Depliant - Tecnoalarm

Depliant - Tecnoalarm Depliant - Tecnoalarm

tecnoalarm.com
from tecnoalarm.com More from this publisher
11.07.2015 Views

<strong>Tecnoalarm</strong>TechnologyThe <strong>Tecnoalarm</strong> systems which are equipped with the(Remote Sensitivity Control) technology communicate withthe monitoring station and transmit specific and detailedinformation. The <strong>Tecnoalarm</strong> monitoring station can programand constantly monitor the system from a distance and, usingsophisticated diagnostic tools, verify the smooth functioningand obtain the necessary information to maintain and improveits performance.SystemProgrammingConfigurationProgramming of the system’s functioning parameters can be madelocally or remotely, via telephone line, using the <strong>Tecnoalarm</strong> software.The software provides numerous programming tools which permitcustomization of the installation selecting the most appropriate amongthe options available.ZoneZonesConfigurationSystem configuration is entirely modular thanks to the input expansion modules.The 2 conventional and the 6 bus inputs of the CPU constitute the basic version ofthe system. They are expandable to a total of 28 zones which can be freely associatedto the hard-wired (conventional or bus) or wireless inputs of the connected hardware.The zone programming facilities allow to obtain excellent performances even fromtraditional detectors but the best results are obtained by using the <strong>Tecnoalarm</strong> RDVand RSC detectors. These detectors permit the verification and analysis of the alarmsat the very moment they are released, through the specific diagnostic tools of themonitoring software. In this way, the limitations of traditional remote managementhave been overcome and a new concept of interaction has been proposed.(RDV® and RSC® are registered trademarks and protected by international patents)Wired28Logic28ZonesWireless2881 2 3 4 5ProgramsPrograms and control unitsThe TP8-28 and TP8-28 GSM systems manage 8 programs. A wide range of controlunits is able to satisfy any application requirements. The range comprises theLCD300/S console with voice synthesis, the new LCDPROX1 console with graphicdisplay and transponder reader, RFID card and finger print readers as well as theexclusive TSP7000 STD consoles with 7 inches touch screen and, for the STD-BIOversion, with biometric finger print reader. The users have access to the system’sfunctions through 120 codes, 100 transponders/RFID cards, 80 wireless keys and100 finger prints. Access to the protected areas can be automated and regulatedby 4 access periods and 6 timers.OPERATINGCODESFinger100Trasmitter80Key100Code120AUTOMATICFUNCTIONSAcces Period4Timer6Yearly Calendar2


TECHNICAL AND FUNCTIONAL SPECIFICATIONSZONESOUTPUTSTotal logic zonesCPU hard-wired zonesTotal hard-wired zonesTotal wireless zonesCPU outputsLogic siren outputs282 conventional + 6 bus28282 + 2 programmable4TELEPHONESECTIONTP8-28 GSMChannelsPrimary vectorSecondary vector (optional)Secondary vector (optional)Transmittable eventsTelephone number lengthCall event queue8GSMExternal GSMEthernet12824 digits32RS485 serial busAccording to versionCommunication protocols59SYSTEMFEATURESVoice synthesisEvent buffer capacityPrinter managementAccording to version1500Hard-wired input expansionsWireless expansionsConsoles228PROGRAMSACCESSMANAGEMENTAUTOMATIONProgramsAccess codesFinger printsTransponders/RFIDWireless keysTimersAccess periodsCalendar yearsRemote controlsTest callServer test call8120100100806428SERIAL BUSEXPANSIONSADVANCEDPROGRAMMINGSecondary control unitsOutput expansionsGSM telephone communicatorBus sirensWireless sirensWireless consolesActionsTimersCountersTelephone directoryReserved output expansions8121222128641664TELEPHONESECTIONTP8-28ChannelsPrimary vectorSecondary vector (optional)Secondary vector (optional)Transmittable eventsTelephone number lengthCall event queueCommunication protocols8PSTNExternal GSMEthernet12824 digits32156ELECTRICALSPECIFICATIONSPHYSICALSPECIFICATIONSOperating voltage230V AC +/- 10% 50HzCPU board consumption TP8-28 150mA @ 13.8V DCCPU board consumption TP8-28 GSM 220mA @ 13.8V DCPower supply2A @ 14.8V DCBattery12V/7AhCasingABSDimensions (L x H x D)350 x 285 x 93mmWeight (without battery) TP8-28 (2.7kg) - TP8-28 GSM (2.8kg)CONTROL PANEL VERSIONSApprovalEN 50131-1EN 50131-3Serial BUSConnexionSerial BUSVOCConnexionPSTNInterfaceGSMModuleAdvancedConfigurationPowerA VSupplyABSBoxTP8-28TP8-28 ENTP8-28 GSM/VTP8-28 GSM/V ENFor the itemnumbers pleasecontact theresellerGrade 2Grade 2OptionalOptionalOptionalOptionalOptionalOptionalOptionalOptional2A2A2A2AAll specifications listed in this brochure are subect to change without notice.Via Ciriè, 38 - 10099 San Mauro T.se - Torino (Italy)tel. +390112235410 - fax +390112735590tecnoalarm@tecnoalarm.comwww.tecnoalarm.com495, Rue Antoine Pinay - 69740 Genas - Lyon (France)tél. +33478406525 - fax +33478406746tecnoalarm.france@tecnoalarm.com - www.tecnoalarm.comAgence de Paris: 125, Rue Louis Roche - 92230 Gennevilliersc/Vapor 18 (Pol. Ind. El Regas)08850 Gavá - Barcelona (España)tel. +34936622417tecnoalarm@tecnoalarm.es - www.tecnoalarm.es11-2011 Rev. 0

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!