DATA BOOK - BVT Partners OÃ
DATA BOOK - BVT Partners OÃ DATA BOOK - BVT Partners OÃ
BEFORE INSTALLATIONBefore installation check that the power supply matches the air conditioner.1234567891012345678910111213Standard accessories (Installation kit)Accessories for indoor unitInstallation board(Attached to the rear of the indoor unit)Wireless remote controlRemote control holderTapping screws(for installation board 4dia. by 25mm)Wood screws(for remote control switch holder 3.5(mm). by 16mm)Battery [R03(AAA,Micro) 1.5V]Air-cleaning filtersFilter holders(Attached to the front panel of indoor unit)Pipe cover (200mm)BandSealing plateSleeveInclination platePuttyOption partsDrain hose (extention hose)Piping cover(for insulation of connection piping)Q'tyNecessary tools for the installation workPlus headed driverKnifeSawTape measureHammerSpanner wrenchTorque wrenchHole core drill (65mm in diameter)Wrench key (Hexagon) [4m/m]Flaring tool setDesigned specificallyGas leak detector for R410AGauge for projection adjustmentUsed when flare is made by using( conventional flare toolPipe bender(14.0 ~ 61.0N m(1.4 ~ 6.1kgf m)Designed( )for R410Aspecifically( )))1119222212Q'ty111111SELECTION OF INSTALLATION LOCATION(Install at location that meets the following conditions, after getting approval from the customer)Indoor unitWhere there is no obstructions to the air flow and where the cooled and heated air can be evenly distributed.A solid place where the unit or the wall will not vibrate.A place where there will be enough space for servicing. (Where space mentioned below can be secured)Where wiring and the piping work will be easy to conduct.The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street lighting.A place where it can be easily drained.A place separated at least 1m away from the television or the radio. (To prevent interference to images and sounds.)Places where this unit is not affected by the high frequency equipment or electric equipment.Avoid installing this unit in place where there is much oil mist.Places where there is no electric equipment or household under the installing unit.Install the indoor unit on flat wall.Wireless remote controlA place where the air conditioner can be received the signal surely during operating the wireless remote control.Places where there is no affected by the TV and radio etc.Do not place where exposed to direct sunlight or near heat devices such as a stove.INSTALLATION OF INDOOR UNITOpen and detachment of the air inlet panelTo open, pull the panel at both ends of upper partand release latches, and undo the strings.Then remove the panel.CAUTIONWhen removing the air-inlet panel,be careful not to drop it on your feet.How to remove the front panel1 Remove the air inlet panel.2 Remove the 5 set screws.3 Remove the 3 latches in the upper section.If the latches are difficult to remove, push the latchportion out using a screw driver, for example.4 Move the lower part of the panel forward andremove the 6 latches in the under section.- 117 - '11 • SCM-DB-109Drilling of holes and fixture of sleeve (Option parts)Piping is possible in the rear,left,left rear, left downward,right or downward direction.RightRearDownward LeftLeft rearLeft downward4518.565Left rear pipingFor Right or Left rear piping8047065 6591.545Latch65Right rear pipingFor Right or Left piping6015 60The screw of the lidis tightened securely.LatchWhen drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use pipe hole sleeve sold separately.Indoor side65Outdoor sideDrill a hole with whole core drill.Indoor unit piping directionDrainageArrange the drain hose in a downward angleAvoid the following drain piping.Higher than specified The drain hosetip is in water5b Topb cThicknese of the wall + 1.5cmIn case of rear piping draw out, cut off the lowerand the right side portions of the sleeve collar.WavyaTurn totightenIndoor side Outdoor side Installed stateCAUTION Go through all installation steps and check if thedralnage is all right. Otherwise water leak may occur.Odor fromthe gutterThe gap to the ground is The drain hose5 cm or lesstip is in the gutter5 cm minimumfrom the wall15 cm or below from the floorRight/Left pipingWireless remote control76.355157.27 cm minimum from the ceilingWood screwsCAUTIONCompletely seal the hole onthe wall with putty. Otherwise,furniture, or other, may bewetted by leaked water ordewing.Installing the support of pipingFor Right or Left bottom pipingLeft bottom piping85.3 22.760100Right bottom pipingRemote control holderIn case of piping in the right rear directionTaping of the exteriorIndoor sideputtyTape only the portionthat goes through thewall.Always tape the wiringwith the piping.Sufficient care must be taken not to damagethe panel when connecting pipes.from the wallOutdoor sidePour water to the drain pan located under the heat exchanger, and ensure that the water is discharged outdoor.When the extended drain hose is indoor, securely insulate it with a heat insulator available in the market.Installation board5 cm +Service space (30cm)Sleeve(sold separately)puttyCAUTIONBe careful not tostress the connectingrefrigerant pipse. (Donot pull with a force oflarger than 5 kgf.) Ifimproperly installed,it may cause abnormalnoise and vibration.
