OptiMelt Automated Melting Point System - Stanford Research ...
OptiMelt Automated Melting Point System - Stanford Research ...
OptiMelt Automated Melting Point System - Stanford Research ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Appendix D <strong>OptiMelt</strong> Remote Programming 105<strong>Automated</strong> Determination CommandsAMDE (?) {i}OPTP (?) {n}CPTP (?) {n}SPTP (?) {n}AOPT? {i}ACPT? {i}DetectionThe AMDE command sets (queries) the <strong>Melting</strong> <strong>Point</strong> Determination Mode toCamera (i=1) or Visual Only (i=0).ExampleAMDE?AMDE 1Returns the determination mode (camera or visual).Sets the determination to camera (automatic).Onset <strong>Point</strong> ThresholdThe OPTP command sets (queries) the Onset <strong>Point</strong> Threshold percentage. Theinteger n is the percentage from 0 to 100.ExampleOPTP? Returns the onset point threshold percentage.OPTP 70 Sets the onset point threshold to 70%.Clear <strong>Point</strong> ThreholdThe CPTP command sets (queries) the Clear <strong>Point</strong> Threshold percentage. Theinteger n is the percentage from 0 to 100.ExampleCPTP? Returns the clear point threshold percentage.CPTP 10 Sets the clear point threshold to 10%.Single <strong>Melting</strong> <strong>Point</strong> ThresholdThe SPTP command sets (queries) the Single <strong>Melting</strong> <strong>Point</strong> Thresholdpercentage. The integer n is the percentage from 0 to 100.ExampleSPTP? Returns the single melting point threshold percentage.SPTP 50 Sets the single melting point threshold to 50%.Read the Onset <strong>Point</strong>The AOPT? {i} query returns the onset point from the most recent determinationin degrees C. The index I is 0, 1 or 2 for the left, center or right capillary. Thevalue returned is in SRS internal integer format, with a conversion factor of4096. To obtain the temperature value, divide the reading by 4096. If a reading of-819200 is returned, then no onset point was determined.ExampleAOPT? 1 Returns 966656 for the center capillary. Divide by 4046 toobtain a temperature reading of 236 degrees C.Read the Clear <strong>Point</strong>The ACPT? {i} query returns the clear point from the most recent determinationin degrees C. The index I is 0, 1 or 2 for the left, center or right capillary. Thevalue returned is in SRS internal integer format, with a conversion factor of<strong>OptiMelt</strong> <strong>Automated</strong> <strong>Melting</strong> <strong>Point</strong> <strong>System</strong>