11.07.2015 Views

OptiMelt Automated Melting Point System - Stanford Research ...

OptiMelt Automated Melting Point System - Stanford Research ...

OptiMelt Automated Melting Point System - Stanford Research ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

82 Pharmacopeia vs. Thermodynamic <strong>Melting</strong> <strong>Point</strong>s Appendix A• Calculation of your sample’s Thermodynamic Correction Factor, ThermoCF, isrecommended when accuracy is required. See the next section for details.Calculation of Thermodynamic Correction FactorThe Thermodynamic Correction Factor, ThermoCF, is compound specific and dependson several factors:• Specific heat of fusion of the sample• Amount of sample• thermal conductivity of the sample• thermal conductivity of the glass capillary• sample preparation method• geometry of the ovenExperimental measurements have shown that in most cases a good approximation to theThermodynamic Correction Factor, ThermoCF, for the SRS <strong>OptiMelt</strong> is a value of ~1.0,when r is expressed in standard units of [°C/min]. However, empirical calculation of theThermodynamic Correction Factor is recommended when more accurate results arerequired for a specific compound.A step-by-step calculation procedure is described below:Step 1Perform complete pharmacopeia melting point determinations on your sample at sixdifferent temperature ramping rates: 0.1, 0.2, 0.5, 1, 2 and 5 °C/min.• Three samples are analyzed simultaneously for each ramping rate: Load threecapillaries with a 2–3 mm column of sample, and insert the tubes into the threeadjacent sample slots of the <strong>OptiMelt</strong> oven.• To increase the accuracy of results, load the capillaries using the exact samegrinding, loading and packing techniques used for routine melting pointdeterminations. Match all sample heights very carefully.• For each ramping rate, average the detected “clear points” (according topharmacopeia) for the three samples to obtain the recorded value.• To increase the accuracy of results, use manual (automatic) clear point readings ifmanual (automatic) determinations are routinely performed in the lab.Step 2Plot the resulting clear point records versus the square root of their correspondingtemperature ramping rate (MP pharma vs r 1/2 ) – a linear dependence should be observed.Calculate the slope of the straight line, and program the result into the ThermodynamicCorrection Factor, ThermoCF, of your <strong>OptiMelt</strong>.<strong>OptiMelt</strong> <strong>Automated</strong> <strong>Melting</strong> <strong>Point</strong> <strong>System</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!