GASBOY Series 9820Q023866 Wiring Diagram, Models: 9822Q, 9823QDomestic 115/230 VACNOTES:1. All wiring and conduit runs must conform with all building/fire codes, all Federal, State, andLocal codes, National Electrical Code, (NFPA 70), NFPA 30, and Automotive and MarineService Station Code (NFPA 30A) codes and regulations. Canadian users must also complywith the Canadian Electrical Code.2. Pump motor can be wired as 230 VAC to reduce current draw. See breakaway view of 230VAC PUMP MOTOR. All other wiring should remain the same except for the addition ofthe L2 (requires 230 VAC breaker for control). If connected to equipment requiring controlof the authorization input, the Phase 2 Feed should be switched through a separate relay toprevent false triggering of the authorization signal.3. If the PUMP MOTOR line is controlled by a fuel management system using solid staterelays, a resistor assembly must be installed between the Pump Motor Feed line and Neutral toprevent false triggering of the authorization input. The resistor assembly is 8.2K OHM, 10Watt (P/N C05818) for 115/230 VAC domestic and 30K OHM, 10 Watt (P/N C06683) for230 VAC international wiring.4. SLOW FLOW and FAST FLOW lines are typically used when connecting to an optionalvalve. Each of these lines is capable of supplying 300 mA AC maximum (170 mA ACmaximum if already connected to the optional valve). These lines must not be shorted toany conduit or chassis metal, mis-wired, or connected to any equipment requiring morethan stated maximum allowable current. If these restrictions are not followed, damageto the CPU PCB will occur.5. Use the wire size chart listed when determining the wire size for the control wiring.22 MDE-4339 9820Q ASTRA Installation/Operation • July 2004
Wiring023866 Wiring Diagram, Models: 9822Q, 9823QDomestic 115/230 VACWARNING:Failure to follow the correct wiring diagram and all the listed notes and precautions may result indamage to the CPU PCB.MDE-4339 9820Q ASTRA Installation/Operation • July 2004 23
- Page 1 and 2: Series 9820Q ASTRAInstallation/Oper
- Page 4 and 5: FCC InformationThe US Federal Commu
- Page 6 and 7: GASBOY Series 9820Q023866 Wiring Di
- Page 8 and 9: GASBOY Series 9820QOptional Feature
- Page 12 and 13: GASBOY Series 9820QTypical Installa
- Page 14 and 15: GASBOY Series 9820Q011930 Base Layo
- Page 16 and 17: GASBOY Series 9820Q011885 Base Layo
- Page 18 and 19: GASBOY Series 9820Q12 MDE-4339 9820
- Page 20 and 21: GASBOY Series 9820QNeutral FeedThe
- Page 22 and 23: GASBOY Series 9820Q16 MDE-4339 9820
- Page 24 and 25: GASBOY Series 9820QGroundTo ensure
- Page 26 and 27: GASBOY Series 9820QConduitAll wirin
- Page 30 and 31: GASBOY Series 9820Q023867 Wiring Di
- Page 32 and 33: GASBOY Series 9820Q26 MDE-4339 9820
- Page 34 and 35: GASBOY Series 9820QElectronic Compo
- Page 36 and 37: GASBOY Series 9820QSW1-6 Authorizat
- Page 38 and 39: GASBOY Series 9820QATC Information
- Page 40 and 41: GASBOY Series 9820QTo view the pump
- Page 42 and 43: Start-up and Test6. Start-Up and Te
- Page 44 and 45: GASBOY Series 9820Q1. Check meter r
- Page 46 and 47: GASBOY Series 9820QClean the Dial F
GASBOY <strong>Series</strong> <strong>9820Q</strong>023866 Wiring Diagram, Models: 9822Q, 9823QDomestic 115/230 VACNOTES:1. All wiring and conduit runs must conform with all building/fire codes, all Federal, State, andLocal codes, National Electrical Code, (NFPA 70), NFPA 30, and Automotive and MarineService Station Code (NFPA 30A) codes and regulations. Canadian users must also complywith the Canadian Electrical Code.2. Pump motor can be wired as 230 VAC to reduce current draw. See breakaway view of 230VAC PUMP MOTOR. All other wiring should remain the same except for the addition ofthe L2 (requires 230 VAC breaker for control). If connected to equipment requiring controlof the authorization input, the Phase 2 Feed should be switched through a separate relay toprevent false triggering of the authorization signal.3. If the PUMP MOTOR line is controlled by a fuel management system using solid staterelays, a resistor assembly must be installed between the Pump Motor Feed line and Neutral toprevent false triggering of the authorization input. The resistor assembly is 8.2K OHM, 10Watt (P/N C05818) for 115/230 VAC domestic and 30K OHM, 10 Watt (P/N C06683) for230 VAC international wiring.4. SLOW FLOW and FAST FLOW lines are typically used when connecting to an optionalvalve. Each of these lines is capable of supplying 300 mA AC maximum (170 mA ACmaximum if already connected to the optional valve). These lines must not be shorted toany conduit or chassis metal, mis-wired, or connected to any equipment requiring morethan stated maximum allowable current. If these restrictions are not followed, damageto the CPU PCB will occur.5. Use the wire size chart listed when determining the wire size for the control wiring.22 MDE-4339 <strong>9820Q</strong> <strong>ASTRA</strong> <strong>Installation</strong>/<strong>Operation</strong> • July 2004