Fixing of indoor unitFloor installationSecure using upper 2 screws for floor installations.If possible, also attach two lower screws.CAUTION During the installation, do not lean on the control box or the display, as they may be damaged.Install the indoor unit on flat wall. If improperly installed, it may cause abnormal noise and vibration. (Distortion on the wall shall be no larger than 3 mm.)58530.5726(860)103.55Wall installationAt first secure the installation board using 5 screws and the indoor unit using 2 screws.Installation of Installation boardLook for the inside wall structures (Intersediatssupport or pillar and finally install the unit after levelsurface has been checked.)Tapping screw58530.583.5726(860)103.5156.55(238)198If there is an obstacle such as a cable cover,cut off the hatched part before installation.30.5 25.5185585595(600)Fixing on concrete wallUse of nut anchorBolt(M6 12) Adjustment of the installation board in the horizontaldirection is to be conducted with five screws in a temporarytightened state.InstallationboardStandard holeAdjust so the board will be level by turning the board withthe standard hole as the center.(238)585595(600)When practicing the half-console, make sure to fix the unit securely.Otherwise, it could fall.CONNECTION OF REFRIGERANT PIPINGSPreparationIndoorKeep the openings of the pipes covered with tapes etc. to prevent dust, sand, etc.from entering them.(Do not turn)RemovePress Remove the flared nuts. (on both liquid and gas sides)CAUTIONDo not apply refrigerating machine oil to the flared surface.• Flaring workFlaringblockMeasurement BCopper pipeCopper pipe diameterø6.35ø9.52ø12.790 ± 0.5°ADimension ALiquid side ø6.35:9.1(mm)Gas side ø9.52:13.2(mm)ø12.7:16.6(mm) Install the removed flared nuts to the pipes tobe connected,then flared the pipes.Clutch type flare tool forR410A0.0 - 0.50.0 - 0.50.0 - 0.5Measurement B (mm)Conventional (R22) flare toolClutch type Wing nut type1.0 - 1.5 1.5 - 2.01.0 - 1.51.0 - 1.51.5 - 2.02.0 - 2.5Use a flare tool designed for R410A or a conventional flare tool.Please note that measurement B (protrusion from the flaring block) will vary dependingon the type of a flare tool in use.If a coventional flare tool is used, please use a copper pipe gauge or a similarinstrument to check protrusion so that you can keep measurement B to a correct value.- 118 - '11 • SCM-DB-109CAUTIONDo not apply excess torque to the flared nuts. Otherwise, the flared nuts may check depending.155CAUTIONConnectionIndoor Liquid sideGas side45Be careful not to stress the connecting refrigerant pipes.(Do not pull with a force of larger than 5 kgf.)Insulation of the connection portion105130140(Do not turn)Pass the refrigerant pipe through the piping hole toindoor side.Arrange the pipes according to the direction of piping. Connect the pipes on both liquid and gas sides. Tighten the nuts to the following torque.Liquid side (ø6.35) : 14.0 - 18.0 N·m (1.4 - 1.8 kgf·m)Gas side (ø9.52) : 34.0 - 42.0 N·m (3.4 - 4.2 kgf·m)(ø12.7) : 49.0 - 61.0 N·m (4.9 - 6.1 kgf·m)Position it so that the slit area faces upward.Finishing work and fixingClampCover the coupling with insulator and then cover it with tapes.Use an attached pipe cover for heat insulation.RefrigerantpipeSlitRefrigerantpipeSlitAddTape 10bandRefrigerant pipingConnection wiring,Earth wiring Cover the exterior portion with outer tapeand shape the piping so it will match theOuter tape contours of the route that the piping to take.Drain hoseAlso fix the wiring and pipings to the wallwith clamps.Wood screwRefrigerantpipe9Pipe coverCAUTIONIf heat insulation is insufficient, water leakagemay occur. In addition, the room temperaturesensor may give a false alert due to heatradiation from the pipes.• Cover the indoor unit’s flare-connected joints, afterthey are checked for a gas leak, with an indoor unitheat insulating material and then wrap them with atape with an attached pipe cover placed over theheat insulating material’s slit area.ELECTRICAL WIRING WORKPreparation of indoor unitMounting of connecting wires1 Remove the fixing screw of clamp.2 Connect the connecting wire securely to the terminal block.1 ) Connect the connection wire securely to the terminalblock. If the wire is not affixed completely, contact will bepoor, and it is dangerous as the terminal block may heatup and catch fire.2 ) Take care not to confuse the terminal numbers for indoorand outdoor connections.3 Fix the connecting wire by wiring clamp.4 Pass the connecting wire through the wiring holder.CAUTIONIn case of faulty wiring connection, the indoor unitstops, and then the run lamp turns on and the timerlamp blinks.Use cables for interconnection wiring to avoidloosening of the wires.CENELEC code for cables Required field cables.H05RNR4G1.5 (example) or 245IEC57H Harmonized cable type05 300/500 voltsR Natural-and/or synth, rubber wire insulationN Polychloroprene rubber conductors insulationR Stranded coreCAUTION• During installation, do not lean on the control box or the display, as theymay be damaged.