11.07.2015 Views

Overload Protection Devices English

Overload Protection Devices English

Overload Protection Devices English

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ItemModel No.TSM400012 Basic typeTSM4000H12 Economy typeTSM4000H2Load slavedtracking typeTSM4000M1Contactdetection typeTSM4000M2Integral power typeTSM4000C1Built-in forward/reversesequencer typeAppliedmotorCapacity3 Power source voltageFrequency0.1 110kWAC200/220V, AC400/440V5 120HzControl power supply voltageAC90 250V50/60Hz, DC90 250V Nonpolar3 Motor voltageAC250V, MAXInputCurrent sensorDC2.5VControl inputX1, X2, X3, IH, RSTX1, X2, RSTX1, RSTX1, X2, X3, X4, X5X1, X2, X3, X4, X5X1, X2No. of contact3c2c2c3c3c2a, 1b, 1cOutputSettingFunctionDisplayRelay contactoutputOutputrelay lifeMechanicalElectricalAnalog output relayLoadsettinglevelStart time setting rangeShock timesetting rangeReponse4 Inhibit functionRelay self-holdingSwitching detection levelTest functionPeak-holdfunctionOutput 1Output 2Output 3% Power display rangeVoltage display rangeCurrent display rangeFrequency display rangePower consumptionApproximate massAmbienttemperatureReative humidityWorkenvironment AltitudeAmbientatomosphereHigh1 200 200High2 200 200Low 99 99AC250V, 0.5A (Inductive load cos 0.4)DC30V, 0.4A (Inductive load) DC110V, 0.2A (Inductive load) Minimum load applicable DC24V, 4mA10,000,000 activations100,000 activationsDC0 10VHIGH1 1 99 OUT1 1 99HIGH2 5 200 OUT2 1 99 OUT3 5 2000.1 20.0s“MIN” or 0.1 10.0sIn case motor power souce frequency is 50Hz and higher, shock time at “MIN” is approximately 50ms.Set by number ofmoving averageQUICK (Average no. 1 time), NORMAL (Average no. 5 times), SLOW (Average no. 20 times)Manual/auto switchingAutoinhibitSelf-hold/auto reset selectableManual/auto switchingOnly OUT3 is selectableSequencer function8 steps4 stepsNone8 stepsNoneRelay output testWhen the load ratio exceeds the pre-set level (or falls below it), shows the maximum value within shock time. 200 200HIGH1 5 200HIGH2 5 200Only when the output is set as self-hold, it is peak hold.0 2000 500V0.01 999A5 120Hz10VA (Inrush current 5A within 5ms)1.0k0 5045 85% RH; there is no condensation1000m and lessNo corrosive gas, dustOUT1 0 99OUT2 5 200OUT3 5 200<strong>Overload</strong> 5 200No load 5 2001 300s 133

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!