Short Form Catalogue<strong>SELCO</strong> T-<strong>Line</strong><strong>Generator</strong> <strong>Control</strong>,<strong>Protection</strong> <strong>and</strong> <strong>Monitoring</strong>SYNCHROSCOPETOOSLOWSYNCTOOFASTBUSGEN


Selco T-<strong>Line</strong>The Selco T-line offers a complete range of system components for generator control,protection <strong>and</strong> power monitoring.The units are for DIN rail mounting or screw mounting in switchboards. Since theunits are working on identical principles <strong>and</strong> have similar design <strong>and</strong> adjustmentschemes, they are easily installed or replaced. All units are available in a numberof versions varying in supply voltage <strong>and</strong> other functions, hence meeting specificcustomer requirements to a large extend.Synchronizing <strong>and</strong>load/power controlThe <strong>SELCO</strong> T-<strong>Line</strong> range includes various Auto Synchronizers <strong>and</strong> Load Sharers forload/power control. The Auto Synchronizers perform automatic synchronization ofincoming generators in a minimum of time. The Load Sharers provide automatic loadsharing <strong>and</strong> system frequency control for generators running in parallel.Two solutions are available: One for synchronizing <strong>and</strong> load sharing on generatorswith conventional governors (<strong>and</strong> electronic speed controllers via an intermediatemotorized potentiometer). The other for connection directly to all types of electronicspeed controllers. For synchronizing <strong>SELCO</strong> also supplies Synchroscopes for illuminatedindication of the phase difference.Also available is a VAr Load Sharer for automatic load sharing of the reactive power orfor power factor control on generators running in parallel with the grid (utility).Cogeneration ApplicationT4500GridM8100T4500B9300T4500BusbarT4800T4800GG! „We have used <strong>SELCO</strong> for a number of yearsnow, <strong>and</strong> frequently use their products as afirst choice solution for our various controlapplications. We find the efficiency of theirservice a great help during „break-downsite“ situations.“Lee Dainty, Purchaser,Twyer Instrumentation <strong>Control</strong> & Switchgear,United KingdomSynchronizing Parallel Running <strong>Generator</strong>s to the Grid or a Shaft <strong>Generator</strong>


Complete <strong>Protection</strong> of <strong>Generator</strong>sT2700Overload RelayP (kW)T2500 Overcurrent<strong>and</strong> Short Circuit RelayThe relay detects the highest of the 3 inputcurrents <strong>and</strong>, when the preset valuesare exceeded the output relays will beactivated after preset time delays.T2500 3 Phase Overcurrent<strong>and</strong> Short Circuit RelayI x Cos ffII x Sin fQ (kVAr)T2100 ExcitationLoss Relay<strong>Generator</strong>’s PermittedArea of OperationT2000 ReversePower RelayThis figure illustrates the complete protection of a generator. The green shaded area illustratesthe permitted area of operation for a generator. This information is normally supplied by thegenerator manufacturer.The vertical axis represents the active power, <strong>and</strong> the horizontal axis represents the reactivepower. The active power is represented by I x Cos Φ. The T2700 Power Relay measures I x CosΦ, <strong>and</strong> when it becomes too high, the relay will trip, indicated by the upper horizontal red line.The T2500 is intended for protectionof generators, power transmissions<strong>and</strong> consumer supply against thermaldamage <strong>and</strong> faults caused by high currents,with consequent tripping of thesystem breaker.The relay detects the highest of the 3 inputcurrents <strong>and</strong>, when the preset valuesare exceeded, the output relay will beactivated after preset time delays.T2600 Dual Current RelayThe Reverse Power relay measures -I x Cos Φ, representing the active power in the negativedirection, <strong>and</strong> it will trip for reverse power. The T2100 Excitation Loss Relay measures -I x Sin Φ,representing the reactive power in negative direction, <strong>and</strong> it will trip when exceeding the levelrepresented by the red vertical line.The T2500 Overcurrent <strong>and</strong> Short Circuit Relay measures the magnitude of the current <strong>and</strong> thusprotects against current levels outside the area of the red circle.T2300 3 Phase Short CircuitRelayThe T2300 is intended for protectionof generators, power transmissions<strong>and</strong> consumer supply against damagecaused from short circuit by tripping thecircuit breaker.The relay detects the highest of the 3input currents <strong>and</strong>, when the presetvalue is exceeded, an output relay willbe activated instantly (100 msec.) or aftera preset time delay.T2400 3 Phase DualOvercurrent RelayThe T2400 furnishes 2 combined overcurrentrelays, intended for protection ormonitoring of generators, power transmissions<strong>and</strong> consumer supply.A typical generatorapplication is to letone of the overcurrent functions trip thegenerator breaker <strong>and</strong> to let the otherovercurrent function trip a nonessentialservice. Both overcurrent functions couldbe used to trip 2 levels of nonessentialloads. (Widely used in marine applikations)The T2600 determines load dependingstart <strong>and</strong> stop levels of a st<strong>and</strong>by dieselgenerator. When load increases on therunning diesel generators more than e.g.90%, adjustable, for a preset time, a startsignal to call for the st<strong>and</strong>by diesel generatorwill be provided. If the load decreasesbelow e.g. 45%, adjustable, for apreset time, a stop signal will be providedto stop the st<strong>and</strong>by diesel generator.The T2600 can serve an installation withup to 3 diesel generators. With an extensionunit additional generators can beserved.


