Wiring4. Wiring☎Customers and installers having any questions pertaining to the installation should contact theirGASBOY distributor.Wiring PrecautionsThe quality of the electrical installation is a major factor in maintaining proper safety levels andproviding trouble-free operation of your GASBOY pump. To assure a quality installation, followthese rules:1. All wiring must be installed to conform with all building/fire codes, all Federal, State, andLocal codes, National Electrical Code, (NFPA 70), NFPA 30, and Automotive and MarineService Station Code (NFPA 30A) codes and regulations. Canadian users must also complywith the Canadian Electrical Code.2. Use only threaded, rigid, metal conduit.3. Use only UL-Labeled insulated gasoline- and oil-resistant stranded copper wiring of theproper size.4. Wire connections should be tightly spliced and secured with a wire nut; close off the open endof the wire nut with electrical tape.5. The line to the motor should be on a separate circuit and installed on a 20 to 30 AMP breakerdepending on the motor size and/or the voltage setting.6. Install an emergency power cutoff. In addition to circuit breaker requirements of NFPA 70and NFPA 30A, a single control which simultaneously removes AC power from all sitedispensing equipment is recommended. This control must be readily accessible, clearlylabeled, and in accordance with all local codes.In a fuel management system application, the EMERGENCY STOP and STOP keys on theconsole and/or the optional EMERGENCY STOP button on the Island Card Reader do notremove AC power from equipment and under certain conditions, will not stop product flow.In order to provide the highest level of safety to you, your employees, and customers, werecommend that all employees be trained as to the location and procedure for turning offpower to the entire system.WARNING:To reduce the risk of electrical shock when servicing, turn off and lock out all power to the pump.AVERTISSEMENTPour réduire le risque de choc électrique lors de l'entretien/révision, coupez totalement le courant à lapompe/distributeur.Have the pump installed by a competent installer/electrician.MDE-4339 9820Q ASTRA Installation/Operation • July 2004 17
- Page 1 and 2: Series 9820Q ASTRAInstallation/Oper
- Page 4 and 5: FCC InformationThe US Federal Commu
- Page 6 and 7: GASBOY Series 9820Q023866 Wiring Di
- Page 8 and 9: GASBOY Series 9820QOptional Feature
- Page 12 and 13: GASBOY Series 9820QTypical Installa
- Page 14 and 15: GASBOY Series 9820Q011930 Base Layo
- Page 16 and 17: GASBOY Series 9820Q011885 Base Layo
- Page 18 and 19: GASBOY Series 9820Q12 MDE-4339 9820
- Page 20 and 21: GASBOY Series 9820QNeutral FeedThe
- Page 24 and 25: GASBOY Series 9820QGroundTo ensure
- Page 26 and 27: GASBOY Series 9820QConduitAll wirin
- Page 28 and 29: GASBOY Series 9820Q023866 Wiring Di
- Page 30 and 31: GASBOY Series 9820Q023867 Wiring Di
- Page 32 and 33: GASBOY Series 9820Q26 MDE-4339 9820
- Page 34 and 35: GASBOY Series 9820QElectronic Compo
- Page 36 and 37: GASBOY Series 9820QSW1-6 Authorizat
- Page 38 and 39: GASBOY Series 9820QATC Information
- Page 40 and 41: GASBOY Series 9820QTo view the pump
- Page 42 and 43: Start-up and Test6. Start-Up and Te
- Page 44 and 45: GASBOY Series 9820Q1. Check meter r
- Page 46 and 47: GASBOY Series 9820QClean the Dial F
GASBOY <strong>Series</strong> <strong>9820Q</strong>16 MDE-4339 <strong>9820Q</strong> <strong>ASTRA</strong> <strong>Installation</strong>/<strong>Operation</strong> • July 2004