11.07.2015 Views

Overload Protection Devices English

Overload Protection Devices English

Overload Protection Devices English

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TSBSCS06 TSBSCD TSBSCC0530TSBSCS34 TSBSCD TSBSCC0530TSBSCS60 TSBSCD TSBSCC0530TSBSCB06TSBSCB34TSBSCB60Motor<strong>Protection</strong> functionOutput relayModel No.All-in-one type TSBSCB06 TSBSCB34 TSBSCB60Panel type TSBSCS06 TSBSCS34 TSBSCS604t 0.1kW 200V class2t 0.2, 0.4kW 1.5, 2.2kW Number of wires pass 1t 0.75kW 3.7, 5.5kW 7.5, 11kWthrough the CT hole 4t 0.2kW 400V class2t 0.4, 0.75kW 2.2, 3.7, 5.5kW 1t 1.5kW 7.5, 11kW 15, 18.5, 22kWFrequency of detect current20 200HzMaximum voltage of motor circuitAC690V 50/60HzOperational power source100 240VAC±10%, 50/60HzOvercurrentsettingNumber of wires passthrough the CT hole4t 0.15 1.60A (0.01A) ( ): Increment2t 0.30 3.20A (0.02A) 3.00 17.0A (0.1A) 1t 0.60 6.40A (0.04A) 6.00 34.0A (0.2A) 10.00 60.0A (0.4A)0 12.0s (0.2s and larger: Increment 0.1s)0.2 5.0s (Increment 0.1s)±5% (In case of commercial power source)Start timeShock timeAccuracyCurrent detection accuracyTime detection accuracy ±5%Under currentTrip at 0.2 5s (OFF: No action)Lock when starting upSet at 2 8 times of overcurrent setting value (OFF: No action) Trip after Start time + 0.2s when starting up.Lock when operating Set at 1.5 8 times of overcurrent setting value (OFF: No action), trip at 0.2 5s.Phase-reversalTrip within 0.15s, (OFF: No action)Phase lossTrip at 0.5 5s (OFF: No action)Imbalance Trip at 1 10s (OFF: No action) when setting at 10 50%Alarm Output when A, F and H are set (OFF: No action)Running hourTrip when 10 9990hr is set (OFF: No action)Fail-safeActivated when setting ON (Conducting normally: Excited, Trip: Non-excited)Rated load3A,250VAC cos 1Minimum allowable load *1DC24V, 4mALifeActivation 100,000times at rated loadContact arrangementOC:1c,AL/UC/TO:1aResetSelf-holdingE-r: Manual release or reset of power source, H-r: Only manual releaseAuto-resetA-r: Auto-reset and set the return time at 0.2s 20minAnalog outputAnalog output 4 ~20mA DC Output (OFF: No action) Allowable load resistance: 100 and belowCommunication outputRS485/ModbusInsulation resistance (Between housing-circuit)DC500V 10MDielectric strength Between housing-circuit2000VAC 60Hz 1min.voltageBetween relay contacts1000VAC 60Hz 1min.PlaceIndoor, no water splashAmbient temperature 20 60 °CAmbient humidity30 85%RH (No dew condensation)Altitude2000m and belowAtmosphereNo corrosive gas, oil-mist or dustVibration5.9m/s 2 and belowPower consumption7VA and belowApprox. mass0.3kg and belowUse environment*1: In case inputting the output relay contact to programmable controller (PLC) directly, input through the relay for minute current, because contact failure may happendue to minute current.83

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!