• Pass the connecting wire securely through the wiring holder. If it passeson the sensor, it may not detect suction temperature and/or humidity.Terminal blockClampHow to fit the front panel Fitting1 Do remove the air filter.2 Cover the body with the front panel.3 Fit the 6 latches in the lower section.then 3 latches in the upper section.4 Tighten the 5 set screws.5 Fit the air filter.6 Fit the air inlet panel.Close and attachment of the air inler panel To close, attach the panel after pullingthe strings, hold the panel at both ends ofupper part to lower downward and push itslightly until the latch works.LatchLatch4or5 Number of conductorsG One conductor of the cable is the earthconductor (yellow/green)Fixing screwWiring holder1.5 Section of copper wire (mm 2 )Sensor
- Page 68 and 69: 61.546.5Service space881.926 59.959
- Page 70 and 71: 4514.560790798603145294SymbolConten
- Page 72 and 73: 554191090109864443.555248SymbolABCD
- Page 74 and 75: SymbolABCDEFGContentGas piping12.71
- Page 76 and 77: 530 Suspension bolts pitchG326350AB
- Page 78 and 79: '11 • SCM-DB-109(6) Duct connecte
- Page 80 and 81: '11 • SCM-DB-109(b) Wired remote
- Page 82 and 83: DISPLAY12WIRELESS RECEIVERBACK-UP S
- Page 84 and 85: DISPLAYWIRELESS RECEIVERBACK-UP SWT
- Page 86 and 87: DISPLAYWIRELESS RECEIVER 10BACK-UP
- Page 88 and 89: PJA003Z340 BCNBZDMF200203FM IFSLED2
- Page 90 and 91: Connecting line betweenindoor unit
- Page 92 and 93: ModelNoiseLevelModelNoiseLevelSound
- Page 94 and 95: '11 • SCM-DB-109ModelSRK35ZJR-SNo
- Page 96 and 97: '11 • SCM-DB-109ModelSRK50ZJ-SNoi
- Page 98 and 99: '11 • SCM-DB-109ModelSRK50ZJX-S1N
- Page 100 and 101: '11 • SCM-DB-109ModelSRR60ZJ-SNoi
- Page 102 and 103: ModelNoiseLevelModelNoiseLevelSound
- Page 104 and 105: 2.5 Characteristics of fan'11 • S
- Page 106 and 107: BEFORE INSTALLATION Before installa
- Page 109 and 110: (b) Models SRK25ZJR-S, 35ZJR-SWALL
- Page 111 and 112: RLA012A012BFixing of indoor unitLat
- Page 113 and 114: (c) Model SRK71ZK-SRKW012A400AWALL
- Page 115 and 116: RKW012A400AFixing of indoor unitLat
- Page 117: (2) Floor standing type (SRF)Models
- Page 121 and 122: (3) Ceiling concealod type (SRR)Mod
- Page 123 and 124: Plan45551530Hanging b30 230150236Dr
- Page 125 and 126: (4) Ceiling cassette-4way compact t
- Page 127 and 128: 4 Installation of indoor unit (cont
- Page 129 and 130: PJA012D783- 128 - '11 • SCM-DB-10
- Page 131 and 132: (5) Ceiling suspended type (FDEN)Th
- Page 133 and 134: Installation of indoor unitWork pro
- Page 135 and 136: '11 • SCM-DB-109(6) Duct connecte
- Page 137 and 138: 5Duct Work1A corrugated board (for
- Page 139 and 140: 8Wiring-out position and wiring con
- Page 141 and 142: Gas lineIndoor unitOutdoor unitServ
- Page 143 and 144: Outdoor UnitCooling cycleHeating cy
- Page 145 and 146: - 144 -Gas lineLiquid line*1 Servic
- Page 147 and 148: '11 • SCM-DB-109Models SCM71, 80,
- Page 149 and 150: Indoor unitcombination1room2roomInd
- Page 151 and 152: Indoor unitcombination1room2room3ro
- Page 153 and 154: Indoor unitcombination1room2room3ro
- Page 155 and 156: Indoor unitcombination1room2room3ro
- Page 157 and 158: (5) Model SCM71ZJ-S1(a) Indoor unit
- Page 159 and 160: Indoor unitcombination3room4roomRoo
- Page 161 and 162: Indoor unitcombination4roomIndoor u
- Page 163 and 164: (6) Model SCM80ZJ-S1(a) Indoor unit
- Page 165 and 166: Indoor unitcombination1room2room3ro
- Page 167 and 168: Indoor unitcombination1room2room3ro
