11.07.2015 Views

BrightStor CA-1 Tape Management - SupportConnect

BrightStor CA-1 Tape Management - SupportConnect

BrightStor CA-1 Tape Management - SupportConnect

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7. Run any IVP jobs to test tape processing and batch/online TMC inquiry. TMSCKLVL can be used toverify the maintenance level of the active SVC module TMS00SVC. All csects updated by theenhancement should show eyecatcher PFFC044, unless remodified by subsequent maintenance.TMSCKLVL also displays the level of the TMSTMVT module which was loaded by <strong>CA</strong>S9 after the lastIPL. LEVEL = TVT5200 indicates the old level, LEVEL = TVT5201 indicates the PFFC044 level ofTMSTMVT is active.8. If all results are OK, resume tape processing.If a backout of the maintenance should be required, restore the APAR from your target library andrepeat steps 3 through 7 accordingly.Once all systems sharing the TMC have been upgraded and are running at the new level withoutproblems, the TMC can be reblocked if desired.*** The following steps are required to reblock the TMC: ***9. Run TMSCKLVL on all systems to verify that the active TMSTMVT and TMS00SVC modules show thecorrect maintenance level.10. Stop tape processing on all systems sharing the TMC.11. If subtask DBS is active in the CTS address space, issue the following CTS command to unallocate theTMC:MSG DBS,'RELEASE TMC'12. Back up the TMC using TMSCOPY.13. Allocate a new TMC data set on a shared device which is accessible from all systems. SpecifyDSORG=PSU in the DCB parameter, unless the volume is SMS controlled. Provide the desired blocksize:DCB=(DSORG=PSU,RECFM=FB,LRECL=340,BLKSIZE=n*340)14. Execute IEBGENER to copy the production TMC into the blocked TMC.15. Rename the production TMC to an alternate name, and catalog the blocked TMC under the productionname on all CPUs.16. Run TMSINIT to restart <strong>CA</strong>-1 on all systems.17. Run any IVP jobs to test tape processing and batch/online TMC inquiry. Ensure all systems are pointingto the same TMC data set and can access it properly. If any problems occur, rename the blocked TMCto an alternate name, and catalog the original TMC under the production name on all systems. Go backto step 16 to re-activate the original, unblocked TMC.18. If all results are OK, resume tape processing.19. If the DBS subtask is active in the CTS address space, issue the following command to re-allocate theTMC:MSG DBS,'OBTAIN TMC'If you need to backout the change, perform the same steps 10 through 19 accordingly to unblock your TMC.PDC#: QI12531

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!