T2700 Power RelayT3000 Frequency RelayT3200 Insulation MonitorφThe T2700 is intended for detection ofpower level for protection, control <strong>and</strong>monitoring purposes. The relay detectsthe magnitude of the power <strong>and</strong>, whenthe preset value is exceeded, an outputrelay will be activated after a preset timedelay.T2800 Overcurrentor Earth Fault RelayThe T3000 is intended for effectivefrequency monitoring on generators,busbars or other distribution systems.The relay contains the functions “underfrequency” <strong>and</strong> “over frequency”, timedelayed, <strong>and</strong> 2 individual output relays,one relay for each function.T3100 <strong>and</strong> T3300 VoltageRelaysThe T3200 is intended for continuousinsulation monitoring on 3 phase insulatednetworks on board ships. The relaycontinuously monitors two systems galvanicallyseparated from each other, e.g.the busbar <strong>and</strong> the lighting system ortwo busbar systems.The unit features two output relays foralarm purposes <strong>and</strong> two analog outputsfor instrument readings.T3500 Frequency DeviationRelayThe T2800 has a broad application as anearth fault or a single phase overcurrentdetection relay. It has a wide setting rangefor protection, control or monitoring.The relay detects the magnitude of thecurrent <strong>and</strong>, when the preset value isexceeded, an output relay will beactivated after a preset time delay.T2900 3 Phase DifferentialCurrent RelayThe T3100 <strong>and</strong> T3300 are intended for effectivevoltage monitoring on generators,busbars or other distribution systems. Therelays contain the functions “under voltage”<strong>and</strong> “over voltage”, time delayed,<strong>and</strong> 2 individual output relays, one foreach function.T3100 is for monitoring on one phase<strong>and</strong> T3300 is for 3 phase monitoring.T8400 Blackout LimiterRate of change of frequency (ROCOF)relay, df/dt relay. The T3500 will monitorthe frequency of the connectedbusbar. In case there is a rapid changeof frequency, the relay will trip.11 12 13 14 15 16 17 18 19 20POWERRELAY3-PHASEDIFF. CURRENTRELAY T29000.160.04xI N0.280.414SEC.710171819202122232425262728293031321 2 3 4 5 6 7 8 9 1012345678910111213141516The T2900 3 Phase Differential Relayis intended as a protection relay forgenerators, power transmissions <strong>and</strong>consumer’s supply by tripping themain circuit breaker.The T2900 measures the differentialcurrent of each of the 3 phases.The relay detects the highest of the 3input currents <strong>and</strong>, when the presetvalues are exceeded, the output relaywill be activated after preset time delays.The T8400 enables fast clearing of ablackout. If a blackout occurs, the firstgenerator to have more than 90 %voltage will make the generator breakerclose. It is possible to monitor up to 4generators with 1 unit, <strong>and</strong> up to 8 generatorswith 2 units.


We are <strong>SELCO</strong>Since the origin in 1960, <strong>SELCO</strong> technology has provided the electricalpower generation market with high class equipment, living upto the major international st<strong>and</strong>ards.<strong>Generator</strong> <strong>Control</strong>, <strong>Protection</strong> & <strong>Monitoring</strong>– <strong>Generator</strong> protection:Short circuit, overcurrent, reverse power, excitation loss,engine protection.– <strong>Generator</strong> controls:Synchronizing, frequency control, active <strong>and</strong> reactive loadsharing, load control, power management, engine control.– <strong>Generator</strong> monitoring:Voltage, frequency, power, insulation.The <strong>SELCO</strong> equipment has been thoroughly tested bycertified laboratories with regard to high vibration levels,heat, cold, humidity, salt mist, EMC emission <strong>and</strong> immunityas well as other parameters.<strong>SELCO</strong> products are in accordance with all significantinternational st<strong>and</strong>ards <strong>and</strong> have been approved <strong>and</strong>certified by the major marine classification societies.<strong>SELCO</strong> Worldwide<strong>SELCO</strong> Denmark<strong>SELCO</strong> subsidiary<strong>SELCO</strong> representationMain Office:<strong>SELCO</strong> A/SBetonvej 10DK- 4000 RoskildeDenmarkPhone: + 45 - 70 26 11 22Fax: + 45 - 70 26 25 22e-mail: selco.dk@selco.comwww.selco.comQ1006-72E