'11 • SCM-DB-1094. RANGE OF USAGE & LIMITATIONSModels SCM40, 45, 50, 60ItemIndoor intake air temperature(Upper, lower limits)Outdoor air temperature(Upper, lower limits)Indoor unitsthat can beused incombinationModelsCoolingHeatingCoolingHeatingNumber of connected unitsTotal of indoor Units (class kW)SCM40ZJ-SSCM45ZJ-SSCM50ZJ-S1Approximately 18 to 32Approximately 15 to 30Approximately -15 to 43Approximately -15 to 242 units 2 to 3 unitsSCM60ZJ-S16.0kW 7.0kW 8.5kW11.0kWTotal length for all roomsMax. 30mMax. 40mLength for one indoor unitDifference inheight betweenindoor and outdoorunitsWhen indoor unit is aboveoutdoor unit (A)When indoor unit is belowoutdoor unit (B)Difference in height between indoor units (C)Max. 25mMax. 15mMax. 15mMax. 25mCompressorstop/startfrequencyPower sourcevoltage1 cycle timeStop timeVoltage fluctuationVoltage drop during startInterval unbalance8 min or more (from stop to stop or from start to start)3 min or moreWithin ±10% of rated voltageWithin ±15% of rated voltageWithin ±3% of rated voltagePower cable length 32m (1)Note(1) The cable specifications are based on the assumption that a metal or plastic conduit is used with no more than three cablescontained in a conduit and a voltage drop is 2%. For an installation falling outside of these conditions, please follow the internalcabling regulations. Adapt it to the regulation in effect in each country.CAB- 145 -
'11 • SCM-DB-109Models SCM71, 80, 100, 125ItemIndoor intake air temperature(Upper, lower limits)Outdoor air temperature(Upper, lower limits)Indoor unitsthat can beused incombinationModelsCoolingHeatingCoolingHeatingNumber of connected unitsTotal of indoor Units (class kW)SCM71ZJ-S12 to 4 unitsSCM80ZJ-S1SCM100ZJ-S1Approximately 18 to 32Approximately 15 to 30Approximately -15 to 43Approximately -15 to 24SCM125ZJ-S14 (1) to 5 units 4 (1) to 6 units12.5kW 13.5kW 16.0kW 19.5kWTotal length for all roomsMax. 70mMax. 90mLength for one indoor unitDifference inheight betweenindoor and outdoorunitsWhen indoor unit is aboveoutdoor unit (A)When indoor unit is belowoutdoor unit (B)Difference in height between indoor units (C)Max. 25mMax. 20mMax. 20mMax. 25mCompressorstop/startfrequencyPower sourcevoltage1 cycle timeStop timeVoltage fluctuationVoltage drop during startInterval unbalance8 min or more (from stop to stop or from start to start)3 min or moreWithin ±10% of rated voltageWithin ±15% of rated voltageWithin ±3% of rated voltagePower cable length 32m (2)Notes(1) In case of combination with SRK-ZJX-S, SRK71ZK-S, FDEN50VD only, 3 Indoor units can be connectable.In case of SRK71ZK-SSRK71ZK-S, 2 Indoor units can be connectable.Notes(2) The cable specifications are based on the assumption that a metal or plastic conduit is used with no more than three cablescontained in a conduit and a voltage drop is 2%. For an installation falling outside of these conditions, please follow the internalcabling regulations. Adapt it to the regulation in effect in each country.ACB- 146 -
- Page 96 and 97: '11 • SCM-DB-109ModelSRK50ZJ-SNoi
- Page 98 and 99: '11 • SCM-DB-109ModelSRK50ZJX-S1N
- Page 100 and 101: '11 • SCM-DB-109ModelSRR60ZJ-SNoi
- Page 102 and 103: ModelNoiseLevelModelNoiseLevelSound
- Page 104 and 105: 2.5 Characteristics of fan'11 • S
- Page 106 and 107: BEFORE INSTALLATION Before installa
- Page 109 and 110: (b) Models SRK25ZJR-S, 35ZJR-SWALL
- Page 111 and 112: RLA012A012BFixing of indoor unitLat
- Page 113 and 114: (c) Model SRK71ZK-SRKW012A400AWALL
- Page 115 and 116: RKW012A400AFixing of indoor unitLat
- Page 117 and 118: (2) Floor standing type (SRF)Models
- Page 119 and 120: Fixing of indoor unitFloor installa
