoor unitcombination5room6roomRoo
- Page 205 and 206: '11 • SCM-DB-1096. SELECTION CHAR
- Page 207 and 208: te controllerly unexpected stress o
- Page 209 and 210: The functional settingThe initial f
- Page 211 and 212: y defined as following table.it.flo
- Page 213 and 214: ote controllerto apply unexpected s
- Page 215 and 216: '11 • SCM-DB-109The functional se
- Page 217 and 218: s automatically defined as followin
- Page 219 and 220: Remote controllerInstallation of th
- Page 221 and 222: 3 '11 • SCM-DB-109
- Page 223 and 224: 3 4 '11 • SCM-DB-109 - 222 -
- Page 225: '11 • SCM-DB-1094 Remotecontrolle
- Page 229 and 230: - 228 - How to set functions by but
- Page 231 and 232: failure.2 cores× 2 cores× 2 cores
- Page 233 and 234: '11 • SCM-DB-109Installation of t
- Page 235 and 236: '11 • SCM-DB-109Connection of wir
- Page 237 and 238: 7.5 Superlink E board (SC-ADNA-E) P
- Page 239 and 240: 7.6 Ducted type (SRRM) optional par
- Page 241 and 242: Air flow and external static pressu
- Page 243 and 244: 4) Use hard PVC general purpose pip
- Page 245 and 246: - 239 - PJZ012D076'11 • SCM-DB-10
Remote control installation dimensions83.533.5Wiring outlet(In case of embedding wiring)12×7 Slot hole16Wiring specifications67In case of exposing wiring117Installation hole9×4.5 Slot hole (2 places)Note: Installation screw for remote controllerM4 Screw (2 pieces)0.3mm 2 ×2 cores.L C DLength70120X, Y Terminal blockAttach M3 screwwith washer(1) Wiring of remote controller should use 0.3mm 2 2 core wires or cables. (on-site configuration)(2) Maximum prolongation of remote controller wiring is 600m.If the prolongation is over 100m, change to the size below.But, the wiring in the remote controller case should be 0.3mm 2 (recommended) to 0.5mm 2 .Change the wire size outside of the case according to wire connecting. Waterproof treatment isnecessary at the wireconnecting section. Be careful about contact failure.Wiring thickness100 to 200m 0.5mm 2 ×2 coresUnder 300m0.75mm 2 ×2 coresUnder 400m1.25mm 2 ×2 coresUnder 600m2.0mm 2 ×2 cores'11 • SCM-DB-109MITSUBISHI HEAVY INDUSTRIES,LTD.AIR-CONDITIONING & REFRIGERATION SYSTEMS HEADQUARTERSIn case of embedding wiringWall surfaceWiringElectrical box(Prepare on site)15The remote controller wiring can be extracted from the upper center.After the thin part in the upper side of the remote controller uppercase is scraped with a nipper or knife, remove burr with a file.Thin partUpper caseSheathUpper caseX YwiringThe peeling length of each wiring is as follows:X wiring : 160mmY wiring : 150mmSheathPeeling lengthUnit:mmAdapted to RoHS directive- 226 -