11.07.2015 Views

OptiMelt Automated Melting Point System - Stanford Research ...

OptiMelt Automated Melting Point System - Stanford Research ...

OptiMelt Automated Melting Point System - Stanford Research ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix D <strong>OptiMelt</strong> Remote Programming 105<strong>Automated</strong> Determination CommandsAMDE (?) {i}OPTP (?) {n}CPTP (?) {n}SPTP (?) {n}AOPT? {i}ACPT? {i}DetectionThe AMDE command sets (queries) the <strong>Melting</strong> <strong>Point</strong> Determination Mode toCamera (i=1) or Visual Only (i=0).ExampleAMDE?AMDE 1Returns the determination mode (camera or visual).Sets the determination to camera (automatic).Onset <strong>Point</strong> ThresholdThe OPTP command sets (queries) the Onset <strong>Point</strong> Threshold percentage. Theinteger n is the percentage from 0 to 100.ExampleOPTP? Returns the onset point threshold percentage.OPTP 70 Sets the onset point threshold to 70%.Clear <strong>Point</strong> ThreholdThe CPTP command sets (queries) the Clear <strong>Point</strong> Threshold percentage. Theinteger n is the percentage from 0 to 100.ExampleCPTP? Returns the clear point threshold percentage.CPTP 10 Sets the clear point threshold to 10%.Single <strong>Melting</strong> <strong>Point</strong> ThresholdThe SPTP command sets (queries) the Single <strong>Melting</strong> <strong>Point</strong> Thresholdpercentage. The integer n is the percentage from 0 to 100.ExampleSPTP? Returns the single melting point threshold percentage.SPTP 50 Sets the single melting point threshold to 50%.Read the Onset <strong>Point</strong>The AOPT? {i} query returns the onset point from the most recent determinationin degrees C. The index I is 0, 1 or 2 for the left, center or right capillary. Thevalue returned is in SRS internal integer format, with a conversion factor of4096. To obtain the temperature value, divide the reading by 4096. If a reading of-819200 is returned, then no onset point was determined.ExampleAOPT? 1 Returns 966656 for the center capillary. Divide by 4046 toobtain a temperature reading of 236 degrees C.Read the Clear <strong>Point</strong>The ACPT? {i} query returns the clear point from the most recent determinationin degrees C. The index I is 0, 1 or 2 for the left, center or right capillary. Thevalue returned is in SRS internal integer format, with a conversion factor of<strong>OptiMelt</strong> <strong>Automated</strong> <strong>Melting</strong> <strong>Point</strong> <strong>System</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!