- Page 121 and 122: (3) Ceiling concealod type (SRR)Mod
- Page 123 and 124: Plan45551530Hanging b30 230150236Dr
- Page 125 and 126: (4) Ceiling cassette-4way compact t
- Page 127 and 128: 4 Installation of indoor unit (cont
- Page 129 and 130: PJA012D783- 128 - '11 • SCM-DB-10
- Page 131 and 132: (5) Ceiling suspended type (FDEN)Th
- Page 133 and 134: Installation of indoor unitWork pro
- Page 135 and 136: '11 • SCM-DB-109(6) Duct connecte
- Page 137 and 138: 5Duct Work1A corrugated board (for
- Page 139 and 140: 8Wiring-out position and wiring con
- Page 141 and 142: Gas lineIndoor unitOutdoor unitServ
- Page 143 and 144: Outdoor UnitCooling cycleHeating cy
- Page 145: - 144 -Gas lineLiquid line*1 Servic
- Page 149 and 150: Indoor unitcombination1room2roomInd
- Page 151 and 152: Indoor unitcombination1room2room3ro
- Page 153 and 154: Indoor unitcombination1room2room3ro
- Page 155 and 156: Indoor unitcombination1room2room3ro
- Page 157 and 158: (5) Model SCM71ZJ-S1(a) Indoor unit
- Page 159 and 160: Indoor unitcombination3room4roomRoo
- Page 161 and 162: Indoor unitcombination4roomIndoor u
- Page 163 and 164: (6) Model SCM80ZJ-S1(a) Indoor unit
- Page 165 and 166: Indoor unitcombination1room2room3ro
- Page 167 and 168: Indoor unitcombination1room2room3ro
- Page 169 and 170: Indoor unitcombination1room2room3ro
- Page 171 and 172: (7) Model SCM100ZJ-S1(a) Indoor uni
- Page 173 and 174: Indoor unitcombination5roomRoom coo
- Page 175 and 176: Indoor unitcombination4roomRoom hea
- Page 177 and 178: Indoor unitcombination1room2room3ro
- Page 179 and 180: Indoor unitcombination4room5roomRoo
- Page 181 and 182: Indoor unitcombination3room4roomRoo
- Page 183 and 184: Indoor unitcombination1room2room3ro
- Page 185 and 186: Indoor unitcombination4room5roomRoo
- Page 187 and 188: Indoor unitcombination6roomRoom coo
- Page 189 and 190: Indoor unitcombination4roomRoom hea
- Page 191 and 192: Indoor unitcombination5room6roomRoo
- Page 193 and 194: Indoor unitcombination1room2room3ro
- Page 195 and 196: Indoor unitcombination4roomRoom coo
'11 • SCM-DB-109Models SCM71, 80, 100, 125ItemIndoor intake air temperature(Upper, lower limits)Outdoor air temperature(Upper, lower limits)Indoor unitsthat can beused incombinationModelsCoolingHeatingCoolingHeatingNumber of connected unitsTotal of indoor Units (class kW)SCM71ZJ-S12 to 4 unitsSCM80ZJ-S1SCM100ZJ-S1Approximately 18 to 32Approximately 15 to 30Approximately -15 to 43Approximately -15 to 24SCM125ZJ-S14 (1) to 5 units 4 (1) to 6 units12.5kW 13.5kW 16.0kW 19.5kWTotal length for all roomsMax. 70mMax. 90mLength for one indoor unitDifference inheight betweenindoor and outdoorunitsWhen indoor unit is aboveoutdoor unit (A)When indoor unit is belowoutdoor unit (B)Difference in height between indoor units (C)Max. 25mMax. 20mMax. 20mMax. 25mCompressorstop/startfrequencyPower sourcevoltage1 cycle timeStop timeVoltage fluctuationVoltage drop during startInterval unbalance8 min or more (from stop to stop or from start to start)3 min or moreWithin ±10% of rated voltageWithin ±15% of rated voltageWithin ±3% of rated voltagePower cable length 32m (2)Notes(1) In case of combination with SRK-ZJX-S, SRK71ZK-S, FDEN50VD only, 3 Indoor units can be connectable.In case of SRK71ZK-SSRK71ZK-S, 2 Indoor units can be connectable.Notes(2) The cable specifications are based on the assumption that a metal or plastic conduit is used with no more than three cablescontained in a conduit and a voltage drop is 2%. For an installation falling outside of these conditions, please follow the internalcabling regulations. Adapt it to the regulation in effect in each country.ACB- 146 -