GASBOY Series 9820QNeutral FeedThe Neutral Feed is the AC current return line back to the breaker panel for all attached devices(pump motor, solenoid valves).Slow Flow (Reset Complete/Switch Detect)The Slow Flow line is a 115VAC (230VAC Int'l) output which is used to control the slow flowvalve of the optional solenoid valve. This line also indicates when the reset process is completeand the unit is ready to dispense product. This line can be used in conjunction with a fuelmanagement system (for systems other than the Gasboy CFN Series systems).This line is capable of supplying 300 mA AC maximum (170 mA maximum if already connectedto the optional valve). This line must not be shorted to any conduit or chassis metal, mis-wired, orbe connected to any equipment requiring more than stated maximum allowable current. If theserestrictions are not followed, damage to the CPU PCB will occur.Fast FlowThe Fast Flow line is a 115VAC (230VAC Int'l) output which is used to control the fast flow valveof the optional solenoid valve.This line is capable of supplying 300 mA AC maximum (170 mA maximum if already connectedto the optional valve). This line must not be shorted to any conduit or chassis metal, mis-wired, orbe connected to any equipment requiring more than stated maximum allowable current. If theserestrictions are not followed, damage to the CPU PCB will occur.Phase 2 FeedThe Phase 2 Feed is a hot feed which is the opposite phase of the pump motor feed. This line andthe pump motor feed are used for 230VAC motor applications. If connected to equipmentrequiring control of the authorization input, the Phase 2 Feed should be switched through aseparate relay to prevent false triggering of the authorization signal.PulserThese lines are used to connect the pulser, mounted in the pumping unit, to the electronics in theregister assembly. These are DC voltage lines and provide the information necessary for theregister assembly to monitor the quantity of product dispensed. These lines are for internal useonly and must not be used for the pulse output (for external monitoring of the unit). Use theoptional Pulse Output interface if external pulses are required.Pulse OutputThis option provides a DC pulser output to indicate the quantity dispensed. This is an opencollector output. This output can sink up to 150 milliamps DC at voltages up to 24 VDC. Thepulse rate can be configured by a sealable DIP switch for rates of 1, 10, 100, 250, 500, or 1000pulses per gallon or 1, 10, 100 or 250 pulses per liter. This output should only be used whenmonitoring of the unit's operation is desired.14 MDE-4339 9820Q ASTRA Installation/Operation • July 2004
Control LinesRS-485When the dispensing unit includes the optional RS-485 interface, RS-485 lines are provided. Thisinterface allows the user to connect a GASBOY CFN Series System or TopKAT system directly tothe Series 9820Q dispensing unit.MDE-4339 9820Q ASTRA Installation/Operation • July 2004 15
- Page 1 and 2: Series 9820Q ASTRAInstallation/Oper
- Page 4 and 5: FCC InformationThe US Federal Commu
- Page 6 and 7: GASBOY Series 9820Q023866 Wiring Di
- Page 8 and 9: GASBOY Series 9820QOptional Feature
- Page 12 and 13: GASBOY Series 9820QTypical Installa
- Page 14 and 15: GASBOY Series 9820Q011930 Base Layo
- Page 16 and 17: GASBOY Series 9820Q011885 Base Layo
- Page 18 and 19: GASBOY Series 9820Q12 MDE-4339 9820
- Page 22 and 23: GASBOY Series 9820Q16 MDE-4339 9820
- Page 24 and 25: GASBOY Series 9820QGroundTo ensure
- Page 26 and 27: GASBOY Series 9820QConduitAll wirin
- Page 28 and 29: GASBOY Series 9820Q023866 Wiring Di
- Page 30 and 31: GASBOY Series 9820Q023867 Wiring Di
- Page 32 and 33: GASBOY Series 9820Q26 MDE-4339 9820
- Page 34 and 35: GASBOY Series 9820QElectronic Compo
- Page 36 and 37: GASBOY Series 9820QSW1-6 Authorizat
- Page 38 and 39: GASBOY Series 9820QATC Information
- Page 40 and 41: GASBOY Series 9820QTo view the pump
- Page 42 and 43: Start-up and Test6. Start-Up and Te
- Page 44 and 45: GASBOY Series 9820Q1. Check meter r
- Page 46 and 47: GASBOY Series 9820QClean the Dial F
GASBOY <strong>Series</strong> <strong>9820Q</strong>Neutral FeedThe Neutral Feed is the AC current return line back to the breaker panel for all attached devices(pump motor, solenoid valves).Slow Flow (Reset Complete/Switch Detect)The Slow Flow line is a 115VAC (230VAC Int'l) output which is used to control the slow flowvalve of the optional solenoid valve. This line also indicates when the reset process is completeand the unit is ready to dispense product. This line can be used in conjunction with a fuelmanagement system (for systems other than the <strong>Gasboy</strong> CFN <strong>Series</strong> systems).This line is capable of supplying 300 mA AC maximum (170 mA maximum if already connectedto the optional valve). This line must not be shorted to any conduit or chassis metal, mis-wired, orbe connected to any equipment requiring more than stated maximum allowable current. If theserestrictions are not followed, damage to the CPU PCB will occur.Fast FlowThe Fast Flow line is a 115VAC (230VAC Int'l) output which is used to control the fast flow valveof the optional solenoid valve.This line is capable of supplying 300 mA AC maximum (170 mA maximum if already connectedto the optional valve). This line must not be shorted to any conduit or chassis metal, mis-wired, orbe connected to any equipment requiring more than stated maximum allowable current. If theserestrictions are not followed, damage to the CPU PCB will occur.Phase 2 FeedThe Phase 2 Feed is a hot feed which is the opposite phase of the pump motor feed. This line andthe pump motor feed are used for 230VAC motor applications. If connected to equipmentrequiring control of the authorization input, the Phase 2 Feed should be switched through aseparate relay to prevent false triggering of the authorization signal.PulserThese lines are used to connect the pulser, mounted in the pumping unit, to the electronics in theregister assembly. These are DC voltage lines and provide the information necessary for theregister assembly to monitor the quantity of product dispensed. These lines are for internal useonly and must not be used for the pulse output (for external monitoring of the unit). Use theoptional Pulse Output interface if external pulses are required.Pulse OutputThis option provides a DC pulser output to indicate the quantity dispensed. This is an opencollector output. This output can sink up to 150 milliamps DC at voltages up to 24 VDC. Thepulse rate can be configured by a sealable DIP switch for rates of 1, 10, 100, 250, 500, or 1000pulses per gallon or 1, 10, 100 or 250 pulses per liter. This output should only be used whenmonitoring of the unit's operation is desired.14 MDE-4339 <strong>9820Q</strong> <strong>ASTRA</strong> <strong>Installation</strong>/<strong>Operation</strong> • July 2004