11.07.2015 Views

Planck Pre-Launch Status Papers - APC - Université Paris Diderot ...

Planck Pre-Launch Status Papers - APC - Université Paris Diderot ...

Planck Pre-Launch Status Papers - APC - Université Paris Diderot ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A. Mennella et al.: LFI calibration and expected performanceFig. 4. Amplitude spectral densities of unswitched and differenced data streams. The pseudo-correlation differential design reduces the 1/ f kneefrequency by three orders of magnitude. The white noise level scales almost perfectly with K.Table 5. White noise sensitivities per radiometer in µK · s 1/2 .From uncalib. noiseM-0 S-170 GHzLFI18 468 468LFI19 546 522LFI20 574 593LFI21 424 530LFI22 454 463LFI23 502 63544 GHzLFI24 372 447LFI25 501 492LFI26 398 39230 GHzLFI27 241 288LFI28 315 251From radiom. equationM-0 S-170 GHzLFI18 450 450LFI19 482 466LFI20 498 511LFI21 381 496LFI22 428 410LFI23 453 41944 GHzLFI24 404 407LFI25 451 462LFI26 455 42830 GHzLFI27 311 320LFI28 305 268Notes. Sensitivity values have been extrapolated at CMB input usingthe two methods outlined in the text and detailed in Appendix D.Fig. 5. Thermal instabilities during the long duration acquisition. Top:drift in the reference load temperature caused by leakage in the gas capthermal switch. The drop towards the end of the test coincides with refillof the thermal switch. Bottom: 24-h back-end temperature fluctuation.input using the radiometeric response equation, Eq. (2). The detailsof the extrapolation are given in Appendix D.Table 5 indicates the sensitivity per radiometer estimatedaccording to the two procedures. The sensitivity per radiometerwas obtained using a weighted noise average from the twodetectors of each radiometer (see Appendix E). Because radiometersLFI18M-0 and LFI24M-0 were not working duringthe tests, we estimated the sensitivity per frequency channel byconsidering the white noise sensitivity of LFI24M-0,whichwaslater repaired, measured during receiver-level tests, while forLFI18M-0,whichwaslaterreplacedbyaspareunit,weassumedthe same sensitivity as for LFI18S-1. Furtherdetailsaboutthewhite noise sensitivity of individual detectors are reported inMeinhold et al. (2009).We provide in Table 6 the sensitivity per frequency channelestimated using the two procedures and compared with the LFIrequirement.5.2.4. 1/f noise parametersThe 1/ f noise properties of the LFI differenced data were determinedmore accurately during instrument-level than receiverleveltests for two reasons: (i) the test performed in this phasewas the longest of all the test campaign; and (ii) because of thePage 7 of 16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!