BEFORE INSTALLATIONBefore installation check that the power supply matches the air conditioner.1234567891012345678910111213Standard accessories (Installation kit)Accessories for indoor unitInstallation board(Attached to the rear of the indoor unit)Wireless remote controlRemote control holderTapping screws(for installation board 4dia. by 25mm)Wood screws(for remote control switch holder 3.5(mm). by 16mm)Battery [R03(AAA,Micro) 1.5V]Air-cleaning filtersFilter holders(Attached to the front panel of indoor unit)Pipe cover (200mm)BandSealing plateSleeveInclination platePuttyOption partsDrain hose (extention hose)Piping cover(for insulation of connection piping)Q'tyNecessary tools for the installation workPlus headed driverKnifeSawTape measureHammerSpanner wrenchTorque wrenchHole core drill (65mm in diameter)Wrench key (Hexagon) [4m/m]Flaring tool setDesigned specificallyGas leak detector for R410AGauge for projection adjustmentUsed when flare is made by using( conventional flare toolPipe bender(14.0 ~ 61.0N m(1.4 ~ 6.1kgf m)Designed( )for R410Aspecifically( )))1119222212Q'ty111111SELECTION OF INSTALLATION LOCATION(Install at location that meets the following conditions, after getting approval from the customer)Indoor unitWhere there is no obstructions to the air flow and where the cooled and heated air can be evenly distributed.A solid place where the unit or the wall will not vibrate.A place where there will be enough space for servicing. (Where space mentioned below can be secured)Where wiring and the piping work will be easy to conduct.The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street lighting.A place where it can be easily drained.A place separated at least 1m away from the television or the radio. (To prevent interference to images and sounds.)Places where this unit is not affected by the high frequency equipment or electric equipment.Avoid installing this unit in place where there is much oil mist.Places where there is no electric equipment or household under the installing unit.Install the indoor unit on flat wall.Wireless remote controlA place where the air conditioner can be received the signal surely during operating the wireless remote control.Places where there is no affected by the TV and radio etc.Do not place where exposed to direct sunlight or near heat devices such as a stove.INSTALLATION OF INDOOR UNITOpen and detachment of the air inlet panelTo open, pull the panel at both ends of upper partand release latches, and undo the strings.Then remove the panel.CAUTIONWhen removing the air-inlet panel,be careful not to drop it on your feet.How to remove the front panel1 Remove the air inlet panel.2 Remove the 5 set screws.3 Remove the 3 latches in the upper section.If the latches are difficult to remove, push the latchportion out using a screw driver, for example.4 Move the lower part of the panel forward andremove the 6 latches in the under section.- 117 - '11 • SCM-DB-109Drilling of holes and fixture of sleeve (Option parts)Piping is possible in the rear,left,left rear, left downward,right or downward direction.RightRearDownward LeftLeft rearLeft downward4518.565Left rear pipingFor Right or Left rear piping8047065 6591.545Latch65Right rear pipingFor Right or Left piping6015 60The screw of the lidis tightened securely.LatchWhen drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use pipe hole sleeve sold separately.Indoor side65Outdoor sideDrill a hole with whole core drill.Indoor unit piping directionDrainageArrange the drain hose in a downward angleAvoid the following drain piping.Higher than specified The drain hosetip is in water5b Topb cThicknese of the wall + 1.5cmIn case of rear piping draw out, cut off the lowerand the right side portions of the sleeve collar.WavyaTurn totightenIndoor side Outdoor side Installed stateCAUTION Go through all installation steps and check if thedralnage is all right. Otherwise water leak may occur.Odor fromthe gutterThe gap to the ground is The drain hose5 cm or lesstip is in the gutter5 cm minimumfrom the wall15 cm or below from the floorRight/Left pipingWireless remote control76.355157.27 cm minimum from the ceilingWood screwsCAUTIONCompletely seal the hole onthe wall with putty. Otherwise,furniture, or other, may bewetted by leaked water ordewing.Installing the support of pipingFor Right or Left bottom pipingLeft bottom piping85.3 22.760100Right bottom pipingRemote control holderIn case of piping in the right rear directionTaping of the exteriorIndoor sideputtyTape only the portionthat goes through thewall.Always tape the wiringwith the piping.Sufficient care must be taken not to damagethe panel when connecting pipes.from the wallOutdoor sidePour water to the drain pan located under the heat exchanger, and ensure that the water is discharged outdoor.When the extended drain hose is indoor, securely insulate it with a heat insulator available in the market.Installation board5 cm +Service space (30cm)Sleeve(sold separately)puttyCAUTIONBe careful not tostress the connectingrefrigerant pipse. (Donot pull with a force oflarger than 5 kgf.) Ifimproperly installed,it may cause abnormalnoise and vibration.